background image

II. Network Inclusion/ Exclusion 

The sensor must be added to the Zwave network prior to use. To include the sensor in a 
network both the sensor and the Network controller or HUB must be in inclusion mode 
at the same time.  

Add :

 start by placing the controller in inclusion mode. Activate the inclusion mode at 

the sensor pressing the tamper switch 3 times, then the door sensor will stay in 
enrollment state. 

Wait about 15-30 seconds while the sensor and controller finished the inclusion 
process. 

Remove:

 enter the Exclusion Mode on the controller, and press the tamper switch 3 

times, then the door sensor will be removed after 15-30 seconds. 

III. Restore Factory Settings 

 

Press the tamper switch for 6 times to restore factory settings. 

[email protected]

Содержание X32_ZWAVE

Страница 1: ...mune Special Fresnel lens with patented technology built in far infrared wave with above 95 transmittance rate Adopt original imported Heimann sensor from Germany with high sensitivity low false alarm Real anti visible light technology no false alarm under 6500LUX strong light interference With sealed induction cavity design prevent false alarm caused by thermal current interference Configurable d...

Страница 2: ...Detection Area info besense iot com ...

Страница 3: ... Activate the inclusion mode at the sensor pressing the tamper switch 3 times then the door sensor will stay in enrollment state Wait about 15 30 seconds while the sensor and controller finished the inclusion process Remove enter the Exclusion Mode on the controller and press the tamper switch 3 times then the door sensor will be removed after 15 30 seconds III Restore Factory Settings Press the t...

Страница 4: ...when it checks three pulses The pulse count is higher and the sensitivity is lower but can reduce false alarm Test Mode High Battery consumption Alarm will be triggered each 5s Power save Mode Recommended Alarm will be triggered again with above 3min interval from its first alarm After triggered it will send alarm elimination signal to the relevant device in at least 3 minutes Code Mode without an...

Страница 5: ...info besense iot com ...

Страница 6: ...the handler Customized to avoid false alarms Generate Tamper alerts Battery indicator Colors and Background improved How to ADD a device Handler for the BeSense Motion Sensor 1 Log in here with the same username and password you use for your SmartThings app https graph api smartthings com login auth info besense iot com ...

Страница 7: ...ate new device handler and choose From code from the top tab menu You ll be presented with a blank area where you can copy the code from this link and paste it in it s always best to use the raw version of the code https besense iot smartthings besense_handler txt info besense iot com ...

Страница 8: ...4 Next scroll to the bottom and click Create Now click Save then click Publish for me info besense iot com ...

Страница 9: ... New Device in your app Press and release the tamper switch three times on the sensor quickly Remember to keep the device within 3 feet away from your hub during inclusion the device should be automatically discovered as the BeSense Motion sensor Then leave the sensor by the hub for a few hours so it can fully configure And that should be it I hope this was helpful in simplifying the process behin...

Страница 10: ...h for 0 5s Sensor Binary Report Value 0x00 Type 0x08 Notification Report Notification Type 0x07 Event 0x00 Association Group2 If there is any device under Association Group2 the door sensor will send BASIC SET command to control those devices when the door sensor is triggered For example when the door sensor is triggered it sends adjustable parameter BASIC SET command to a lamp under Group2 you ca...

Страница 11: ... Basic Set command after t seconds c PIR Sensor Alarm Elimination Time Configuration Min set time is 5s If the configuration is 1 that means it will eliminate alarm after 1 5s 5 seconds if t will eliminate alarm after t 10s Z Wave Supportive Commands Generic Deice Type GENERIC_TYPE_SENSOR_BINARY Specific Device Type SPECIFIC_TYPE_ROUTING_SENSOR_BINARY Support Command Class COMMAND_CLASS_ZWAVEPLUS_...

Страница 12: ...SS_NOTIFICATION_V4 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY Commands to Control Other Devices COMMAND_CLASS_BASIC info besense iot com ...

Отзывы: