Beta Presto Spectro Скачать руководство пользователя страница 8

Trapping is the result of solid yellow, magenta, and cyan 
inks printed in two color combinations to produce red, 
green and blue solids.  
Trapping efficiency is the ability of the second color to be 
accepted or trapped by the first color.
Measure overprint target (for example Red, composed of 
Magenta and Yellow)

Matching the color sequence is necessary to match 
previous print jobs.

Measure Magenta or Yellow

Measure the second color 

Open Trap Screen and 

measure Trap Color

See first and second color

 sequence and % efficiency

TRAPPING

8

13

Increase highlighted value (L,a,b)        Decrease value
Select next value (L,a,b)        Return to calibration mode 

 

FLASHING LED’S

ABSOLUTE WHITE CALIBRATION

 

FLASHING LED’S

DENSITY CALIBRATION

Measure 

the white 

Lab 

plaque

4

3

2

1

Press Key A - Zero to paper.
Measure  solid Cyan, Magenta, 
Yellow or Black from a 
Calibration Chart

Adjust each Density to agree 
with Calibration Chart.
Increase Density
Decrease Density

1.Open the PRESTO Screen 
by holding Key A and then 
press Key D
2. Press Key B
3. Press Key C 2X

Содержание Presto Spectro

Страница 1: ...ing index DIGITAL MICROMETERS Precise measurements of paper plates blankets and packing Display 0 0005 in or 0 01mm Spring loaded anvil assures accuracy PRECISION RULERS Precise non contact m e a s u r e m e n t o f distancesonfilms plates dies prints Available as Electronic Ruler or Video Ruler BETAFOLD CREASE FOLD ANALYZER Portable hand held analysis of crease height width angles and symmetry 7 ...

Страница 2: ...gets of solid yellow magenta cyan black and gray balance appear in every ink zone for ultimate control across the full width of the sheet Trapping dot gain and resolution targets are centered for smallersheets CMYK and Gray Balance appear in every ink zone 50 and Gray Balance appear every 4th zone RESOLUTION TARGETS WITH MICRO DOTS of 1 2 3 and 5 minimum printable dot targets detect press slur and...

Страница 3: ...Dot Gain Measurements 5 Balance Mode 7 MGM Magic Color Match 8 Trapping 8 Color Mode 9 Select Delta E Calculations Formula 9 Color Reference Library 10 Edit Density Tolerances 11 Edit Dot Gain Tolerances 12 Edit Gray Balance Tolerance 13 Absolute White Calibration 13 Density Calibration 13 Certification Reset 14 Select Delta E Calculation Formula 14 Select Color Space 14 Select USB Output Format 1...

Страница 4: ...ture or in the new exclusive with Lab COLOR REFERENCE LIBRARY Delta E that stores up to 32 colors in 4 separate channels for fast accurate AUTO color matching Ideal for Flexo To start open the AUTO MODE screen and Zero to paper Measure DENSITY DOT GAIN and DOT AREA Press KEY D to advance to the other programs GETTING STARTED There are 4 Primary Screens Automatic Density Balance Trapping Color 17 T...

Страница 5: ... T PRESTO SPECTRO instruments are delivered with 25 50 and 75 Dot Gain target values Status E instruments are set at 25 40 and 80 These set points can be changed in the Configuration Mode 5 AUTO Mode DENSITY In AUTO MODE measure DENSITY DOT GAIN and DOT AREA The unit will automatically ZERO to paper with a DENSITY lower than 0 15D RELATIVE DENSITY MODE with MM Magic Memory ZERO to paper or press a...

Страница 6: ...interpreted as a high Dot Gain target If this occurs Zero to paper and measure any questionable DENSITY target again 15 OPTIONAL COLOR LIBRARY SOFTWARE PrestoConnect Color Library Management Software The optional PrestoConnect Windows software allows the user to create collect and manage an unlimited number of colors in conjunction with the new Beta Presto Spectro portable spectrodensitometer The ...

Страница 7: ...r space Select CIE LCh color space Select next main configuration function Exit SELECT COLOR SPACE Measure any Gray Balance Patch 3 without pressing any Keys The display arrow will indicate the greatest difference and direction followed by the remaining colors Select ALL Output format Select DX Output format Move to next main configuration function Exit the configuration mode CERTIFICATION RESET S...

Страница 8: ... the second color Open Trap Screen and measure Trap Color See first and second color sequence and efficiency TRAPPING 8 13 Increase highlighted value L a b Decrease value Select next value L a b Return to calibration mode FLASHING LED S ABSOLUTE WHITE CALIBRATION FLASHING LED S DENSITY CALIBRATION Measure the white Lab plaque 4 3 2 1 Press Key A Zero to paper Measure solid Cyan Magenta Yellow or B...

Страница 9: ...LECT REFERENCE SAMPLE MEASUREMENTS L 100 L 100 L 100 L 0 L 0 L 0 a a a a a a b b b b b b Level 1 Level 1 2 0 dE 2000 the most color critical applications 3 0 dE 2000 color critical applications e g Level 2 Level 2 4 5 dE 2000 pleasing process color printing Level 3 Level 3 6 0 dE 2000 non critical color Level 4 Level 4 Level 1 2 0 dE 2000 the most color critical applications 3 0 dE 2000 color crit...

Страница 10: ...A B C D each with 8 Colors The AUTO Mode will recognize each of the 8 colors within the 4 Sections when a sample is measured For example Section A is CMYK plus RGB Gray Balance or spot color Section B is CMYK plus OGV and White ink Section C and D are any random colors on a print job Suggested values If the selected Volume is empty SPECTRO Mode will open as shown here Press Key C to open the Libra...

Отзывы: