background image

 

 

 
 

Thermostat NO contact with centre plate, time-controlled 

Thermostat NO contact with centre plate, time-controlled 

Order no.: 2044 xx

 

Operation and installation instructions 

1  Safety instructions 

Electrical equipment must only be installed and assembled by qualified electricians. 
Always follow the relevant accident prevention regulations. 

The device is compliant with the guidelines of the EN 60730 and works according to the 
mode of operation 1C. 

Failure to comply with these instructions may result in damage to the device, fire or other 
hazards. 

These operating instructions are an integral component of the product, and must be 
retained by the end user. 

2  Design and layout of the device 

(1)

(2)

(3)

(4)

(5)

(6)

(7)

 

Figure 1: Device overview 

(1) Display 

(2) Operating 

keys 

(3) Operating 

unit 

(4)  Plug-in contacts for insertion 

(5)  Frame (not included in delivery) 

(6)  Socket for plug-in contacts 

(7) Insert 

 

 
97-09920-000

 

 

Page 1/15 

10/2011

Содержание 2044 Series

Страница 1: ...mpliant with the guidelines of the EN 60730 and works according to the mode of operation 1C Failure to comply with these instructions may result in damage to the device fire or other hazards These ope...

Страница 2: ...ater is switched on if the room temperature falls below the preset default value Floor thermostat The floor temperature is controlled The heating is switched on if the room temperature measured by the...

Страница 3: ...s using the 9 10 push button if required and press Info OK 11 to confirm Settings The selection of the settings menus is confirmed Carry out further settings with the 9 10 push button and press Info O...

Страница 4: ...the morning and night setback Mon Fri Sat Sun Event C C 1 6 00 21 0 7 00 21 0 2 8 30 18 0 10 00 18 0 3 12 00 21 0 12 00 21 0 4 14 00 18 0 14 00 21 0 5 17 00 21 0 17 00 21 0 6 22 00 15 0 Sat 23 00 Sun...

Страница 5: ...USER SETTING with push button 9 10 and press OK to confirm see operating thermostat G 1 PROGRAM SELECT ONE is displayed Press OK The number of the active program flashes Using select the desired progr...

Страница 6: ...me in the display is saved as the start time of the next interval If flashes in the display then the following event is on the next weekday If OK is pressed the display for the start time changes to t...

Страница 7: ...ters of the set program day profile The presettings of the program correspond to the current day program of Monday Set temperature and events confirm each setting by pressing OK Activation with confir...

Страница 8: ...e electrician Select YES NO heating off on press OK to confirm Display of function 16 OFF Switch on controller again Select any function via the menu or keep Menu s pressed down for 10 s G5 SUMMER WIN...

Страница 9: ...R TEMPERATURE Only when using as floor temperature controller Activating the display of the floor temperature as information number The display C is hidden Factory setting NO normal temperature displa...

Страница 10: ...To enable optimum room temperature control using the internal sensor the installation location selected should allow free air circulation not be located behind curtains cupboards shelves etc not be ex...

Страница 11: ...ipe so that it can be replaced later The wire of the temperature sensor supplies mains voltage and can be extended to 50 m using suitable wires To avoid signal disturbances do not lay the wire of the...

Страница 12: ...Operation H1 APPLICATION Selecting between the thermostat processes according to heating type ROOM Room thermostat FLOOR Floor thermostat LIMITER Room thermostat with limiter Factory settings ROOM Whe...

Страница 13: ...ve is opened daily at 10 00 for the time set here in minutes Factory setting 3 min Set opening time press OK to confirm H6 FROST PROTECTION Setting the frost protection mode and temperature When frost...

Страница 14: ...itch off voltage and switch on again ERR EXT SENSOR Failure short circuit of the external temperature sensor Replace temperature sensor Display range exceeded fallen short of 6 Appendix 6 1 Specificat...

Страница 15: ...vironment It is not possible to enter any data Cause 1 Key lock G6 is active Cancel key lock The desired temperature cannot be set Cause 1 Temperature limit G7 prevents the desired setting Reset tempe...