8
SEtUP & InStaLLatIOn
L
M
n
O
P
2
1
StEP
3
StEP
StEP
Red Tubing
Compression Nut
Compression Nut
3/8” T Valve
Cold Water
Supply Line
Cold Water
Supply Line
Red Tubing
(
from 3/8” T Valve)
Inlet Connector
Outlet Connector
System Installation:
1. Using the 5/8” open ended wrench, unthread the compression
nut located on top of the shut-off valve located on existing cold
water supply line.
(fig . L)
2. Thread the 3/8” T Valve onto cold water supply line, and tighten
with the 5/8” open ended wrench
(fig . M, Step 1)
. Next, thread
the compression nut onto the top of 3/8” T Valve and tighten
(fig . M, Step 2)
. Lastly, press the Red Tubing into the Outlet Connector
located on 3/8” T Valve
(fig . M, Step 3)
.
3. Press opposite end of Red Tubing into Inlet Connector located on
top of Lid Assembly.
(fig . n)
4.
UCt100 MODELS:
Push the Blue Tubing from the System Faucet
into the Outlet Connector located on top of Lid Assembly.
(fig . O)
(Skip to instruction number 8.)
UCt200 MODELS (with Filter Life Indicator):
Locate an area on
cabinet wall to mount the Filter Life Monitor. Secure Filter Life
Monitor to the wall using the Velcro Adhesive Strips provided.
(fig . P)
Important
Before attempting this installation, be certain to turn “OFF” the cold water supply
located under your sink . If a shut-off valve is not located on the cold water line
directly under your kitchen sink, shut off the main water supply to your home .
reCommenDatIon
you may want to reduce the length of the red tubing if you find there is excess .
however, it is advisable to leave the red and Blue tubing long enough so that
the System can be easily removed from under the counter when it’s time to
replace the Cartridge .
CautIon
Use a sharp knife when cutting tubing . take extra care not to distort tubing
while cutting . Cut tubing end straight . Failure to do so may result in leaking .
note
Locate an area under the kitchen sink to place the Base . the Base should be
located directly under the area where the Faucet will be installed .
note
If you find that it is necessary to remove the tubing from Inlet or Outlet Connectors,
depress the small collar located on the Inlet and Outlet Connectors and pull
tubing upward at same time .
Blue Tubing
(from System Faucet)
Velcro Strip
(on cabinet wall)
Filter Life
Monitor