3.
While the DF antenna is pointing at the potential source, re-set the Coarse Scale Maximum Hold
marker by pressing the “-↓-” button (arrows 1 in Figures 8 and 14). This will make the DF bar-
chart read maximum level (i.e. 0 to +1 on the DF Scale”) to help the user make small
adjustments to his/her intermediate heading to “lock-in” on the actual orientation of the
source.
4.
Walking slowly in the same heading, scan the unit again for maximum signal in the same
manner, while the signal level registered on the coarse bar chart increases.
5.
Keep walking in the same direction and repeat Steps 3 and 4 for increased signal till the source is
within arm's reach of the Wolfhound-PRO.
Method 2: “Triangulate” with Two (or more) LOPs
This method helps the user rapidly “triangulate” the approximate location of source by determining
two (or more) LOPs of the source from two (or more) positions on the floor (see Figure 27).
source
Point 1
Point 2
X
X
Figure 27. “Triangulating” the Source on Two LOPs