Sensor Selection
Thermostat Programming
Date & Time Settings
The thermostat is factory preset to use the room and floor temperature sensors. The following options are available.
To change, press
M
for 3 seconds then
M
once more. Option can then be selected by the
+
/
-
buttons.
Your new thermostat has the following 3 modes. To manually select a specific mode press
M
.
Whilst the thermostat is operating in any of the modes above, the temperature can be manually altered by pressing the
+
or
–
buttons. The set temperature will then revert back to the pre-set level at the next change of mode.
To set the correct date & time press and hold for 3 seconds. Minutes will flash, press
+
/
–
to alter.
Press once again to alter hours (
24 hour clock
). Press once again to change week day.
The numbers from
1
to
7
at the top of the screen represent
Monday
to
Sunday
.
If this thermostat is to be used with any under floor heating system designed for floor coverings other than ceramic, porcelain or stone floor
tiles, the ‘floor sensor only’ option should be selected.
The (Comfort) , (Energy save) , and (Holiday) modes all need to be checked to ensure that the operating temperatures do not
exceed the values given by your heating / floor covering supplier. These temperature levels can be amended by holding for 3 seconds.
The first value that can be changed is the holiday mode. Press once more (quickly) to amend the energy save value, and once more for the
comfort value.
*
rS
FS
rFS
Room sensor
ONLY
Room and
floor sensor
Comfort mode
Energy-saving
mode
Holiday mode
Floor Sensor
Heating will be switched on by the thermostat when the room temperature falls below the programmed temperature.
There is NO LIMIT on the temperature the floor can reach.
Select this mode to turn the under floor heating on. The heating will operate at the preset temperature.
To alter the preset temperature hold for 3 seconds then press again twice. Factory preset temperature : 25˚C
Select this mode to turn the under floor heating down to a lower preset temperature. This temperature can be set
low enough to mean the heating is effectively turned off. To alter the preset temperature hold for 3 seconds
then press once again. Factory preset temperature : 15˚C
Select this mode to set the heating to a very low level whilst the room in unoccupied for a long period of time.
This mode should be selected to avoid frost damage whilst on holiday. To alter the preset temperature hold
for 3 seconds. Factory preset temperature : 5˚C
Heating will be switched on by the thermostat when the floor temperature falls below the programmed temperature.
*
Heating will be switched on by the thermostat when the room temperature falls below the programmed temperature. The
thermostat will cut power to the heating if the floor reaches a temperature higher than the programmed level. This is facto-
ry set at 65˚C This can re-programmed by the user at a level between 30˚C - 80˚C. RECOMMENDED MAX: 40˚C
Voltage: AC230V ± 10% 50/60HZ
Power Consumption: 5W
Setting Range: 5 ~ 30ºC
Floor overheating Protection: 30 ~ 80˚C (factory set @ 65˚C)
Protective housing: IP20
Housing Material: ABS + PC fire-resistant
Certification: CE
Floor Sensor: Rubber-Thermoplastic NTC 10K Sensor
Internal Sensor: NTC 10K
Technical Data