Gray Balance Targets are composed of Yellow, Magenta and 
Cyan tints balanced to produce a neutral gray when all the 
pre-press conditions are in control. 
Making press corrections for slurring, doubling, ink water 
imbalance, etc. are fast and easy with ink key adjustments 
without stopping the press or wasted paper or downtime.

   GRAY BALANCE MODE 

Y=40%

M=40%

C=50%

K=50%

For Visual 

Comparison

7

14

SELECT USB OUTPUT FORMAT

Select Delta E1976 (not 
recommended except for 
compatibility)
Select Delta E2000 (the current 
international standard)

Select next  configuration        
Exit

SELECT DELTA E CALCULATION FORMULA

E

Select CIE Lab color space
Select CIE LCh color space
Select next main configuration 
function
Exit 

SELECT COLOR SPACE

  .Measure any Gray Balance Patch 

3

without pressing any Keys.          
The display arrow will indicate the 
greatest difference and direction 
followed by the remaining colors.           

        Select ALL Output format

         Select DX Output format
 

Move to next main configuration function
Exit the configuration mode

CERTIFICATION & RESET

Select the calibration mode 
to check the calibration date.
Click the Factory Setting Icon 
Key to reset all settings

Balance Tolerance can be changed 
up to 7.0 dE.The factory default dE is 
5.0  Edit instructions are on page 13. 

     .Open BALANCE MODE

1

2

.Zero  a 50% Black 

tint or an OK sheet 
CMY Balance patch 
with Key A.  

NOTE

: The LED’s will flash 

 when measurements

GREEN

  are within dE 5.0 or 

 when out of TOLERANCE.

RED

1

2

3

B A L

5 0 %

Содержание Presto Spectro

Страница 1: ...ing index DIGITAL MICROMETERS Precise measurements of paper plates blankets and packing Display 0 0005 in or 0 01mm Spring loaded anvil assures accuracy PRECISION RULERS Precise non contact m e a s u r e m e n t o f distancesonfilms plates dies prints Available as Electronic Ruler or Video Ruler BETAFOLD CREASE FOLD ANALYZER Portable hand held analysis of crease height width angles and symmetry 7 ...

Страница 2: ...gets of solid yellow magenta cyan black and gray balance appear in every ink zone for ultimate control across the full width of the sheet Trapping dot gain and resolution targets are centered for smallersheets CMYK and Gray Balance appear in every ink zone 50 and Gray Balance appear every 4th zone RESOLUTION TARGETS WITH MICRO DOTS of 1 2 3 and 5 minimum printable dot targets detect press slur and...

Страница 3: ...Dot Gain Measurements 5 Balance Mode 7 MGM Magic Color Match 8 Trapping 8 Color Mode 9 Select Delta E Calculations Formula 9 Color Reference Library 10 Edit Density Tolerances 11 Edit Dot Gain Tolerances 12 Edit Gray Balance Tolerance 13 Absolute White Calibration 13 Density Calibration 13 Certification Reset 14 Select Delta E Calculation Formula 14 Select Color Space 14 Select USB Output Format 1...

Страница 4: ...ture or in the new exclusive with Lab COLOR REFERENCE LIBRARY Delta E that stores up to 32 colors in 4 separate channels for fast accurate AUTO color matching Ideal for Flexo To start open the AUTO MODE screen and Zero to paper Measure DENSITY DOT GAIN and DOT AREA Press KEY D to advance to the other programs GETTING STARTED There are 4 Primary Screens Automatic Density Balance Trapping Color 17 T...

Страница 5: ... T PRESTO SPECTRO instruments are delivered with 25 50 and 75 Dot Gain target values Status E instruments are set at 25 40 and 80 These set points can be changed in the Configuration Mode 5 AUTO Mode DENSITY In AUTO MODE measure DENSITY DOT GAIN and DOT AREA The unit will automatically ZERO to paper with a DENSITY lower than 0 15D RELATIVE DENSITY MODE with MM Magic Memory ZERO to paper or press a...

Страница 6: ...interpreted as a high Dot Gain target If this occurs Zero to paper and measure any questionable DENSITY target again 15 OPTIONAL COLOR LIBRARY SOFTWARE PrestoConnect Color Library Management Software The optional PrestoConnect Windows software allows the user to create collect and manage an unlimited number of colors in conjunction with the new Beta Presto Spectro portable spectrodensitometer The ...

Страница 7: ...r space Select CIE LCh color space Select next main configuration function Exit SELECT COLOR SPACE Measure any Gray Balance Patch 3 without pressing any Keys The display arrow will indicate the greatest difference and direction followed by the remaining colors Select ALL Output format Select DX Output format Move to next main configuration function Exit the configuration mode CERTIFICATION RESET S...

Страница 8: ... the second color Open Trap Screen and measure Trap Color See first and second color sequence and efficiency TRAPPING 8 13 Increase highlighted value L a b Decrease value Select next value L a b Return to calibration mode FLASHING LED S ABSOLUTE WHITE CALIBRATION FLASHING LED S DENSITY CALIBRATION Measure the white Lab plaque 4 3 2 1 Press Key A Zero to paper Measure solid Cyan Magenta Yellow or B...

Страница 9: ...LECT REFERENCE SAMPLE MEASUREMENTS L 100 L 100 L 100 L 0 L 0 L 0 a a a a a a b b b b b b Level 1 Level 1 2 0 dE 2000 the most color critical applications 3 0 dE 2000 color critical applications e g Level 2 Level 2 4 5 dE 2000 pleasing process color printing Level 3 Level 3 6 0 dE 2000 non critical color Level 4 Level 4 Level 1 2 0 dE 2000 the most color critical applications 3 0 dE 2000 color crit...

Страница 10: ...A B C D each with 8 Colors The AUTO Mode will recognize each of the 8 colors within the 4 Sections when a sample is measured For example Section A is CMYK plus RGB Gray Balance or spot color Section B is CMYK plus OGV and White ink Section C and D are any random colors on a print job Suggested values If the selected Volume is empty SPECTRO Mode will open as shown here Press Key C to open the Libra...

Отзывы: