10
EN
Important
In some cases of mistake message, to swith off the unit keep the On/Off
button
pushed till the screen switches off.
!
Hours de functioning and switching off from 0 to 9 hours. On 0 hour, it does not temporise, it
is in manual functioning
F0
.
To select hours, user will employ
-
+
keys.
Choose hour which appears on display, 1H (one hour), 2H (two hours)....9H (nine hours),
and push
On/Off
select
F4
ó
F0
, equipment will be working during selected time and
will stop when this time period is over.
F2
Time programming
It indicates temperature inside vehicle. In this functioning mode, equipment is switched off.
F1
Digital thermometer module
The condenser fan and compressor connect and disconnect automatically when the chosen
temperature is reached. (
e.g. chosen temperature 23º, the compressor and the condenser
fan disconnect at 21º and reconnect at 24º
).
Error messages
If when equipment is switched on, it makes continuous noises, it means that
keyboard is badly connected or not connected.
E0
- Return air sensor failure.
- Low battery, less than 22.8V.
E2
- Condenser or blower fan failure.
E3
-
Compressor failure (Causes: engine, wiring, connector, lack or excess of charge)
E5
- Compressor electronic module failure due to heating.
E6
- Anti-ice probe failure.
!
Содержание Bycool Dinamic 1.1