Operators 

Maintenance

 Manual

Control Panel D - Digital

Operators 

Maintenance

 Manual

Control Panel D - Digital

Содержание D Panel

Страница 1: ...Operators Maintenance Manual Control Panel D Digital Operators Maintenance Manual Control Panel D Digital...

Страница 2: ...RPM engine temperature oil pressure and provides a voltmeter for either single or twin alternators The panel uses standard Micro C connection which allows data to be relayed and viewed all across your...

Страница 3: ...ine starts No more than 3 seconds as this could damage the starter motor STOPPING 1 Press the STOP button until the engine stops This should not be more than 5 seconds 2 Switch off the POWER switch An...

Страница 4: ...y to the night screen 2 This button displays water temp oil pressure and battery voltage If you have a second alternator fitted this will display domestic battery as well Pressing a second time will c...

Страница 5: ...the normal digital dashboard Press button 1 to scroll up or 2 to scroll down the screen to highlight CONFIG menu options SETTINGS When highlighted in a yellow bar pressing button 4 allows access to t...

Страница 6: ...pressing the right arrow button 3 the engine calibration is updated and saved automatically Alternatively calibration can be manually set without the engine running by pressing buttons 1 or 2 to achi...

Страница 7: ...ng button 4 allows you to enter the full Units menu Using buttons 1 2 scroll up or down the screen to highlight each Units menu option When highlighted as a yellow bar engine temperature measurement m...

Страница 8: ...l increase the value Once all new values has been set pressing button 5 will save exit return to the SETTINGS menu Pressing button 5 once more returns to the CONFIG menu pressing once more returns to...

Страница 9: ...installed on the D Panel Beta Marine conducts continuous product development and reserves the right to change design specification and functionality It is recommended that from time to time you contac...

Страница 10: ...5 2 Beta 30 5 8 Beta 35 4 3 5 8 Beta 38 5 5 Beta 43 5 2 5 8 3 7 Beta 45 Beta 50 4 2 Beta 60 4 9 5 8 4 3 Beta 70 Beta 75 4 6 Beta 85 Beta 90 4 6 Beta 105 Beta 150 Calibration Factor Calculation To calc...

Страница 11: ...update the current engine hours must be recorded Please refer to CONFIG MENU section of this manual To ensure you software is up to date please email spares betamarine co uk or telephone 44 0 1452 723...

Страница 12: ...gine battery and remove the USB stick connection lead Then switch back on and check the display is functioning correctly Fig 7 before finally switching off the display and switch off isolate engine ba...