Filling the water tank: 

  

Before you operate the Air Purifier please fill the water tank up to the water Level mark 

with cold clear water. To do this always switch off the air purifier and unplug the plug 
from the socket. See the illustrations and descriptions below.  

 

 
 
 
 
 
 
 
 
 
 

Re-mount the front cover 
  
 

 
 
The Air Purifier is fitted with timer-based water level monitor which advises you when to 

review the water level. The timer measurement begins when you switch on the 
humidifying function.  
 

As indicated, the water level monitor behaves as following: 

 

Air Flow speed

 

Run time till Water level Status 

 

 

 

High 

10 Hours  

Middle 

12 Hours  

Low 

14 Hours 

Whisper mode/Sleep function  16 Hours 

  

The water level monitor is automatically reset when switching off the humidifier function. 

  
  

 

 

 

Remove the front cover 

Fill the water tank and push it  

back in  

Содержание AirJet 2000

Страница 1: ...Air Purifier AirJet 2000 ...

Страница 2: ...t SAFETY INSTRUCTIONS 3 PRODUCT DESCRIPTION 5 INSTALLATION 7 FILTER CHANGING 10 FILLING THE WATER TANK 12 SERVICING AND CLEANING OF THE WATER TANKS AND ITS COMPONENTS 13 TROUBLE SHOOTING 13 TECHNICAL DETAILS 13 ...

Страница 3: ...pliance in water or other fluids There is a danger of electric shock Keep a clear distance from wet areas and do not operate this device in moist environments or rooms This appliance may only be installed or operated by a competent person who is physically and mentally capable of correctly understanding this operation manual or has been sufficiently trained by a responsible person in its use Do no...

Страница 4: ...ce is not suitable for filtering oil or fatty air such as in kitchens Do not use this product in bathrooms or other damp environments Do not use this air purifier in rooms where the appliance can come into contact with flammable or light flammable gasses Before using this appliance ensure that all plastic packaging has been removed and the appliance is ready for use The filter must be removed from...

Страница 5: ...5 Product Description Illustration 1 Opening for Display Control Panel Particle Sensor Air intake Air Quality Indicator Roller wheels Illustration 2 Front Cover Water Tank Filter Air Exhaust ...

Страница 6: ...ng the fan speed D Auto Activate Deactivate the Automatic control E Anion Activate Deactivate the Ionisatiors F Humidifier Activate Deactivate the Humidifying Function G Power ON OFF Switch H Sleep Activate Deactivate the Sleep Mode I Child Lock Activate Deactivate the Child Safety Lock J Filter reset Reset the Filter replacement indicator L Light Sensor ...

Страница 7: ...ality indicator shows the actual fine particle pollution level using several coloured LEDs in the air outlet PM 2 5 Pollution Indicated Colour 100 red high pollution 50 100 yellow middle pollution 50 blue low pollution Operation ON OFF Switch of the air purifier By pressing the Power button the air purifier is switch ON or OFF In standby mode it glows red during operation it glows white Regulating...

Страница 8: ... Air Purifier independently switches back into automatic mode Control of the Ionisators By activating the Anion Button the Ionisator can be turned on or off If the Ionisator is activated the corresponding key lights up in white Setting the Timer function By repeatedly pressing the Timer Key whilst the appliance is operating you can set the run time Thereby there are run time choice available of 2 ...

Страница 9: ... turning on the air purifier s automatic function the air purifier independently controls the selected air quality to the optimum level PM 2 5 Pollution Air Purifier Level 100 High 50 100 Middle 50 Low Setting the Humidifying Function By confirming the key Humidifier the humidifying function is turned ON respectively OFF If the function is activated the button illuminates and a shutter is opened i...

Страница 10: ...e the cleaning action of the air purifier To change the filter please proceed as follows Always switch off the air purifier and remove the plug from the socket before you start with changing the filter Refer to the illustrations and descriptions below for changing the filters Remove the front Cover Replace the filter Re mount the front cover After changing the filter restart the appliance into ope...

Страница 11: ...lter Reservoir of the water tank To change the filter please proceed as follows Always switch off the air purifier and remove the plug from the socket before you start with changing the filter Refer to the illustrations and descriptions below for changing the filters After changing the filter restart the appliance into operation Press and hold the Filter reset key for approx 5 seconds to reset the...

Страница 12: ... is fitted with timer based water level monitor which advises you when to review the water level The timer measurement begins when you switch on the humidifying function As indicated the water level monitor behaves as following Air Flow speed Run time till Water level Status High 10 Hours Middle 12 Hours Low 14 Hours Whisper mode Sleep function 16 Hours The water level monitor is automatically res...

Страница 13: ...e humidifier filter After you have replaced the filters fill the water tank with clean cold water and insert back into the appliance Trouble Shooting Error Solution Appliance will not start Is the front cover correctly inserted Is the life span of the filters reached Appliance is very loud Are the filters correctly inserted Is the packaging of the filters removed Only low level of air purifying Ar...

Страница 14: ...8612 www bwishop de This product must not be disposed of in normal household rubbish This air purifier must be disposed of in a recycling depot for electronic and electrical appliances More information concerning acceptable recycling depots is available from your local council or city administration ...

Отзывы: