8. Periodic maintenance and servicing
In order to ensure fault-free performance of the unit, observe the below listed
instructions relating to periodic checks and maintenance.
-
Clean the external surfaces,
every 500 working hours
especially those of the cooler and
compressor cylinders.
(made by the user)
-
Tension drive belts, replace
if worn excessively.
every 2000 working hours
or once a year
if booster doesn't work 2000 per one year
-
Change oil.
-
Change oil filter.
(made by the authorized Berg
Kompressoren service)
every 2000 working hours
-
Change vent cartridge.
(made by the authorized Berg
-
Change the rings and valves.
-
Change non return valve cartridge.
Kompressoren service)
every 6000 working hours
(made by the authorized Berg
-
Change V-drive belts.
Kompressoren service)
Disconnect the unit from its power source and depressurise it to the atmospheric
pressure before you proceed with any of the above service operations.
9. Procedure for important service operations
9.1. Oil filter replacement
-
Turn off the booster compressor, close the valve on the discharge and
suction lines.
-
Turn off power supply and secure it against being reconnected by
unauthorized persons.
-
After waiting for at least 5 minutes, open the safety valve on the radiator
by pulling the stem.
-
Replacing the filter is best done using a special key.
-
Before screwing on the new filter, apply a thin layer of oil on the oil
filter gasket. Then screw on the filter by hand, without using any tool.
-
Slowly open the valves on the suction and discharge lines
-
Start the compressor and check for leaks.
Hot oil.