background image

Electrical

7

Disconnect power before working on pump, motor, pressure switch, or wiring. 

Hazardous voltage. Can shock, burn, or kill. Connect ground

wire before connecting power supply wires. Use the wire size (including
the ground wire) specified in the wiring chart. 
If possible, connect the
pump to a separate branch circuit with no other appliances on it. 

Explosion hazard. Do not ground to a gas supply line.

WIRING CONNECTIONS

Fire hazard. Incorrect voltage can cause a fire or seriously

damage the motor and voids the warranty. The supply voltage must be
within ±10% of the motor nameplate voltage.

NOTICE: Dual-voltage motors are factory wired for 230 volts. If necessary,
reconnect the motor for 115 volts, as shown. Do not alter the wiring in sin-
gle voltage motors.

Install, ground, wire, and maintain your pump in compliance with the
United States National Electrical Code (NEC) or the Canadian Electrical
Code (CEC), as applicable, and with all local codes and ordinances that
apply. Consult your local building inspector for code information.

Figure 6: Motor wiring connections through Pressure Switch. Match motor voltage to line voltage.

Your Motor Terminal Board (under the motor end cover)
and Pressure Switch look like one of those shown below.
Convert to 115 Volts as shown. Do not change motor

wiring if line voltage is 230 Volts or if you have a single
voltage motor. Connect power supply as shown for your
type of switch and your supply voltage.

A

B

L2

L1

A

B

L2

L1

A

B

L2

L1

A

B

L2

L1

230 Volt to 115 Volt Conversion, Spade Connector Type:

Move black wire 
from A to L1.

1.

1.

2.

2.

3.

3.

230 Volt to 115 Volt Conversion, Plug-in Type: 

Pull plug 
straight
out from 
terminal
board.

1.

1.

2.

2.

Plug in again
with arrow 
on plug 
pointing to
'115 Volts'.

3187 0398

A

L1

2

3

0

 

V

o

lt

s

1

1

5

 

V

o

lt

s

A

L1

2

3

0

 

V

o

lt

s

1

1

5

 

V

o

lt

s

A

B

L2

L1

A

B

L2

L1

Ground
Screw

Ground
Screw

Move white wire 
with black tracer 
from B  to A.

Change Complete:

Clamp the power cable to prevent strain 
on the terminal screws.

Connect the green (or bare copper) ground wire 
to the green ground screw.

Motor wires connect here.

Clamp the power cable to prevent strain 
on the terminal screws.

Connect the green (or bare copper)  ground wire 
to the green ground screw.

Motor wires connect here.

3187 0398

Power supply wires connect here. 
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw. 
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter 
which one). Connect the white (neutral) wire 
to the other screw. Cap any remaining 
black or red wires.

Power supply wires connect here. 
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw. 
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter 
which one). Connect the white (neutral) wire 
to the other screw. Cap any remaining 
black or red wires.

Содержание 10HN Series

Страница 1: ...stems Installation Operation Parts For further operating installation or maintenance assistance Call 1 800 363 PUMP 7867 1998 PRINTED IN U S A BE424 Rev 6 11 98 Series HN and SN 1800 Courtney Park Dri...

Страница 2: ...ouch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump...

Страница 3: ...keley Wicor dealer as soon as possible after the dis covery of any alleged defect Berkeley Wicor will subsequently take corrective action as promptly as reasonably possible No requests for service und...

Страница 4: ...s large as the suction port on the pump include a check valve if your pump is not equipped with one see Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the...

Страница 5: ...pipe The suction pipe should be at least as large as the suction port on the pump Step 2 Assemble a foot valve and suction pipe see Figure 3 Make sure that the foot valve works freely Use teflon tape...

Страница 6: ...ize must be at least as large as the discharge port Step 3 Remove the 1 8 NPT pipe plug from the pump Air Volume Control AVC port see Figure 5 Run tubing from the pump s AVC port see Figure 5 to the p...

Страница 7: ...Connect power supply as shown for your type of switch and your supply voltage A B L2 L1 A B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connector Type Move black wire from A to L1...

Страница 8: ...ode provided by the power company or the hydro authority Step 4 Connect the power supply wires to the pressure switch as shown in Figure 6 You have just completed the wiring for your pump Please go to...

Страница 9: ...3 min utes stop the pump and remove the fill plugs Refill the pump and piping You may have to repeat this several times in order to get all the trapped air out of the piping A pump lifting water 25 m...

Страница 10: ...N20 34 N20 34 10 Quick Connect 1 4 NPT 1 U11 217P U11 217P U11 217P 11 Pump Body Assembly 1 N176 43G N176 43GB N176 43GB 11A Venturi 1 N32P 66 N32P 75 N32P 75 11B Nozzle 1 N34P 17 N34P 21 N34P 21 12...

Страница 11: ...zle 1 J34P 44 J34P 44 12 Quick Connect 1 4 NPT 1 U11 217P U11 217P 13 Pipe Plug 1 4 NPT Hex Hd 4 U78 941ZPV U78 941ZP 14 Pump Body Assembly 1 N176 44G N176 44GA 15A Capscrew 3 8 16 x 1 1 2 Lg 2 U30 76...

Страница 12: ...lace check valve or foot valve Pipes are frozen Thaw pipes Bury pipes below frost line Heat pit or pump house Foot valve and or strainer are Raise foot valve and or strainer above bottom of water sour...

Отзывы: