EN

TORQUE MEMORIES MENU

• This menu provides the values of the measured and stored torque or angle (up to 50 values stored).

• If no values have been stored in the menu, the display will show nonE.

• The display will show the stored torque value for each memory area (n005<--> 20.3°).

• Press buttons       and        to select the stored values. 

• To delete one of the stored values, press button (C) twice in the memory area.

• To quit the menu, press button (U/S) several times.
RESETTING TORQUE MEMORIES MENU

• This function allows all the values stored in the TORQUE MEMORIES menu to be deleted.

• The display will show ClrA

• To delete all the stored values, press button (C): the display will show no?

• To delete all the stored values, press button (C) again. To cancel the operation, press button (U/S).

• To quit the menu, press button (U/S) several times.
TIGHTENING COUNT MENU

• The device will store the torque at a torque value equal to, or higher than, 60% of its maximum capacity.

• The count cannot be reset until the next calibration.

• For example, if the display shows (n-0 <--> 0160) , it means that 160 torque values have been set.

  If it shows (n-1 <--> 2500), it means that 12,500 torque values have been set.

• To quit the menu, press button (U/S) twice.
ERROR MESSAGES

• Er0 > indicates that the gauge has been subjected to a driving torque higher than 110% of the maximum

  value.

• Er4 > indicates that the value has not been set correctly. Press button (C) to repeat the operation. 

   Do not move the gauge while setting it.

• Er5 > indicates that the gauge is not working correctly. Proceed with the RESET.

• Er---> indicates that the gauge was rotated too quickly during a measurement. Press button (C) to repeat 

   the operation.

• Full > indicates that no data can be stored in the memory because the memory is full. Delete some 

  of the 50 stored data.
RESET

• The gauge can be reset by removing the batteries.
MAINTENANCE

Maintenance, repair and calibration jobs must be carried out by trained personnel only. For such jobs, 

you can contact Beta Utensili S.P.A.’ s repair centre. 
DISPOSAL

The crossed-out wheelie bin symbol on the equipment or packaging means that the product should be 

collected separately from other types of urban waste at the end of its useful life.

Any user who is going to dispose of this tool can:

• deliver it to an appropriate collection facility for electronic and electrotechnical equipment;

• return it to the dealer upon purchase of a new, equivalent item of equipment;

• in case of a product for professional use only, contact the manufacturer which will arrange for the 

product to be properly disposed of.

Proper disposal of this product allows the raw materials contained in it to be reused and prevents da-

mage to the environment and human health.

Illegal disposal of this product is a violation of the provision concerning the disposal of hazardous waste 

and will give way to the application of such fines as provided for under current regulations.

>

>

601CA.indd   10

08/09/16   10:54

Содержание 601CA

Страница 1: ... ISTRUZIONI PER L USO I INSTRUCTIONS FOR USE EN MODE D EMPLOI F GEBRAUCHSANWEISUNG D INSTRUCCIONES E INSTRUÇÕES DE USO PT GEBRUIKSAANWIJZING NL INSTRUKCJA OBSŁUGI PL h e f d a b c 601CA indd 1 08 09 16 10 54 ...

Страница 2: ...he digital gauge must not be used for any applications other than recommended ones WORK AREA SAFETY Do not operate the digital gauge in environments containing potentially explosive atmospheres because sparks may be generated which can ignite the dust or fumes Keep children away from the digital gauge Do not use the digital gauge near flammable material DIGITAL GAUGE SAFETY Before use check that t...

Страница 3: ...ts Do not place the digital gauge near magnetic fields Do not modify the digital gauge Changes may affect operation TECHNICAL DATA KEY TO SYMBOLS a LED indicators b buzzer c digital display d start of measurement menu button C e unit selection button U S f pulsante memoria M f memory button M button button h battery compartment DISPLAY PRECISIONE ANGOLO TORQUE MEASURING RANGETORQUE ACCURACY RESOLU...

Страница 4: ...tightening process is resumed the value will be calculated from the value reached before To reset the device and start a new measurement press button C If the device is not used for approximately 2 minutes the device will automatically turn off SETTING UP MENU Press button C to turn the gauge on Keep button U S pressed to enter the configuration menu Press button U S several times to enter the men...

Страница 5: ...he value has not been set correctly Press button C to repeat the operation Do not move the gauge while setting it Er5 indicates that the gauge is not working correctly Proceed with the RESET Er indicates that the gauge was rotated too quickly during a measurement Press button C to repeat the operation Full indicates that no data can be stored in the memory because the memory is full Delete some of...

Страница 6: ...ot cover defects due to wear misuse or breakdowns caused by blows and or falls In addition this warranty will no longer be valid if any changes are made or if the digital gauge is forced or sent to the customer service in pieces This warranty explicitly excludes any damage to people and or things whether direct or consequential We hereby declare assuming responsibility that the described product c...

Отзывы: