background image

 

9

 

Fig. 3A 

 

 

 

 

 

 

Fig. 3B 

 

 
 

   

   

  

Fig.4   

 

                  Fig.5A 

 

 

           Fig.5B 

 

 

 

Fig.6    

 

 

 

                         Fig.7   

Содержание PM36500X

Страница 1: ...INSTRUCTIONS FOR THE INSTALLATION MAINTENANCE AND USE OF FIXED HOBS WITH GAS OR MIXED SUPPLY DIMENSIONS 890 mm W x 520 mm D Models PM36500X Type A Models PM365S0X Type B ...

Страница 2: ...responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance The manufacturer reserves the right to make changes to its products when considered necessary and useful without affecting the essential safety and operating characteristics This appliance has been designed for non professional domestic use only INFORMATION FOR THE INSTALLER The i...

Страница 3: ...etween the front edge of the appliance and the front edge of the cabinet B2 and B4 are the min clearance between the left right side edge of the appliance and the side wall if present B3 is the min clearance between the back edge of the appliance and the back wall Attaching the hotplate To prevent liquids from leaking accidentally into the underlying storage space the appliance is equipped with a ...

Страница 4: ... a well ventilated place ATTENTION Remember that the gas inlet connection for the appliance is threaded 1 2 gas cylindrical male in accordance with the norms UNI ISO 228 1 Fig 6 7 CONNECTION OF THE APPLIANCE TO THE ELECTRICITY SUPPLY Connection to the electricity supply must be carried out according to the norms and indications of the law in force Before carrying out the connection check that The ...

Страница 5: ...electric mains cable the installer must have the earth conductor about 2 cm longer than the phase conductors and must also take heed of the warnings regarding electric connection Room ventilation Location and venting ATTENTION An exhaust fan may be used with the appliance in each case it shall be installed in conformity with the national standards in force ATTENTION Exhaust hood operation may affe...

Страница 6: ...ch are visible at the bottom of the surface removing the hotplate top and finally replacing the defective parts Note if the valves must be replaced first disassemble the ignitions switches wires It is recommended to replace the valve gaskets each time the valve is replaced thus ensuring a perfect seal between the body and the gas train WARNING Disconnect power before servicing unit For the locatio...

Страница 7: ...it with matches The burners equipped with a safety thermocouple can only be lit when the knob is in the MAXIMUM position large flame etching Note The use of a gas cooking appliance produces heat and humidity in the room where it is installed Therefore proper ventilation in the room is needed and natural ventilation openings must remain unobstructed and activating the mechanical exhaust fan range h...

Страница 8: ...8 Fig 1 Fig 2 Fig 3 ...

Страница 9: ...9 Fig 3A Fig 3B Fig 4 Fig 5A Fig 5B Fig 6 Fig 7 ...

Страница 10: ...10 Fig 8 Fig 9 Fig 10 ...

Страница 11: ...11 Fig 11 Fig 12 Fig 13 Fig 14 ...

Страница 12: ...12 3100071 ...

Отзывы: