The  installer  should  note  that  the  appliance
that  side  walls  should  be  no  higher  than  the
hot  plate  itself.  Furthermore,  the  rear  wall,  the
surfaces  surrounding  and  adjacent  to  the
appliance  must  be  able  to  withstand  an
temperature of 90 °C.
The adhesive used to stick the plastic laminate
to  the  cabinet  must  be  able  to  withstand  a
temperature  of  not  less  than  150  °C  otherwise
the laminate could come unstuck.
The appliance must be installed in compliance
with the provisions in force.
This  appliance  is  not  connected  to  a  device
able  to  dispose  of  the  combustion  fumes.  It
must  therefore  be  connected  in  compliance
with  the  above  mentioned  installation
standards.  Particular  care  should  be  paid  to
the  following  provisions  governing  ventilation
and aeration.

5) ROOM VENTILATION

It is essential to ensure that the room in which the
appliance  is  installed  is  permanently  ventilated  in
order  to  allow  the  appliance  itself  to  operate
correctly.  the  necessary  amount  of  air  is  that
required  for  regular  gas  combustion  and
ventilation  of  the  relative  room,  the  volume  of
which  must  not  be  less  than  20  m

3

. Air  must

naturally  flow  through  permanent  openings  in  the
walls  of  the  room  in  question.  These  openings
must  vent  the  fumes  outdoors  and  their  section
must be at least 100 cm

2

(see fig. 3). Construction

of  the  openings  must  ensure  that  the  openings
themselves  may  never  be  blocked.  Indirect
ventilation  by  air  drawn  from  an  adjacent  room  is
also  permitted,  in  strict  compliance  with  the
provisions in force.

CAUTION: if the burners of the cooking top are
without  safety  thermocouple,  the  ventilation
outlet must have a minimum 200 cm² section.

6) LOCATION AND AERATION

Gas  cooking  appliances  must  always  dispose  of
their  combustion  fumes  through  hoods.  These
must  be  connected  to  flues,  chimneys  or  straight
outside.  If  it  is  not  possible  to  install  a  hood,  an
electric  fan  can  be  installed  on  a  window  or  on  a
wall  facing  outside  (see  fig.  4).  This  must  be
activated  at  the  same  time  as  the  appliance  (see
fig.  5),  so  long  as  the  specifications  in  the
provisions in force are strictly complied with. 

7) GAS CONNECTION

Before  connecting  the  appliance,  check  that
the  values  on  the  data  label  affixed  to  the
underside of the hot plate correspond to those
of the gas and electricity mains in the home.
A label on the appliance indicates the 
regulating conditions: type of gas and working

pressure.  Gas  connection  must  comply  with
the  pertinent  standards  and  provisions  in
force. 

When  gas  is  supplied  through  ducts, 

the

appliance  must  be  connected  to  the  gas  supply

system:

● with  a  rigid  steel  pipe.  The  joints  of  this  pipe

must  consist  of  threaded  fittings  conforming  to

the standards. 

● With  copper  pipe.  The  joints  of  this  pipe  must

consist of unions with mechanical seals.

● With  seamless  flexible  stainless  steel  pipe. The

length of this pipe must be 2 meters at most and

the seals must comply with the standards.

When  the  gas  is  supplied  by  a  bottle, 

the

appliance must be fuelled by a pressure governor

conforming to the provisions in force and must be

connected:

● with  a  copper  pipe. The  joints  of  this  pipe  must

consist of unions with mechanical seals.

● With  seamless  flexible  stainless  steel  pipe. The

length of this pipe must be 2 meters at most and

the  seals  must  comply  with  the  standards.  It  is

advisable  to  apply  the  special  adapter  to  the

flexible  pipe.  This  is  easily  available  from  the

shops  and  facilitates  connection  with  the  hose

nipple of the pressure governor on the bottle.

● With  rubber  hose  pipe  in  compliance  with

standards. The diameter of this hose pipe must

be  8  mm  and  its  length  must  be  no  less  than

400 mm and no more than 1500 mm. It must be

firmly  fixed  to  the  hose  nipple  by  means  of  the

safety clamp specified by standards.

WARNINGS:
remember  that  the  gas  inlet  union  on  the
appliance  is  a  1/2"  gas  parallel  male  type  in
compliance with EN 10226 standards.
Installation  of  stainless  steel  pipe  and  rubber
hose  pipe  must  ensure  that  it  is  never  able  to
touch  mobile  parts  of  the  built-in  cabinet  (eg.
drawers).  Furthermore,  it  must  not  pass
through  compartments  that  could  be  used  for
storage purposes.
When using a rubber hose pipe, it is essential
to comply with the following instructions:
- no  part  of  the  pipe  must  be  able  to  touch

parts the temperature of which exceeds 90 °C.

- The  pipe  must  not  be  pulled  or  twisted,

throttled or tughtly bent.

- It  must  not  come  into  contact  with  sharp

edges or corners.

-  It  must  be  easy  to  inspect  the  entire  pipe

length in order to check its state of wear.

-  The  pipe  must  be  replaced  within  the  date

stamped on the pipe itself.

-  The  appliance  complies  with  the  provisions

of the following CEE Directives:

CEE 2009/142 + 93/68 regarding gas safety.

Содержание P7C01G9XT

Страница 1: ... of the instruction manual and on the appliance itself The manufacturer shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance Model P7C01CONXF The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors the designs in the figures are purely indicative The Manufac...

Страница 2: ...pport 4 Burner n 1 control knob 5 Burner n 2 control knob Attention this appliance has been manufactured for domestic use only and it employment by private person DESCRIPTION OF HOBS TYPE PCZ 90 A P7C01G9XT P9C01G9X7 A B P9C01G9X7 860 450 P7C01G9X7 780 450 DIMENSIONS HOBS in mm ...

Страница 3: ...g very flexible use thanks to the possibility to light either the inner flame only or the whole burner inner and outer flame at the same time LIGHTING AND USING THE DUAL BURNER Stand the pan on the burner before lighting Despite being controlled by a single knob the DUAL burner can be used in two different ways A Using the complete burner starting from the off position You must first press the kno...

Страница 4: ...d should be immediately removed from this before it is opened If the appliance has a glass lid this could shatter when the hot plate becomes hot Always switch off all the burners before closing the lid The machine must not be used by people including children with impaired mental or physical capacities or without experience of using electrical devices unless supervised or instructed by an expert a...

Страница 5: ...ty with current law on the protection of health and the prevention of environmental pollution by making its dangerous parts harmless especially for children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage resulting from improper incorrect or unreasonable use Durin...

Страница 6: ... clean rag Burnt or soiling may be removed with a special razor scraper fig 6 be aware that the razor can cause wounds Marks of liquid overflowed from the pot can be removed using vinegar or lemon Pay attention to not let fall sugar or element with sugar In this case turn the switch off and clean the surface with hot water and the razor blade scraper After a period of time may appear metal reflex ...

Страница 7: ...ance and contact qualified personnel Never leave the packaging materials cardboard bags polystyrene foam nails etc within children s reach since they could become potential sources of danger The measurements of the opening made in the top of the modular cabinet and into which the hot plate will be installed are indicated in either fig 7 Always comply with the measurements given for the hole into w...

Страница 8: ...perfectly matches the outer perimetral edge of the crystal The ends of the strips must fit together without overlapping Evenly and securely fix the seal to the crystal pressing it in place with the fingers Insert the hooks into their relative housings and fix them to the body using screws G fig 10 Fix the appliance in the hole made on the furniture and lock it with the proper screws F of the fixin...

Страница 9: ... hot plate correspond to those of the gas and electricity mains in the home A label on the appliance indicates the regulating conditions type of gas and working pressure Gas connection must comply with the pertinent standards and provisions in force When gas is supplied through ducts the appliance must be connected to the gas supply system with a rigid steel pipe The joints of this pipe must consi...

Страница 10: ...ricity main install an omnipolar circuit breaker between the appliance and the electricity main This circuit breaker should be sized in compliance with current installation regulations Remember that the earth wire must not be interrupted by the circuit breaker For optimum safety the electrical connection may also be protected by a high sensitivity differential circuit breaker You are strongly advi...

Страница 11: ... beside the tap fig 12 or inside the shaft In any case to access to regulation it can be done trought the insertion of a small screwdriver D beside the tap fig 12 or in the hole C inside the shaft of the tap fig 12 A Turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Reduced rate position The flame should not be too low the lowest small flame s...

Страница 12: ...vices The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate table also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas BURNER ARRANGEMENT ON THE HOT PLATE TABEL FIG 13 BURNERS GAS NORMAL PRESSURE mbar NORM...

Страница 13: ...ap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean the cone and its housing using a cloth soaked in diluent Lightly spread the cone with the relative grease Fit the cone back in place operate it several times and then remove it again Eliminate any excess grease and check that the gas ducts have not become clogged Fit all pa...

Страница 14: ... supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 18 and comply with the recommendations given in paragraph 8 TYPE OF HOT PLATE TYPE OF CABLE SINGLE PHASE POWER SUPPLY Gas hot plate H05 RR F Section 3 x 0 75 mm 2 ...

Страница 15: ...DATA ON THE DATA LABEL 2 BURNERS G30 LPG 30 mbar G20 NATURAL 20 mbar G110 TOWN 15 mbar Tot Nom L P G gas rate 9 5 kW Tot Nom H K Towngas rate 10 0 kW Tot Nom L P G rate 691 g h G30 Voltage 220 230 V Frequency 50 Hz ...

Страница 16: ...16 TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION ...

Отзывы: