background image

 

8

Regulation of burners 

Regulation of the "MINIMUM" on the burners 

To regulate the minimum on the burners carry out the following procedure indicated below: 
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ). 
2) Remove the knob ( Fig. 7) of the tap which is set for standard pressure. The knob is found on the bar of 
the tap itself. 
3) Beside the tap bar on the work top, insert a small slotted screwdriver into the hole on the vale rod (Fig. 7) 
and turn the choke screw to the right or left until the flame of the burner is regulated in the most suitable way 
to MINIMUM. 
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the 
MINIMUM position.  

ATTENTION: The regulation described above can be carried out only with burners using natural gas, 
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.   

 

 

 

  

 

               

Adaptation of the pressure regulator for use with different type of gas 

The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with 
Natural Gas at a nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is 
pre-arranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging 
labels affixed on the appliance, package and Instruction booklet. 

To convert the regulator for use with the other gas different from which one it is pre-arranged it is enough 
perform the following operations: 

1) Unscrew by hand the upper metal stopper of the regulator (Fig. 5A). 

2) Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper, afterward 
screw it again in opposite way under the metal stopper (for gas reference see the written “LP” and “NAT” with 
relative indicating arrows on the white piece). 

3) Screw again by hand the metal stopper in the original position on the regulator. 

Operating in this way the gas regulator is converted for use with the other gas/pressure. 

 
 
Service & maintenance instructions 

Service and maintenance only to be carried out by an authorised person 

To replace parts such as burners, valves and electric components, the hotplate must be removed from the 
bench top by releasing the attachment hooks, loosening the attachment screws of each burner, unscrewing 
the hotplate attachments nuts which are visible at the bottom of the surface, removing the hotplate top and 
finally replacing the defective parts. 

Note:

 if the valves must be replaced, first disassemble the ignitions switches wires. 

It is recommended to replace the valve gaskets each time the valve is replaced, thus ensuring a perfect seal 
between the body and the gas train. 

WARNING: Disconnect power before servicing unit. 

For the location of the wall receptable for the connection of the three-pin earthed plug of the 
appliance, see indications given in Fig. 1- 2  

WARNING: After first installation of the appliance or after any service intervention concerning main 
gas parts of the appliance, make the leak test using water with soap on the gas connections in order 
to verify the correct installation. Do not use fire for gas leak testing. 

 
 

Содержание service and

Страница 1: ...Installation Service and User Instructions FREESTANDING GAS RANGES BERTAZZONI DIMENSIONS 24 605 mm W x 25 1 8 640 mm D x36 911 mm H MODEL X244GGVX MLS0GTU4X 2 or 5 A 310287 ...

Страница 2: ...SA C22 1 Canadian Electrical Codes Part 1 and or local codes Installation of any gas fired equipment should be made by a licensed plumber A manual gas shut off valve must be installed in the gas supply line ahead of the oven in the gas flow for safety and ease of service IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE OBSERVE ALL GOVERNING ...

Страница 3: ...ssure regulator has female pipe thread The appropriate fitting must be determined based on the size of your gas supply line the flexible metal connector and the shutoff valve The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 The appliance must be isolated from the gas supply pipi...

Страница 4: ...rds INSTALLATION MANUAL ANTI TIP STABILlTY DEVICE INSTALLATION INSTRUCTIONS 1 The anti tip bracket have to be installed to the rear wall as shown The height for the bracket location from the floor has to be determined after the range legs have been adjusted to the proper installation height as shown in the installation instructions and after the range has been leveled 2 Measure from the floor to t...

Страница 5: ... hardware It is recommended to use a pallet or lift jack instead of tilting the unit BACKGUARD INSTALLATION INSTRUCTION It s always compulsory to installa the riser even for an island installation 1 Remove n 2 screws fixing worktop as shown in fig 1 2 Place front part of the backguard and attach it from bottom side with the two removed screws point 2 as shown in fig 2 3 Fix the front part of the b...

Страница 6: ...o increase the clearance between front edge of the worktop and the burners for your safety it is recomended to install the worktop frontguard supplied with the appliance For installation instructions follow the instructions indicated in the following figures ...

Страница 7: ... installed directly adjacent to sidewalls tall cabinets tall appliances or other vertical surfaces above 36 91 4 cm high There must be a minimum of 6 15 2 cm side clearance 3 Within the side clearance to combustible vertical surfaces above 36 91 5 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this side clearance must be 18 45 7 cm above countertop level and countert...

Страница 8: ...a SJT power cord In case of replacement the cable shall be replaced with one of the same type size and length WARNING Cooling fan failure In case of a cooling fan failure the frontal red indicator Fan Failure will light up If this happens please turn off the appliance immediately call the nearest after sale assistance service center and do not use the appliance until the cooling fan system of the ...

Страница 9: ...r has two female threads NPT it shall be installed properly in order to be accessible when appliance is installed in final position b Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company Please provide the service person with this manual before work is started on the range Gas conversions are the responsibility of the dealer or end user c ...

Страница 10: ... operations Flames should be blue in all settings If service is required contact your dealer for the name of their authorized service agency Gas conversions and initial installation are not the responsibility of the manufacturer The installer should carry out the following performance checks Refer to instructions below 1 Check surface burner ignition 2 Check air shutter adjustment only for oven an...

Страница 11: ...t To convert the regulator for use with other types of gas follow these instructions 1 Unscrew by hand the upper metal stopper of the regulator 2 Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper afterward screw it again in opposite way under the metal stopper for gas reference see the written LP and NAT with relative indicating arrows on the white piece 3 Scr...

Страница 12: ...ted in Table below Models X244GGVX MLS0GTU4X 2 or 5 A Adapting to different types of gas Burner Position Injector Gas Pressure Max Rate Min Rate By pass diam mm Type i w c BTU h W BTU h W diam mm Auxiliary Rear L 0 90 NG 4 3400 996 900 264 Regulated 0 54 LP Propane 11 3400 996 900 264 0 29 Semi Rapid Front R 1 18 NG 4 6100 1787 1500 439 Regulated 0 70 LP Propane 11 6100 1787 1500 439 0 36 Rapid Re...

Страница 13: ...quickly from the MINIMUM to the MAXIMUM position WARNING The above mentioned adjustment should be made only for natural gas while for operation with liquid gas the screw must be locked at the end in a clockwise direction The broiler burner always operates at maximum and therefore no minimum adjustment is required SERVICE MAINTENANCE INSTRUCTIONS Service and maintenance only to be carried out by an...

Страница 14: ...ee from combustible materials gasoline and other flammable vapors and liquid Do not store dangerous or flammable material in the cabinet areas above appliance store them in a safe place in order to avoid potential hazards For safe use of appliance do not use it for space heating Do not use aerosol sprays in the vicinity of this appliance while it is in operation Do not use oven doors as support or...

Страница 15: ...he knob down to activate the spark ignition Once ignited keep pressing the knob for about 10 seconds to allow the flame to heat the thermocouple If the burner does not remain alight after releasing the knob repeat the above procedure Note It is recommended not to try to ignite the burner if the relative flame cap is not in the correct position Note Dual burner is composed by two burner inside and ...

Страница 16: ...RNING If the power is cut off the burners can be lit with matches The burners equipped with a safety thermocouple can only be lit when the knob is in the MAXIMUM position large flame etching USING THE GAS OVEN All the gas oven cookers are equipped with a thermostat and safety device to adjust the cooking temperature The oven temperature is set by turning the knob counterclockwise to match the indi...

Страница 17: ...n be used to insert shelves or the tray To keep the oven as clean as possible it is recommended to cook meat on the tray or on the shelf that has been inserted inside the tray The table below lists the general cooking times and the position of the tray for different types of foods Personal experience will help to determine any variations in the values reported in the table In any case it is recomm...

Страница 18: ...oven knob but turning it clockwise instead of counterclockwise see the gas oven use instructions matching the symbol with the indicator The broiler burner always operates at maximum and therefore there is no minimum position In addition it is equipped with a safety device to prevent the flame from going out The gas broiler can also be ignited in different ways Manual lighting Just completely open ...

Страница 19: ... it but immediately request the assistance of the technical service personnel Cleaning the enamelled parts Enamelled parts should be cleaned frequently with soapy water Never use abrasive powder Do not leave acidi or alkaline substances on the enamelled parts such as vinegar lemon juice salt tomato sauce etc and do not wash the enamelled parts while they are still hot Cleaning the stainless steel ...

Страница 20: ...NER 2 425 415054 SPARK PLUG 350MM 3 427 415074 SPARK PLUG FOR OVEN 1 429 415072 SPARK PLUG FOR GRILL 1 430 415064 ACCUMULATOR 4U 2 441 404217 GRID FOR OVEN 1 442 404216 SHELF OVEN 2 443 404497 GRID FOR TRAY 1 444 202407 FLASK HINGE 2 446 405082 OVEN DOOR HINGE 2 447 404218 GRID FOR OVEN 1 473 408069 SIMMER PLATE 1 478 410631 FLAP DOOR 1 544 504203 OVEN BURNER SPARK PLUG THERMOC 1 546 505059 SUPPOR...

Страница 21: ...2 210620 CONTROL PANEL 1 1603 309119 BRIDLE FOR FIXING GAS VALVES THERMOSTAT 1 1608 501778 ALL TUBE FOR OVEN BURNER 1 1609 505056 SUPPORT FOR OVEN BURNER NOZZLE 1 1614 201182 BACK PANEL 1 1615 202477 CONTROL SUPPORT 1 1617 608045 SMALL BLUE BUD 1 1622 608025 SMALL RED BUD 1 1624 200371 WORK TABLE 1 1627 501777 GAS COLLECTOR 1 1628 501784 TUBE FOR RIGHT FRONT BURNER 1 1631 501785 TUBE FOR RIGHT BAC...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ... liquid in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas suppliers call the fire department Installation and service must be performed by a ...

Страница 30: ...be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system any pressure testing of that system at test pressure in excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its indi...

Страница 31: ... fig 1 fig 2 Requirements 1 Overhead clearances Minimum values The minimum overhead clearances shall be in accordance with the minimum values indicated in the table n 1 and are shown and in the fig 1 2 Range hoods and exhaust fans shall be installed in accordance with the manufacturer s instructions However in no case shall the clearance between the top of the highest burner of the cooking applian...

Страница 32: ... accidentally into the underlying storage space the appliance is equipped with a special gasket To apply this gasket carefully follow the instructions in Fig 3 Lay out the protective sealing strips along the edges of the opening in the bench top and carefully overlap the strip end See Fig 3 insert the hotplate into the bench top opening With a screwdriver assemble the brackets A to the hotplate bo...

Страница 33: ...ll indicate a leak Tighten the fitting and re check for leaks If it is not possible to correct the leak replace fitting Under no circumstances use matches or flame for checking leaks It is essential that the gasket and the pressure test point stopper are properly installed to avoid gas leakage Fig 5A 7 To checking inlet pressure at the appliance operate as follow a Disconnect electric power before...

Страница 34: ...NING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptable Do not cut or remove the grounding prong from this plug Wiring diagrams Instructions for assembly of load bearing bottom protection After the installation of the hob 5 proceed with the assembl...

Страница 35: ...escribed in fig 5A CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS To change the nozzles of the burners use the following procedure Lift up the burners and unscrew the nozzles Fig 6 using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE A shown below fig 6 fig 7 TABLE A Adapting to different types of ga...

Страница 36: ...erform the following operations 1 Unscrew by hand the upper metal stopper of the regulator Fig 5A 2 Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper afterward screw it again in opposite way under the metal stopper for gas reference see the written LP and NAT with relative indicating arrows on the white piece 3 Screw again by hand the metal stopper in the orig...

Страница 37: ...n the power is cut off or in the event of prolonged power failure Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star large flame and place a lit match up to the burner Automatic electric ignition Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star large flame and then press ...

Страница 38: ...brasive cleaners Before cleaning the appliance it should be disconnected from the power supply Cleaning the work surface periodically clean the burner heads the cast iron pan supports and the burner caps using warm water Any spillage must always be removed as soon as possible using a rag If it become difficult to open or close a valve do not force it but immediately request the assistance of the t...

Страница 39: ...e service Refer to warranty certificate for warranty condiftions Dealer Importer Name address phone MANUFACTURER BERTAZZONI SPA VIA PALAZZINA 8 42016 GUASTALLA REGGIO E ITALY Tel 0522 226411 telefax 0522 226440 http www bertazzoni italia com SERVICE CENTERS Name Phone ...

Страница 40: ...bles à proximité de celui ci ou de n importe quel autre appareil CE QU ON DOIT FAIRE EN CAS D ODEUR DE GAZ N essayez d allumer aucun appareil Ne touchez aucun interrupteur électrique N utilisez aucun téléphone dans votre établissement Appelez immédiatement votre fournisseur de gaz par le téléphone d un voisin Suivez les instructions du fournisseur de gaz Si vous ne pouvez pas atteindre vos fournis...

Страница 41: ...hement de cette table de cuisson au conduit d amenée des gaz Ne pliez pas ou n endommagez pas le connecteur flexible en déplaçant la table de cuisson Le régulateur de pression a un filetage au pas du gaz femelle de Vous devrez déterminer le raccordement demandé selon la dimension du conduit d amenée des gaz du connecteur en métal flexible et du robinet d arrêt L appareil lorsqu il est installé doi...

Страница 42: ...ter le gaz à l appareil AVERSTISSEMENT Ne pas utiliser de pulvérisateurs d aérosol à proximité de cet appareil lorsqu il est en fonction Insertion de la table de cuisson Après avoir enlevé les différentes parties libres à l intérieur et à l extérieur de l emballage assurez vous que la table de cuisson ne soit pas endommagée et qu elle soit appropriée pour l utilisation du gaz spécifique L étiquett...

Страница 43: ...pareil qui contiennent les boutons de contrôle Table n 1 Distances Min pouches mm Distances Min pouches mm L1 18 7 8 480 L10 22 1 2 570 L2 1 9 16 40 L11 32 813 L3 3 3 8 86 W 23 1 4 590 L4 18 457 D 19 2 3 500 L5 24 610 B1 1 3 8 35 L6 13 330 B2 3 1 2 90 L7 23 1 4 590 B3 3 76 L8 3 4 20 B4 3 1 2 90 L9 3 15 16 100 R 5 1 8 135 Notes B1 est la distance min entre le bord frontal de l appareil et le bord f...

Страница 44: ...el la ligne de distribution de gaz est connectée au régulateur qui est fourni séparément Le branchement d entrée a un filetage mâle de 1 2 B S P filetage Whitworth pour tuyaux IL EST ESSENTIEL QUE LE COUDE SUR L APPAREIL SOIT FERMEMENT RETENU AVEC UNE CLE LORSQU ON BRANCHE L ALIMENTATION NE PAS SERRER La pression réglée pour GN est de 4 colonne d eau Voir Fig 5A 6 Pour la position d entrée du gaz ...

Страница 45: ...tête d injecteur à filetage mâle 9 Parfois les brûleurs ne s enflamment pas immédiatement et semblent souffler légèrement quand ils s allument Cela est dû à l air dans les canalisations de gaz qui disparaîtra dans peu de secondes 10 Si après les instructions données une performance satisfaisante n a pas été obtenue contactez l autorité locale du gaz pour demander conseil et assistance Branchement ...

Страница 46: ... où se trouve l appareil en chaque cas il doit etre eventuellement installé conformement aux normes nationals en vigueur NOTE Le fonctionnement d une hotte d aspiration peut avoir influence sur les autres appareils a gaz qui functionnent dans le meme local en chaque cas elle doit etre eventuellement installée conformement aux normes nationals en vigueur Conversion à différents types de gaz Avant d...

Страница 47: ...la barre du robinet même 3 Près de la barre du robinet sur le top de travail insérez un petit tournevis a encoches dans la tige de soupape Fig 7 et tournez la vis du réducteur de pression à droite ou à gauche jusqu à ce que la flamme du brûleur soit réglée de la manière la plus appropriée au MINIMUM 4 S assurer que la flamme ne sorte pas en changeant rapidement la position du MAXIMUM en position d...

Страница 48: ...s câbles des interrupteurs d allumage Il est recommandé de remplacer les joints de la valve chaque fois que la valve est remplacée assurant de cette façon l étanchéité parfaite entre le corps et le train de gaz ATTENTION Débranchez l alimentation avant l entretien de l unité Pour le positionnement de la prise au mur pour le branchement de la bonde de mise à terre à trois pôles de l appareil voir l...

Страница 49: ...eur ne reste pas allumé après avoir relâché le bouton répétez le procédé ci dessus Avertissement Il est recommandé de ne pas essayer d allumer le brûleur si le chapeau de la flamme relative n est pas en position correcte Suggestions pour une utilisation correcte des brûleurs ATTENTION Pendant l utilisation de chaque brûleur réglez la dimension de la flamme du brûleur correctement de façon à ce qu ...

Страница 50: ...ce du personnel du service technique Nettoyage des parties émaillées Les parties émaillées devront être nettoyées fréquemment avec de l eau savonneuse N utilisez jamais de poudres abrasives Ne laissez pas de substances acides ou alcalines sur les parties émaillées comme par exemple du vinaigre jus de citron sel sauce de tomate etc et ne lavez pas les parties émaillées lorsqu elles sont encore chau...

Страница 51: ...0 504128 SMALL FLAME SPREADER TETE BRULEUR PETIT 1 671 504129 MEDIUM FLAME SPREADER TETE BRULEUR MOYEN 2 676 504108 ULTRA RAPID FLAME SPREADER TETE BRULEUR COURONNE 1 702 408058 ADAPTER FOR WOK BURNER PAN SUPPORT ADAPTATEUR COURONNE 1 723 411070 GASKET GARNTURE 4 760 510507 SMALL BURNER COUPE BRULEUR PETIT 1 761 510508 SEMI RAPID BURNER COUPE BRULEUR MOYEN 2 769 510506 ULTRA RAPID BURNER COUPE BRU...

Страница 52: ......