9.1 Disassembly Of Handpiece (Continued)
Removal/Disassembly Of The Depth Gauge From The Cover:
Loosen the two attachment screws located inside the depth gauge. It is not necessary to
remove the screws.
Slide the gauge upward until the depth gauge clamps come out of the cover plate grooves.
Removal Of The Blade Housing And Cover:
Loosen cover retaining screws until the
cover is free.
NOTE
:
The screws will stay in the frame.
Remove the blade housing.
Pull the pinion out of the frame.
Attachment Screws
(2)
Cover
Plate Grooves
Depth
Gauge
Clamps
Cover Retaining
Screws (2)
Cover Plate
Pinion
Blade
Housing
Frame
Model 880M2-B