CHARCOAL FILTER
Charcoal Filter, which was installed in your over the range
microwave, is used for nonvented, recirculated installation.
The filter should be changed every 6 to 12 months depending
on use.
1. Disconnect power to the oven at the circuit breaker panel
or by unplugging.
2. Remove the three louver mounting screws and push down
carefully on the tab at each end of the louver to disengage
it. (See illustration.)
3. Pull the louver away from the unit.
4. Change the charcoal filter.
5. Carefully push the louver back into place (engaging both
the bottom and top tabs) and replace the screws removed
in step 2.
REPLACING FILTER
REPLACING OVEN LIGHTS
LIGHT BULBS
1. To replace light bulbs, first disconnect power to the oven
at the circuit breaker panel or by unplugging.
2. To release cover, remove the screw on the light cover.
(See illustration.)
3. Replace light bulbs with equivalent watt bulb available
from your Bertazzoni Authorized Servicer or parts
distributor. Bulbs are also available at most hardware
stores or lighting centers. DO NOT USE A BULB LARGER
THAN 30 WATTS.
4. Close light cover and secure with screw removed in step
2.
CAUTION
— Light cover may become very hot. Do not touch
glass when light is on.
Light cover
Screw
Light bulbs
Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for one minute at HIGH 100%.
• Does the oven light come on?
YES _______
NO _______
• Does the cooling fan work?
YES _______
NO _______
(Put your hand over the rear ventilating openings.)
• Does the turntable rotate?
YES _______
NO _______
(It is normal for the turntable to turn in either direction.)
• Is the water in the oven warm?
YES _______
NO _______
If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker. If they are functioning
properly, CONTACT YOUR NEAREST BERTAZZONI AUTHORIZED SERVICER.
A OVER THE RANGE MICROWAVE should never be serviced by a “do-it-yourself” repair person.
NOTE:
If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 15 and cancel.
SERVICE CALL CHECK
louver
charcoal filter
(white side faces front)
screw
screw
bottom tab
top tab
screw
16
17
OTX_Use & Care.indd 17
2/25/11 8:15 AM
Содержание KO30 PRO X
Страница 20: ...OTX_Use Care indd 18 2 25 11 8 15 AM ...
Страница 38: ...36 OTX_Use Care indd 36 2 25 11 8 15 AM ...
Страница 39: ...OTX_Use Care indd 37 2 25 11 8 15 AM ...