12
13
1. Hold the plug-in coupling [15] and pull and simultaneously rotate its outer ring.
(Fig. 11)
► The plug-in coupling [15] is disconnected from the plug-in nipple [16] on the de
-
vice.
2. Pull up the red button on the safety valve [10] until all excess pressure is released from
the tank.
(Fig. 3)
3. Lock the pump handle in place [11].
(Fig. 4)
4. Unscrew the pump [2] from the tank [1].
(Fig. 5)
5. Wipe off the device with a moist cloth.
6. Wind the hose [5] around the tank and connect the plug-in coupling [15] to the plug-in
mandrel [18] of the water pressure tank.
(Fig. 12)
7. For drying and storing the water pressure tank, keep it in a dry place protected from
sunlight and freezing temperatures.
1. Connect the plug-in coupling [15] of the water pressure tank to the plug-in nipple [16]
on your device (Fig. 11)
2. Activate the ball valve [17]. (Fig. 11)
► The liquid starts to be supplied.
The amount of liquid can be regulated via the ball valve [17] on the device (e.g.
drill).
3. If the pressure drops below 1 bar (min. 0.5 bar), pump again.
(Fig. 10)
4. If the tank is empty, refill.
(→ See chapter entitled “Preparation”)
+
After usage
Observe the instructions in the section entitled “Safety”.
Observe the instructions in the section entitled “Safety”.
Use
Care and maintenance
After using the device 50 times or at least once a year:
• Disassemble the pump [2] and grease the diaphragm [20].
(Fig. 13 -14
)
• Grease the O-ring [19].
(Fig. 14)
Observe the instructions in the section entitled “Safety”.
Observe the legal requirements of your country for accident prevention and
check the device in regular intervals.
If there are no special rules, we recommend you have the device examined
externally by a competent professional every 2 years and subject it to an internal
inspection every 5 years. We would be happy to provide you with an inspection
schedule in German or English:
GB
IRL
AUS
USA
NZ
CDN
IND