Espar Heater Installation
3-11
Run Heater Unit Power Cable
to
NITE Plus
Batteries
Take the heater unit power cable, run it under
the truck (attach with zip ties where
necessary) over to the
NITE Plus
batteries.
Strip back outer cover to expose two inner
wires.
Attach Connectors
Strip end off brown wire. Before stripping
red wire, put the housing for the fuse bracket
on, and pull the red wire through. Now strip
the end of the red wire, attach fuse bracket
and crimp down. Pull red wire back into fuse
bracket housing. Push rubber seal into place.
Attach ring terminal to ground wire and
crimp.
Attach Wires to
NITE Plus
Batteries
Connect heating unit ground wire to ground
terminal of
NITE Plus
batteries. Connect
heating unit positive wire to positive terminal
of
NITE Plus
batteries. Insert 20 amp fuse
into fuse bracket. Tighten all connections.
YOU CAN NOW RECONNECT THE
TRUCK’S BATTERIES TO TEST THE
SYSTEM.