ADJUSTMENTS
AND
INSPECTIONS
GENIE APS
Doc. 10004925
Issued
gen - 07
Rev. 00
Pag.
2 di 2
4. If there are splashes or the water on the floor is not uniform,
check the right position of the water
tube
in the middle of the
brush.
Check the suction system
1. Check the cleaning and functionality of the
filter with ball
.
2. Check, if closed, the tightness of the
cap
of the recovery tank,
verifying the good wear of the
gaskets
of the muffs.
3. Check the right position and tightness of the
muffs
on the
recovery tank cap.
4. check the good wear of the squeegee rubber and the good
tightness of the
knobs
of the squeegee support
5. If the squeegee lifts when it turns try to unscrew the
nut
of the
squeegee spring to set it lightly free. The standard position is at
thread.
6. Verify that there is a little clearance
Final test