SAFETY  INSTRUCTIONS

WARNING

IMPORTANT SAFETY INSTRUCTIONS 

When installing and using this electrical equipment, basic safety precautions should always be followed, 

including the following:

READ AND FOLLOW ALL INSTRUCTIONS

  

WARNING -

 

TO REDUCE THE RISK OF INJURY -

 

do not permit children to use this product unless they are closely 

supervised at all times.

  

WARNING -

 

RISK OF ELECTRIC SHOCK -

 Connect only to a grounding type receptacle. This product is provided with a 

ground-fault circuit-interrupter. If replacement of the plug is needed, use only identical replacement parts.

 

 

WARNING -

 

The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI,push the test button. The 

GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is 

defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the 

possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified service 

representative before using.

  

CAUTION -

 

To reduce the risk of electric shock the pool must be installed no closer than 6 feet (1.8 m) from any electrical 

outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool.

  

DO NOT BURY CORD -

 

Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.

  

WARNING -

 

To reduce the risk of electric shock, replace damaged cord immediately.

  

WARNING -

 

To reduce the risk of electric shock, do not use extension cord to connect unit to electric supply; provide a 

properly located outlet.

  

CAUTION:

 

This pump is for use with storable pools only. Do not use with permanently-installed pools. A storable pool is 

constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A 

    permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.

   Please examine and verify all sand filter components are present before use. Notify Bestway at the customer service address listed on 

this manual for any damaged or missing parts at the time of purchase.

  

•THERMALLY PROTECTED MOTOR. CSA ENCLOSURE 3

  • FOR USE WITH SWIMMING POOLS ONLY.

  

• 

CAUTION:

 

TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD,USE ONLY IDENTICAL

      REPLACEMENT PARTS WHEN SERVICING.

  

• 

WARNING:

 

RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING TYPE RECEPTACLE.

  

• 

CAUTION:

 

THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO NOT USE WITH PERMANENTLY-INSTALLED

      POOLS.

  

• 

CAUTION:

 

CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND FAULT  

      CIRCUIT INTERRUPTER.

  

• 

CAUTION:

 

FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED

      TO THE BASE IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.

  

• 

WARNING -

 

RISK OF ELECTROCUTION

  

1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin.

  2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.

  3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground.

  4) Do Not Touch Plug With Wet Hands.

  5) Double Insulated – When Servicing Use Only Identical Replacement Parts.

  6) Read Instruction Manual Before Using.

  

DO NOT REMOVE THIS TAG

  

SAVE THESE INSTRUCTIONS.

Содержание FLOWCLEAR 58401E

Страница 1: ...CON FILTRO DE ARENA CON BOMBA EL CTRICA CALENTADOR SOLAR Y ACCESORIOS Caracter sticas El ctricas 110V 120V 60Hz 2 4A Marca Power Steel ITM ART 1179351 Modelo 15159 Hecho en China Importado por Import...

Страница 2: ...extensi n para conectar la unidad al suministro el ctrico sit e una toma en un lugar adecuado PRECAUCI N Este bomba puede usarse s lo con piscinas que se guardan No lo use con piscinas instaladas de...

Страница 3: ...r el funcionamiento operaciones de mantenimiento y protecci n durante el invierno 3 Antes de su uso el filtro de arena debe fijarse verticalmente sobre el suelo o sobre una base de madera o cemento pa...

Страница 4: ...00gal JS YF 2017 B 01008 Nut Tuerca Nut MAX MIN 20 0 45mm 0 85mm C C C C Conexi n a la piscina Para conexiones de 38mm 1 5 pul 2 1 A B B A B A B A B A D B B 2 3 1 D Manguera de jard n no incluida Para...

Страница 5: ...ntacte con su servicio posventa Bestway local GFCI Test RESET TEST A B C RESET TEST D RESET TEST A B B B 3 4 A B B VISTA GENERAL DE LA V LVULA DE CONTROL ATENCI N Para evitar da os al equipo o heridas...

Страница 6: ...er a la piscina C B D A Aclarado Esta funci n se usa para el inicio limpieza y nivelado del lecho de arena despu s del retrolavado se bombea el agua hacia abajo a trav s del lecho de arena a trav s de...

Страница 7: ...echo de arena siga lasinstrucciones previamente indicadas en la Retrolavado y aclarado NOTA 1 El Man metro se usa solo para medir la presi n del agua no como instrumento de precisi n 2 Le recomendamos...

Страница 8: ...que ha comprado viene acompa ado de una garant a limitada Bestway asevera nuestra garant a de calidad y asegura mediante una garant a de sustituci n que su producto estar libre de defectos de fabricac...

Страница 9: ...P S 005168 P S 005168 21 0x28 5cm 58401E 1000gal JS YF 2017 B 01008 58401E FLOWCLEAR SAND FILTER OWNER S MANUAL www bestwaycorp com Visit Bestway YouTube channel...

Страница 10: ...ARNING To reduce the risk of electric shock do not use extension cord to connect unit to electric supply provide a properly located outlet CAUTION This pump is for use with storable pools only Do not...

Страница 11: ...essible for operation servicing and winterizing 3 The sand filter must be vertically fixed on ground or a certain pedestal made of wood or concrete before use to prevent the sand filter from accidenta...

Страница 12: ...0x28 5cm 58401E 1000gal JS YF 2017 B 01008 Nut Nut Nut MAX MIN 20 0 45 0 85mm C C C C Connect to the pool For 1 5in 38mm connection 2 1 A B B A B A B A B A D B B 2 3 1 D Garden hose not included For D...

Страница 13: ...SHOCK THE GFCI MUST BE TESTED BEFORE EACH USE WARNING DO NOT USE THE PUMP IF THE ABOVE TEST FAILS Please contact your local Bestway Aftersales Service GFCI Test RESET TEST A B C RESET TEST D RESET TES...

Страница 14: ...out of Port D C B D A Drain This function drains water from the pool another filter bypass setting water is pumped and deposited out of Port D instead of returning it to the pool C B D A Rinse This fu...

Страница 15: ...is too low it is time to clean the sand To clean the sand bed follow all instructions outlined previously in Backwash and Rinsing NOTE 1 The Pressure Gauge is just used for measuring the water pressur...

Страница 16: ...Please copy the Batch Number found on the body of the sand filter The product you have purchased comes with a limited warranty Bestway stands behind our quality guarantee and assures through a replace...

Отзывы: