Operating
WARNING:
Before using this outdoor fireplace, make sure you have read, understand and are following all
information provided in the “Safety Information” section beginning on page 2. Failure to follow those instructions
can cause death, serious injury or property damage.
Burner Connections
1, Make sure the valve connections are securely fastened to the burner and the tank.
2, Visually check the connection between the burner / venturi tube and orifice.
3, Make sure the burner/ venturi tube fits over the orifice.
4, Please refer to the diagram for proper installation (Figures 1 and 2).
5, If the burner/venturi tube does not rest flush to the orifice, as shown, please contact 855-600-9294 for assistance.
Tank/Gas Line Connection
1, Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing soap with three parts water.
2, Make sure the regulator/control knob is in the “OFF” position (Figure 3).
3, Apply the leak detection check solution on all “X” locations (Figures 1 and 2).
a. If any bubbles appear, remove the LP gas tank and reconnect, making sure the connection is secure.
b. If you continue to see bubbles after several attempts, remove the LP gas tank per “Disconnecting LP Gas Tank”
section, and contact 855-600-9294 for assistance.
c. If no bubbles appear after one minute,press the control knob and rotate to the “OFF” position, wipe away solution and
proceed.
WARNING:
Failure to inspect this connection or follow these instructions could cause a fire or an explosion which
can cause death, serious bodily injury or damage to property.
Check For Leaks
Figure 1
Figure 2
Figure 3
10
Location Point