background image

 

Tools

required  

Spanner 

 
Silicone 
 
Drill

and

drill

bit  

 
Spirit

Level 

 
Pencil 

Tape

Measure  

Hammer 
 
Screwdriver 
 

 

Installation  

Prepare

the

water

supply pipes

to

feed

the

shower

with

hot

on

the

left

and

cold

on

the

right

,

set

approximately at

the height

and

width

shown

below

.

 

The

supply pipes

should

have

a ½” male

end to connect to the 1.2” female

nut on the flexi

-

pipes 

 

 

 

 

 

 

 

 

 

Before commencing 

installation and

with the 

tray or bath installed

to accept

the

water, turn on the water

supply to

the

water pipes  and

flush

the

system

for

a

minimum

of 15 seconds

,

to

remove

any

debris

in

the

system

.

 

 

1000mm

100

~

150mm

"

ON

Содержание Luni BeBa 28181

Страница 1: ...Please note Image is for illustrative purposes only and may differ slightly to the actual product Multi person assembly Tools required We always recommend using professional tradespeople to install your product V1_26 08 21 Congratulations on your purchase ...

Страница 2: ... Awards UK the Digital Entrepreneur Awards and being placed on The Sunday Times Fast Track 100 We hope your new product goes above and beyond your expectations However should any problems occur please log in to your account and contact our customer services team via your self serve portal betterbathrooms com CustomerAccount Login contact us via betterbathrooms com content contact us Important info...

Страница 3: ...Contents Parts Diagrams P4 Tools required P5 Installation P5 Using P9 Troubleshooting P9 Maintenance P10 Cleaning P12 3 ...

Страница 4: ...Off Control Handle 5 Temperature Control Handle 6 Diverter Valve 7 On Off Cartridge 8 Thermostat inc Stop Ring 9 Temperature Dial 10 Wall Screws x 4 11 12 Wall Hanging Bracket x 2 13 Hand Shower 14 Hose Seals x 2 15 Shower Hose 16 Overhead Bolt x 4 17 Washers x 8 18 Nut x 4 16 17 18 1 2 3 5 9 19 10 6 8 11 20 15 12 14 13 4 7 19 20 Handset Holder and Fi ngs Flexi pipes x 2 Wall Plugs x 4 ...

Страница 5: ...cold on the right set approximately at the height and width shown below The supply pipes should have a male end to connect to the 1 2 female nut on the flexi pipes Before commencing installation and with the tray or bath installed to accept the water turn on the water supply to the water pipes and flush the system for a minimum of 15 seconds to remove any debris in the system 1000mm 100 150mm ON ...

Страница 6: ... If drilling into tile it is recommended to tape the wall to prevent the drill from slipping Drill the wall 35mm deep using a 6mm drill bit Insert the wall plugs and tap flush to the finished wall surface Hold the wall hanging bracket to the wall over the drilled holes and secure using the wall plugs provided 780 50 mm 1000 2 mm 20mm 35mm 6mm 2 3 1 ...

Страница 7: ...ng the seal is fitted connect the pipe which runs from the mixer and which will connect to the holder and tighten the nut Connect the overhead shower to the panel Insert the water pipe from the shower head X 1 2 3 4 5 to shower panel body using the jubilee and tighten onto the outlet using a screwdriver 1 2 3 4 5 Position the shower head onto the panel and align the holes Place a washer onto the bo...

Страница 8: ...ts Fit the seal into the nut end of the shower hose and connect the nut to the outlet on the hand shower holder and tighten if using a spanner place a cloth around the nut to prevent damage Place the second seal into the cone end of the shower hose and connect this to the hand shower and tighten Place the cone of the hose into the holder Installation is then complete the product should then be com...

Страница 9: ...ed water pressure water pressures need to be balanced for correct function 2 Limescale build up or debris in the thermostat this will require cleaning 3 Faulty thermostat 4 Product requires re calibration Water temperature either very cold or very hot no gradual mix 1 This is due to the water supplies being connected to the wrong inlet on the tower these need to be switched so that the correct wat...

Страница 10: ...are not balanced you will need to consult a plumber to either reduce the cold pressure but ensuring the pressure do not fall below the minimum or a pump may need to be installed to balance the pressures 2 To remove the thermostat for cleaning or replacement first turn the shower on then turn off the water supply to the tower by the isolation valves doing this releases the pressure inside the unit b...

Страница 11: ...e valve 3 Using a spanner and taking care not to damage the panel surface remove the retaining nut 4 Once this is removed pull the valve from the panel either clean the valve or replace as necessary 5 Re fit the components and fully tighten the retaining nut to prevent any leaks 1 2 3 4 5 8 9 6 10 11 7 Flat blade screwdriver Plier Allen wrench 2 5 m m ...

Страница 12: ...12 Cleaning To maintain the surface of your product wipe with a clean damp cloth and wipe dry do not use any abrasive cleaning agents or materials It is recommended to wipe and dry on a regular basis ...