Tank [1] with pump [2] and spare-parts pouch [3], instructions for use [4], hose [5]
(Fig. 1)
isual inspection:
Are tank [1], pump [2] and hose [5] undamaged?
(Fig. 1)
Pay special attention to the connections between the tank – hose and to the condition
of the pump thread and hose.
No leaks:
Pump up the empty device to 2 bar.
► The pressure must not decrease more than 0.5 bar within 30 minutes..
Function:
Pull the red button on the safety valve [10].
(Fig. 3)
► The pressure must dissipate.
+
1. Screw the hose [5] tightly into the outlet port [7].
(Fig. 2)
Note the location of the spigot [8] in order to be able to insert the lock.
2. Insert the lock [9].
(Fig. 2)
► The lock closes and the hose is secured from unscrewing out of the tank.
+
All excess pressure must be released from the device.
+
Making preparations
Observe the instructions in the section entitled “Safety”.
The device must be in an upright position.
If filling the tank from a water line, ensure that the line or a hose does not project
into the tank.
1. Pull up the red button on the safety valve [10] until all excess pressure is released from
the tank.
(Fig. 3)
2. Press the pump handle [11] down and turn it counterclockwise.
► The pump handle is locked in place.
(Fig. 4)
3. Unscrew the pump [2] from the tank [1].
(Fig. 5)
To ensure the pump remains clean during storage, we recommend you attach the
pump [2] to the pump holder [6]. (Fig. 6)
4. Add the liquid to the tank [1].
(Fig. 6)
5. Check the level[13] on the hose [5].
(Fig. 7)
+
Move the transparent hose [5] on the tank [1] from top to bottom several times (the
liquid level in the hose and tank is equalized). The liquid level [13] visible in the
hose [5] then corresponds to the level in the tank which can be read off the scale
[12]. (Fig. 7)
6. Screw the pump [2] into the tank [1].
(Fig. 8)
7. Swivel in the pump holder [6].
(Fig. 8)
8. Press the pump handle [11] down and turn it clockwise.
► The pump handle is unlocked.
(Fig. 9)
9. Generate pressure (approx. 2 bar) in the tank [1]
(Fig. 10)
.
The maximum pressure should not exceed 6 bar (red line on the pressure gauge
[14], Fig. 10). If the maximum pressure is exceeded, the safety valve will engage
and release the excess pressure..
10. Press the pump handle [11] down and turn it counterclockwise.
► The pump handle is locked in place.
(Fig. 4
)