ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the
appliance for the purpose of turning on or shutting off gas to the appliance
WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation
Requirements
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the appropriate national and local standards.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the appropriate national and local standards.
INSTALLATION MANUAL
ANTI-TIP STABILlTY DEVICE INSTALLATION INSTRUCTIONS
1. The anti-tip bracket have to be installed to the rear wall as shown. The height for the bracket location from
the floor has to be determined after the range legs have been adjusted to the proper installation height - as
shown in the installation instructions – and after the range has been leveled.
2. Measure from the floor to the bottom of the anti-tip bracket location on the back of the range.
3. Position the two anti-tip brackets on the wall at the measured dimension plus 1/8" (0.32 cm). The brackets
have to be placed at 2”5/16 (6,0 cm) from the side of the range. The distance between the two bracket is
19”1/4 (48,8 cm) clearance. Secure with suitable inserts.
4. Slide the range against the wall until the brackets are fully inserted into the holes on the backside of the
range..