13
It is only and used to distinct from the ID of other domes.
CHECK ID
Distinguishing several domes with same ID and altering target ID, soft protocol and baud rate
need to enter check ID in line with the device ID, otherwise altering can’t be completed.
TARGET ID
Target ID is available from 001 to 250.
SOFT PROTOCOL
Soft protocol is auto, Pelco-D and Pelco-P available
BAUD RATE
1200BPS
、
2400BPS
、
4800BPS
、
9600BPS available
COMM RESET
As shown in fig 4.3.3.2, carry out YES to reboot the dome and communication reset to DIP set
hard ID and hard baud rate.
SAVE
Please save the change of communication. After saving, the dome will reboot.
Remark:
The out-of-factory default of dome camera is hardware DIP set. After the COMM. is
changed in menu, it can’t be effective until saved. If needing to get hardware DIP set again, run
the COMM RESET.
4.3.2 Guard Tours
Fig 4.3.2.1 Fig 4.3.2.2
GUARD TOUR
Total 3 guard tours selectable: 01, 02, 03.
<GUARD TOURS>
GUARD TOUR
01
<SETTING>
INIT
RUNNING
DELETE
EXIT
<GUARD TOUR 01>
ID POINT TIME(S) SPEED
1 01 06 64
2 02 06 64
3 03 06 64
4 04 06 64
5 05 06 64
6 06 06 64
7 07 06 64
8 08 06 64