BESEN INTERNATIONAL GROUP CO., LTD.
BESEN-GROUP.COM, leading the EV Charging to a better way
Page 7
The function area includes the emergency stop button, indicated lights and socket (or
outlet). The interior part includes the leakage current circuit breaker (both over-load and
short circuit protection), lightning protection module, charging control module and
charging control contactor, etc.
1.
Emergency Stop: To shut down charging when it is abnormal.
2.
Indicated Lights: To indicate the charging situation.
3.
Socket (or outlet): In type C connection, it is for fixing the charging plug; in
type A connection is for connecting the charging plug.
4.
Leakage current circuit breaker: Automatically detect the leakage current. When it is or
over 30mA, the charging station will cut the power supply automatically to protect
personal safety; when over-load or short circuit fault, it is for device protection.
5.
Lighting Protection Module: To limit the overvoltage and prevent the damage.
6.
Charging Control Module: To complete the charging connection control with EVs and
collect data, etc.
7.
Charging Control Contactor: To control the output of power supply.
2.5 Features
1.
Easy to operate, when plug-in, it starts (if with keys, start by key firstly).
2.
The protection function includes the leakage current, over-current, emergency stop
and lightning, etc.
2.6 Product Positioning
Household.
2.7 Technical Parameters
For differences of connection mode and installation mainly reflect in structure and
slight differences on electrical parameters. So in the following, it lists the data sheet of
the AC charging station mainly on power supply mode (single-phase and
three-phase).
Table 2-1 Technical Parameters
Model No.
BS-B10
=
Electric Parameters
Rated Voltage
220VAC±10% (Single-phase)
380VAC±10% (Three-phase)
Rated Frequency
50Hz±1%