background image

PF-2 Fluoride and Arsenic Reduction Elements 

 

Priming Tips 

      1.  With the blue caps in place, wash the exterior of each PF-2   

 

 

element with water and dishwashing soap. 

      2.  With clean hands, remove one blue cap from the end of a PF-2  

 

 

element. It does not matter which blue cap is removed.

      3.  While holding the PF-2 element under your sink faucet,       

 

 

slowly turn on the cold water and fill the PF-2 element with  

 

 

water   (about ½ cup is needed).  Then turn off the water.

      4.  Replace the blue cap on the PF-2 element and shake it vigorously 
 

to help loosen any manufacturing dust that may be trapped within    

 

the element. Gently tapping the PF-2 element on the counter a few   

 

times will also help to loosen any excess manufacturing dust.

      5.  Remove both blue caps from the ends of the PF-2 element and  

 

 

empty out any residual water.

      6.  Place the tan rubber priming button onto one end of the PF-2  

 

 

element and align the hole of the element with the hole of the  

 

 

priming button.

      7.  Press the priming button up against the sink faucet so the priming    
 

button creates a seal between the faucet and the PF-2  

 

 

 

element. Place your thumb on top of the faucet to apply more  

 

 

pressure, creating a better seal. 

      8.  Turn on the cold water slowly, allowing water to fill the cavity  

 

 

of the PF-2 element and discharge from the opposite end.    

 

 

Allow  water to flow for one to two minutes or 

until the water  

 

 

runs clear.

 

      9.  To determine if more priming is necessary, run additional    

 

 

water through the element and using a clear glass, collect the  

 

 

water   discharging from the opposite end. If the collected    

 

 

water still appears cloudy, continue priming until the water is  

 

 

clear. 

 

The priming process may need to be repeated more 

 

 

 

 

than once to completely remove any residual manufacturing

 

 

 

dust.

    10.  Turn the PF-2 element over to prime the other end, repeating             
 

steps 6 through 9. 

    11.  Repeat steps 2 through 10 for each additional PF-2 element.

Note:

 

 Do not discard the priming button or blue caps as you may need 

them in the future to re-prime the elements.

chambers can also be cleaned in the dishwasher but remove all parts and 
attachments first.  If you have a Berkey Light system, do not place any of 
its components in the dishwasher.  

Note

 If your Berkey system is filtering hard water, which is water with a 

high dissolved mineral content, scale from naturally-occurring minerals 
such as calcium may develop in the spigot and chambers after prolonged 
use. These deposits can be removed by soaking the affected components in 
a 50-50% vinegar and water mixture for about 15 minutes. Then wash 
with water and mild dish soap. Do not soak the Black Berkey Elements or 
optional PF-2 elements in the vinegar mixture.

Frequently Asked Questions (FAQS) 

Why does my Berkey system leak where the upper and lower cham-
bers fit together?

       •  There is no water-tight seal between the upper and lower    
 

chambers of the system because this type of seal would  

 

 

prevent gravity filtration.  Therefore water will leak from    

 

where the two chambers fit together if both the upper and    

 

lower chambers are full or nearly full of water.  To prevent   

 

overflow, it is recommended to empty the lower chamber    

 

completely prior to refilling the upper chamber.

       •

  If at any time you experie nce an issue with your system   

 

leaking water, discontinue use, empty the water from both the  

 

upper and lower chambers, and contact Customer Service. 

Why Does the Upper Chamber Still Contain Water After the Filtering 
Process? 

       •  The Berkey systems are gravity filters and as the water level   
 

in the upper chamber decreases the filtering process will  

 

 

naturally slow down because there is less water pressure  

 

 

available to force water through the elements. It is normal for  

 

one to two inches of water to remain in the upper chamber. 

10

13

Содержание Berkey Water Filter

Страница 1: ...er prior to assembling and using your Berkey water filter This booklet is a supplemental document only and is not meant to replace the manufacturer s instructions Your Berkey Water Purifier This bookl...

Страница 2: ...ved No part of this booklet including the interior and cover design may be reproduced or transmitted in any form by any means electronic photocopying recording or otherwise without the prior written p...

Страница 3: ...uestions FAQS 13 14 Guarantee Warranty 14 16 Returning Your Berkey Water Filter System 17 18 Parts and Accessories 19 22 Contact Information 23 For further assistance please contact Customer Service 1...

Страница 4: ...ated Base LED Lighted Base is optional and its own spigot See the table on page 4 for spigot assembly instructions Prices are subject to change without notice Upper Chamber for Berkey Lightt Lower Cha...

Страница 5: ...Diagram 2 Hole plugs are not included with the Travel Berkey Factory issued spigot washers that are included with all stainless steel systems Prices are subject to change without notice Sport Berkey W...

Страница 6: ...ge 4 for the factory issued spigots that are included with the stainless steel systems and the Berkey Light system Upgraded spigots like the Water View Spigot and the Stainless Steel Spigot will have...

Страница 7: ...ad the element wing nut 8 onto the stem of the Black Berkey Element 6 below the upper chamber and tighten securely by hand D Repeat steps A C until all Black Berkey Elements have been installed E Inse...

Страница 8: ...o begin dripping Maximum flow rate will be achieved after the initial 12 24 hours of use as micro air pockets within the purification elements are replaced with water B Remove the hex nut 15 and the s...

Страница 9: ...fication process leaving no odor or taste Black Berkey Purification Elements Priming Tips 1 To create a useful finger hold for priming screw the wing nut onto the end of the threaded stem of the Black...

Страница 10: ...n object such as a ceramic coffee cup on each stem to force the element body under the water Allow the elements to soak for several hours to fully saturate them New Millennium Concepts Ltd shall not b...

Страница 11: ...s on page 12 and then allow them to dry completely The drying process can vary from one day to one week depending on the humidity level in the air When dry store the elements in their original packagi...

Страница 12: ...lace Berkey system near a heat source or in direct sunlight Do not use elements to filter sea water or softened water Why is the Filtered Water Cloudy Cloudy filtered water may indicate the PF 2 eleme...

Страница 13: ...ver to prime the other end repeating steps 6 through 9 11 Repeat steps 2 through 10 for each additional PF 2 element Note Do not discard the priming button or blue caps as you may need them in the fut...

Страница 14: ...act Customer Service Storing the PF 2 Elements UNUSED The PF 2 elements can be stored indefinitely in their original packaging USED Place the PF 2 elements in a re sealable zipper storage bag and stor...

Отзывы: