the up, down, left, right direction keys and "Enter" key to set frequency parameter,
select "OK" and press "Enter" button to confirm.
4. Set offset
Press
F4
button to enter the second page. Press
F2
to select
Offset
, then use the up,
down, left and right direction keys to adjust the frequency, press
F2
button to open the
digital keyboard again, use the up, down, left, right direction keys and "Enter" key to
set frequency parameter, select "OK" and press "Enter" button to confirm.
5. Set duty cycle
enter the second page. Press
F3
to select
Duty
, then use the up, down, left and right
direction keys to adjust the frequency, press
F3
button to open the digital keyboard
again, use the up, down, left, right direction keys and "Enter" key to set frequency
parameter, select "OK" and press "Enter" button to confirm.
6. Generate an arbitrary waveform
It is necessary to edit the arbitrary waveform in connection with the software and
download it into the machine. There are 4 arbitrary wave positions, and each position
can permanently store an arbitrary wave.
7. After setting the waveform parameters, press the
button to turn on or off the signal
output. The output waveform of the signal generator can be observed through an
oscilloscope.
Output the sine waveform
Output a sine waveform with 10KHz/2.5Vpp as follows:
1. Press
AWG
button to enter the waveform generator function interface.
2. Press
F1
to select “Sine”;
3. Frequency: First press
F2
button to select
Frequency
, then use the up, down, left
and right direction keys to adjust the frequency. Second press
F2
button to open the
digital keyboard again, use the up, down, left, right direction keys and "Enter" key to
set frequency parameter, select "OK" and press "Enter" button to confirm. Set the
frequency to 10KHz;
4. Amplitude: First press
F3
button to select
Amplitude
, then use the up, down, left and
right direction keys to adjust the amplitude. Second press
F3
button to open the
digital keyboard again, use the up, down, left, right direction keys and "Enter" key to
set amplitude parameter, select "OK" and press "Enter" button to confirm. Set the
amplitude to 2.5V;
5. Offset: Press
F4
to enter the second page. First press
F1
button to select
Offset
,
then use the up, down, left and right direction keys to adjust the offset. Second press
F1
button to open the digital keyboard again, use the up, down, left, right direction
72
Содержание 1760DGT/2
Страница 1: ...1760DGT 2 Multimetro digitale con oscilloscopio Manuale d uso 1 ...
Страница 44: ...1760DGT 2 Digital multimeter with oscilloscope User Manual 44 ...
Страница 75: ...8 Connect Gen Out connector to oscilloscope for observation 75 ...
Страница 85: ...1760DGT 2 Multimètre numérique avec oscilloscope Manuel de l Utilisateur 85 ...
Страница 117: ...8 Connectez le connecteur Gen Out à l oscilloscope pour l observation 117 ...
Страница 127: ...1760DGT 2 Digitalmultimeter mit Oszilloskop Benutzerhandbuch 127 ...
Страница 159: ...8 Schließen Sie den Gen Out Stecker zur Beobachtung an das Oszilloskop an 159 ...
Страница 169: ...1760DGT 2 Multímetro digital con osciloscopio Manual de usuario 169 ...
Страница 200: ...8 Conecte el conector Gen Out al osciloscopio para observación 200 ...
Страница 210: ...1760DGT 2 Multímetro digital com osciloscópio Manual do usuário 210 ...
Страница 241: ...8 Conecte o conector Gen Out ao osciloscópio para observação 241 ...
Страница 251: ...1760DGT 2 Digitale multimeter met oscilloscoop Handleiding 251 ...
Страница 282: ...8 Sluit de Gen Out connector aan op de oscilloscoop voor observatie 282 ...
Страница 292: ...1760DGT 2 Multimetr cyfrowy z oscyloskopem Instrukcja obsługi 292 ...
Страница 323: ...8 Podłączyć złącze Gen Out do oscyloskopu w celu obserwacji 323 ...
Страница 333: ...1760DGT 2 Digitális multiméter oszcilloszkóppal Használati utasítás 333 ...
Страница 365: ...8 Csatlakoztassa a Gen Out csatlakozót az oszcilloszkóppal megfigyelés céljából 365 ...