background image

 

S 201                                                                                                                                                                                                                  01-07  

14

ATTENTION 

SAFETY CHECK

 

Before termination of the start up you need to 
do a safety check to see if the opener stops 
and reverses correctly according to the EU 

norms (EN 12453) when hitting an obstacle (max. force 
= 150 N which corresponds to 15 kg, above an opening 
of 50 mm).  This check is necessary for security of 
persons and objects. This security check and force 
measurement may only be done by a professional. At 
obstacle detection the door has to stop and reverse. If 
the door does not run the desired path or if the door 
does not reverse at obstacle detection, the force and 
path programming procedure needs to be repeated. If 
the force level at cut-off is either too low or too high, 
you have to adjust the force accordingly via the digital 
potentiometer. Then repeat the test.  
If after these corrections the door still does not stop 
and reverse according to the valid norms, the door 
may not be operated with the garage door opener. 
 
 

WARNINGS! 

Please attach warnings visibly and close to the opener. 

 

Maintenance 

We recommend double check of the complete plant (door + 
opener) by a professional once a year. Force cut-off, con-
nected safety devices and function of the mechanical 
emergency lock need to be checked every 4 weeks. Even-
tually occurred errors must be corrected immediately by a 
professional. 
 

You can test the force cutoff by putting a piece of 
wood (of min. 5 cm height) on the ground in the travel 
range of the door (Fig. 27) and then close the door with 
the GDO. When hitting the obstacle the door has to 
stop and reverse. 

 

 

Please only use max. 24V/15W (E14) light bulbs for 
replacement purposes. 

Batteries and light bulbs do not fall under warranty. 

 

 

Dismounting and disposal 

At dismounting and disposal the according local safety 
and disposal regulations are to be followed. 
 

 

Disconnect the operator before 

opening the housing 230V ~!!!  

and remove the light bulb.

 

Содержание S 201-60

Страница 1: ...S 201 01 07 1 Instruction manual S 201 Please keep this manual in a safe place B 190 045 GB ...

Страница 2: ...S 201 01 07 2 Technical data ...

Страница 3: ...S 201 01 07 3 ...

Страница 4: ...S 201 01 07 4 ...

Страница 5: ...S 201 01 07 5 ...

Страница 6: ...S 201 01 07 6 ...

Страница 7: ...mity has been issued Warranty The manufacturer assumes no warranty and product liability if installation was incorrectly performed or any change was made to the drive without the latter s prior consent Mounting may only be performed according to the assembly guidelines The mounting or additional use of other parts jeopardizes the safety of the drive and is therefore prohibited Instructions for the...

Страница 8: ...l Then fix the drive head with the provided screws 14 Mark the middle of the door Measure the width of the door and mark the middle of the door at the lintel and on the ceiling of the garage 15 16 Determination of the necessary height The rail has to be mounted on such a height that between the highest door point a the highest point that the door can reach during the movement and the lower edge of...

Страница 9: ...p of the garage door opener it is necessary to release the trolley and open and close the door completely by hand The trolley may not touch the motor head when the door is open and it may not touch the idler unit when the door is closed ...

Страница 10: ...ramming mode you have got the possibility to reverse the path direction by carrying out the following steps Press button S and keep pressed Press button L additionally If there is no door reaction pull mains plug and reconnect after approx 1 min then start programming once more ATTENTION DANGER During the automatic path programming of the opener the safety reversing function or safety devices are ...

Страница 11: ...e single functions HINT During the programming mode LED red and yellow are blinking rotationally and indicate the chosen menu point numbers of blinking signals red LED and the adjusted status numbers of blinking signal of yellow LED ...

Страница 12: ... system manual Repeat the Programming of the transmitter with additional PICO transmitter Erasure of a single transmitter only for radio system PICO 868 5 MHz if you install a different radio system please follow the instructions of the radio system manual Erasure of all transmitters only for radio system PICO 868 5 MHz if you install a different radio system please follow the instructions of the ...

Страница 13: ... emergency stop has been activated or jumper is missing on NOT terminal eliminate the interruption a start command will start the operator again 1x flashing safety devices photo cells or optoelektronic safety barrier have been actuated resp are not correctly activated eliminate the interruption a start command will start the operator again 2x flashing force cut off overload try to start the operat...

Страница 14: ... does not stop and reverse according to the valid norms the door may not be operated with the garage door opener WARNINGS Please attach warnings visibly and close to the opener Maintenance We recommend double check of the complete plant door opener by a professional once a year Force cut off con nected safety devices and function of the mechanical emergency lock need to be checked every 4 weeks Ev...

Страница 15: ... Motor does not start running Check if the Hall sensor cable is connected in the correct way at motor and at logic board Radio system PICO 868 5 MHz 2 channel 4 channel Application remote control for garage door and gate openers Technical data Frequency 868 5 MHz Coding KEELOQ Rolling Code System pre programmed by the factory Each receiver has a max capacity of 28 transmitters which can be program...

Страница 16: ...S 201 01 07 16 Conformity ...

Отзывы: