b. Follow all safety requirements as referenced under IMPORTANT SAFETY INSTRUCTIONS
on Page 2.
3. After the area is prepared and the floor is clean and level, the tub can be moved into place.
PREPARING THE AREA
1. Remove the existing tub and the wall and floor materials as required.
2. Have a licensed electrician install the power supply per the requirements of the National Electrical
Code and the local authority having jurisdiction as shown on pages 12 & 13.
USA - a. If the unit is equipped with only one pump or blower, it requires one circuit rated
15Amp/120Volt which is properly grounded and protected by a suitable
“Ground-Fault Circuit-Interrupter” (GFCI) and a circuit breaker.
b. If the unit is equipped with both a pump and a blower, each of these requires a circuit
rated 15Amp/120Volt or one 30Amp/120Volt, properly grounded and protected by a
suitable “Ground-Fault Circuit-Interrupter” (GFCI) and a circuit breaker.
CANADA - a. If the unit is equipped with only one pump or blower, it requires one circuit rated not
more than 15Amp/125Volt which is properly grounded and protected by a suitable
Ground Fault Circuit Interruptor (GFCI) and a circuit breaker.
CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER;
CONNECT ONLY TO A BRANCH CIRCUIT PROTECTED BY AN OVERCURRENT PROTECTION DEVICE
RATED NOT MORE THAN 15 A.
BRANCHER SEULEMENT À UNE DÉRIVATION PROTÉGÉE PAR UN DISJONCTEUR DE FUITE À LA
TERRE DE CLASSE A; BRANCHER À UNE DÉRIVATION PROTÉGÉE PAR UN DISPOSITIF DE
PROTECTION CONTRE LES SURINTENSITÉS D'AU PLUS 15 A.
b. If the unit is equipped with both a pump and a blower, a 30Amp/125Volt properly
grounded and circuit breaker-protected line must be hard-wired into the factory
installed junction box.
CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER;
CONNECT ONLY TO A BRANCH CIRCUIT PROTECTED BY AN OVERCURRENT PROTECTION DEVICE
RATED NOT MORE THAN 30 A.
BRANCHER SEULEMENT À UNE DÉRIVATION PROTÉGÉE PAR UN DISJONCTEUR DE FUITE À LA
TERRE DE CLASSE A; BRANCHER À UNE DÉRIVATION PROTÉGÉE PAR UN DISPOSITIF DE
PROTECTION CONTRE LES SURINTENSITÉS D'AU PLUS 30 A.
INSTALL THIS UNIT IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE, PART 1
INSTALLER CONFORMEMENT AU CODE CANADIEN DE L'ELECTRICITE, PREMIERE PARTIE
PREPARING THE TUB
1. Install the plumbing rough-in on the deck (unless factory installed). For easier access to plumbing,
an additional access hole may be cut out of the side in an ALCOVE or CORNER installation:
- See pages 12-13 for cutting dimension limitations. Use a skillsaw to make the cut. Adjust
the foot of the saw to the thickness of the material (approx. 5/8" to 1") to ensure that you
don't harm any existing plumbing (if factory/already installed).
2. For ALCOVE and CORNER installations, you must attach the flange(s) to the side(s) of the tub on
any side that will be against framing.
a. Lay a bead of silicone on either the flange or on the tub where the flange will be attached.
b. Next, screw the nailing flange(s) to the tub.
c. Place the foil tape on the outside corner to continue the back nailing flange.
d. Lay one final bead of silicone to the joint of the tub and nailing flange.
3. Install the waste/overflow assembly and connect the door drain fitting to the drain.
The BigE model XTWJ6035
Walk-In Tub Installation and Operating Instructions
BigE Walk-In Tub USA/CANADA 2010 Page 4 of 14