Bertazzoni P7C01G9XT Скачать руководство пользователя страница 3

3

USE

1) TRADITIONAL BURNERS

A  diagram  is  screen-printed  above  each  knob  on
the  front  panel.  This  diagram  indicates  to  which
burner  the  knob  in  question  corresponds. After
having opened the gas mains or gas bottle tap, light
the burners as described below:

- automatic electrical ignition

Push  and  turn  the  knob  corresponding  to  the
required burner in an anticlockwise direction until it
reaches the full on position (large flame fig. 1), then
depress the knob.

- Lighting  burners  equipped  with  flame  failure

device

The  knobs  of  burners  equipped  with  flame  failure
device  must  be  turned  in  an  anticlockwise  direction
until they reach the full on position (large flame fig. 1)
and  come  to  a  stop.  Now  depress  the  knob  in
question  and  repeat  the  previously  indicated
operations.
Keep  the  knob  depressed  for  about  10  seconds
once the burner has ignited.
In  case  of  accidental  extinguishment  of  the  flame,
disengage the ignition by rotating the knob to the off
position. Wait at least 1 minute before re-igniting the
flame. 

HOW TO USE THE BURNERS

Bear  in  mind  the  following  indications  in  order  to
achieve maximum efficiency with the least possible
gas consumption:
- use  adequate  pans  for  each  burner  (consult  the

following table and fig. 2).

- When  the  pan  comes  to  the  boil,  set  the  knob  to

the reduced rate position (small flame fig. 1).

- Always place a lid on the pans.
- Use only pan with a flat bottom.

“DUAL” BURNER:

separate  regulation  of  the  inner  and  outer  rings  (in
practical terms, a dual burner controlled by a single
knob),  offering  very  flexible  use  thanks  to  the
possibility to light either the inner flame only or the
whole  burner  (inner  and  outer  flame  at  the  same
time).

LIGHTING AND USING THE “DUAL” BURNER

Stand the pan on the burner before lighting.

Despite  being  controlled  by  a  single  knob,  the
“DUAL” burner can be used in two different ways.

A) - Using the complete burner:
starting from the off position ● You must first press
the  knob,  simultaneously  turning  it  anti-clockwise,
until  the  indicator  points  to  the  maximum  delivery

position 

obtaining the maximum flow capacity of

both flames.
When the flames are lit, keep the knob pressed for
a few seconds, until the device automatically keeps
the burner lit.
It  is  now  possible  to  regulate  the  intensity  of  the
flame  by  turning  the  knob  anti-clockwise  (from  the
maximum  flow  capacity  position  of  the  inner  and
outer  flames  to  the  maximum  flow  capacity  of  the
inner flame and the minimum of the outer flame.
To  turn  off  the  burner,  turn  the  knob  clockwise,
realigning the indicator with the ● off symbol.

B) - Using the inner flame only:
after  lighting  the  burner  and  regulating  the  inner
flame  to  maximum  flow  capacity  and  the  outer
flame  to  minimum  flow  capacity  as  described
above,  turn  the  knob  anti-clockwise  until  it  clicks
once.  The  inner  flame  is  now  at  maximum  flow
capacity while the outer flame is turned off.
Continue turning anti-clockwise to regulate the inner
flame to the minimum flow capacity.

Turning off:
to  turn  off  the  burner,  turn  the  knob  clockwise,
realigning the indicator with the ● off symbol.

Once the “DUAL” burner is operating in either of the
two  modes  described,  it  is  possible  to  swap  from
one  mode  to  the  other  by  simply  pressing  and
turning the knob to the position required.

Содержание P7C01G9XT

Страница 1: ... of the instruction manual and on the appliance itself The manufacturer shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance Model P7C01CONXF The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors the designs in the figures are purely indicative The Manufac...

Страница 2: ...pport 4 Burner n 1 control knob 5 Burner n 2 control knob Attention this appliance has been manufactured for domestic use only and it employment by private person DESCRIPTION OF HOBS TYPE PCZ 90 A P7C01G9XT P9C01G9X7 A B P9C01G9X7 860 450 P7C01G9X7 780 450 DIMENSIONS HOBS in mm ...

Страница 3: ...g very flexible use thanks to the possibility to light either the inner flame only or the whole burner inner and outer flame at the same time LIGHTING AND USING THE DUAL BURNER Stand the pan on the burner before lighting Despite being controlled by a single knob the DUAL burner can be used in two different ways A Using the complete burner starting from the off position You must first press the kno...

Страница 4: ...d should be immediately removed from this before it is opened If the appliance has a glass lid this could shatter when the hot plate becomes hot Always switch off all the burners before closing the lid The machine must not be used by people including children with impaired mental or physical capacities or without experience of using electrical devices unless supervised or instructed by an expert a...

Страница 5: ...ty with current law on the protection of health and the prevention of environmental pollution by making its dangerous parts harmless especially for children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage resulting from improper incorrect or unreasonable use Durin...

Страница 6: ... clean rag Burnt or soiling may be removed with a special razor scraper fig 6 be aware that the razor can cause wounds Marks of liquid overflowed from the pot can be removed using vinegar or lemon Pay attention to not let fall sugar or element with sugar In this case turn the switch off and clean the surface with hot water and the razor blade scraper After a period of time may appear metal reflex ...

Страница 7: ...ance and contact qualified personnel Never leave the packaging materials cardboard bags polystyrene foam nails etc within children s reach since they could become potential sources of danger The measurements of the opening made in the top of the modular cabinet and into which the hot plate will be installed are indicated in either fig 7 Always comply with the measurements given for the hole into w...

Страница 8: ...perfectly matches the outer perimetral edge of the crystal The ends of the strips must fit together without overlapping Evenly and securely fix the seal to the crystal pressing it in place with the fingers Insert the hooks into their relative housings and fix them to the body using screws G fig 10 Fix the appliance in the hole made on the furniture and lock it with the proper screws F of the fixin...

Страница 9: ... hot plate correspond to those of the gas and electricity mains in the home A label on the appliance indicates the regulating conditions type of gas and working pressure Gas connection must comply with the pertinent standards and provisions in force When gas is supplied through ducts the appliance must be connected to the gas supply system with a rigid steel pipe The joints of this pipe must consi...

Страница 10: ...ricity main install an omnipolar circuit breaker between the appliance and the electricity main This circuit breaker should be sized in compliance with current installation regulations Remember that the earth wire must not be interrupted by the circuit breaker For optimum safety the electrical connection may also be protected by a high sensitivity differential circuit breaker You are strongly advi...

Страница 11: ... beside the tap fig 12 or inside the shaft In any case to access to regulation it can be done trought the insertion of a small screwdriver D beside the tap fig 12 or in the hole C inside the shaft of the tap fig 12 A Turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Reduced rate position The flame should not be too low the lowest small flame s...

Страница 12: ...vices The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate table also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas BURNER ARRANGEMENT ON THE HOT PLATE TABEL FIG 13 BURNERS GAS NORMAL PRESSURE mbar NORM...

Страница 13: ...ap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean the cone and its housing using a cloth soaked in diluent Lightly spread the cone with the relative grease Fit the cone back in place operate it several times and then remove it again Eliminate any excess grease and check that the gas ducts have not become clogged Fit all pa...

Страница 14: ... supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 18 and comply with the recommendations given in paragraph 8 TYPE OF HOT PLATE TYPE OF CABLE SINGLE PHASE POWER SUPPLY Gas hot plate H05 RR F Section 3 x 0 75 mm 2 ...

Страница 15: ...DATA ON THE DATA LABEL 2 BURNERS G30 LPG 30 mbar G20 NATURAL 20 mbar G110 TOWN 15 mbar Tot Nom L P G gas rate 9 5 kW Tot Nom H K Towngas rate 10 0 kW Tot Nom L P G rate 691 g h G30 Voltage 220 230 V Frequency 50 Hz ...

Страница 16: ...16 TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION ...

Отзывы: