After you have finished connecting your jumper whips you can tuck them back into the table
trough, a concealed under mounted storage system, and move on to connecting your next
table.
To connect two adjacent Traction tables with the modular
connectors from separate power units, you must lift the cord
pass flap first then pull the leg cover out of the leg upright.
This will give ample room for the large modular connector to
pass from the storage trough.
Starter Table
Left Power Infeed
Left Power Add-On
Leg Cover
Add-on Table
Dual Under Mount Power Module and Connection
Installation Accessories
Connection Instructions
Traction offers a unique proprietary under mount power solution allowing quick and easy “daisy chaining” of tables. For the dual under mount
configuration, up to 4 tables may be connected to a single power infeed. The dual under mount power configuration uses a (1) receptacle and
(1) dual port USB module that comes mounted at the edge of the table. The power assembly and the Traction tables are UL 962 and CSA
22.2, No. 203.2 approved. The illustration below is of a Traction starter table which must be specified to begin a run.
Contains (1) 15 Amp receptacle and (2) amp USB port for
each power module.
A modular connection to help the user connect multiple work
surfaces.
Control module with 10’ grounded plug. Allows users to
connect up to 8 power/data centers off of one feed.
(4) Dual power tables.
A plug designed to be inserted into a receptacle in one
position only
.
When starting to connect your power you first need to identify your starter table SKU (pictured above is a starter table, found with a power
module control unit and grounded plug). Next you will want to gang your starter table with your first add-on table using the separately
purchased ganging brackets. To power the add-on table, pull the long modular connector wire from the starter table through the wire
management clips. Locate the modular connector near the edge of the adjacent table trough. Match the keying, indicated by the arrows on
the modular connects, and press the connectors together. Repeat for all tables in line, up to (8) power modules.
Dual Under Mount Power Module
Modular Connector
Power Module Control Unit
Power Module Wiring
B
C
D
Attaches to the bottom of the table, helps secure whips
when connected. Approved for GSA.
Wire Management Clip
E
A
Cord Pass Flap
Note: All power and wiring is pre-installed on starter and add-on
tables. Specify a right or left power infeed for the starter and add-on
table configurations.
4
dual under mount power
traction electrical installation instructions