background image

   

Page | 4

 

 

IMPORTANT SAFEGUARDS

 

Before 

the ice maker is used, it must be properly positioned and installed as 

described in  this  manual,  so  read  the  manual  carefully  We  strongly 

recommend that you have a  professional  install  your  new  machine  The 

warranty may be affected or voided by an incorrect installation. To reduce 

the risk of fire, electrical shock or injury when using the ice maker, follow basic 

precautions, including the following:

 

 

        DANGER      

 

 

It is recommended that a separate circuit, serving only your ice maker, be provided Use 

receptacles that cannot be turned off by a switch or pull chain. 

 

 

Do not connect or disconnect the electric plug when your hands are wet. 

 

 

Never unplug the ice maker by pulling on the power cord. Always grip the plug firmly 

and pull straight out from the outlet. 

 

 

Never clean ice maker parts with flammable fluids. Do not store or use gasoline or 

other flammable vapors and liquids in the vicinity of this or any other appliance. The fumes 

can create a fire hazard or explosion.

 

 

Before proceeding with cleaning and maintenance operations, make sure the power line 

of the unit is disconnected and the water line is shut off (EXCEPTION: When cleaning the 

machine’s ice making and water systems).

 

 

Before operating, put all the enclosure panels back into their original places. 

 

 

Do not touch the evaporator with your hand when the machine is operating. 

 

 

Unplug the ice maker or disconnect power before cleaning or servicing Failure to do 

so can result in electrical shock or death. 

 

 

Do not attempt to repair or replace any part of your ice maker unless it is specifically 

recommended in this manual. A qualified technician should do all other servicing.

 

 

        WARNING      

 

 

Use two or more people to move and install ice maker Failure to do so can result in 

back or other injury. 

 

 

To ensure proper ventilation for your ice maker, the front of the unit must be completely 

unobstructed  Choose a well-ventilated area with temperatures above 50ºF (10ºC) and 

below 100ºF (38ºC) This unit MUST be installed in an area protected from the elements, 

such as wind, rain, water spray or drips. 

 

 

The ice maker should not be located next to ovens, grills or other sources of high heat. 

 

 

The  ice  maker  must  be  installed  with  all  electrical  and  water  connections  in 

accordance  with state and local codes A standard electrical supply against the 

nameplate rating, properly grounded in accordance with the National Electrical Code 

and local codes and ordinances is required. 

 

 

The fuse (or circuit breaker) size should be 20 amperes for the ice makers. 

 

 

It is important for the ice maker to be well leveled for proper operation  You may need to 

make several adjustments to level it. 

 

 

All installations must be in accordance with local plumbing code requirements. 

 

 

Make certain that the hoses are not pinched or kinked or damaged during installation. 

 

 

Check for leaks after connection. 

 

 

Although the unit has been tested at the factory, due to long-term transit and storage, 

the first batch of cubes must be discarded. 

 

 

Remove the packing materials and clean the ice maker before using. 

 

 

Turn on the water supply tap before switching on the ice maker  Never turn off the water 

supply tap when the ice maker is working. 

 

 

Except to take ice from the storage bin, keep the bin door closed in order to reduce ice 

melting and to promote proper ice formation. 

 

 

If the ice maker will not be used for a long time, before the next use it must be 

thoroughly  cleaned  Follow  carefully  any  instructions  provided  for  cleaning  or  use  of 

sanitizing solution  Do not leave any solution inside the ice maker after cleaning. 

 

 

DO NOT touch the condenser fins. The condenser fins are sharp and can be easily damaged.

 

 

Содержание BC1000N

Страница 1: ...ease contact 1 877 368 2797 FOR SOME MODELS the POWER SUPPLY CORD is NOT INCLUDED MUST HAVE A 3 PRONG GROUNDING PLUG 3355 Enterprise Avenue Suite 160 Fort Lauderdale FL 33331 BC360N BC360NH BC370N BC370NH BC500N BC500NH BC650N BC650NH BC1000N BC1000NH COMMERCIAL ICE MACHINE PLEASE READ CAREFULLY ...

Страница 2: ...pes 11 OPERATION Final Checklist before Operation 11 Control Panel Operation 11 12 How the Machine Makes Ice 13 Normal Sounds 13 Preparing the Ice Maker for Long Storage 13 CLEANING AND MAINTENANCE Exterior Cleaning 14 Interior Cleaning 14 Water Distribution Tube Cleaning 15 Ice Making System Cleaning 15 Condenser Cleaning 16 TROUBLESHOOTING GUIDE 17 TROUBLESHOOTING 18 Berg reserves the right to m...

Страница 3: ...N means that failure to heed this safety statement may result in minor or moderate personal injury or property or equipment damage All safety messages will alert you to what the potential hazard is tell you how to reduce the chance of injury and let you know what can happen if the instructions are not followed NOTE IMPORTANT SAFETY INSTRUCTIONS WARNING Toreduce the risk of fire electric shockor in...

Страница 4: ...e maker Failure to do so can result in back or other injury To ensure proper ventilation for your ice maker the front of the unit must be completely unobstructed Choose a well ventilated area with temperatures above 50ºF 10ºC and below 100ºF 38ºC This unit MUST be installed in an area protected from the elements such as wind rain water spray or drips The ice maker should not be located next to ove...

Страница 5: ...her end When moving the ice maker be careful not to damage the power cord Extension Cord Because of potentialsafetyhazards undercertainconditions itis stronglyrecommended thatyou do not use an extension cord with this ice maker Major Features 1 Completely automatic operation 2 Easy read screen Displays operational status reminders and alerts 3 The fan motor responds to the ambient temperature If r...

Страница 6: ...or products manufactured by Berg that have been altered in any way including the use of any parts and or other not specifically approved by The Legacy Companies Berg reserves the right to changes and or improvements at any time Specifications and designs are subject to without notice Component Information Top panel Water distribution tube Evaporator Water pump Floater valve Water tank Water curtai...

Страница 7: ...nections in accordance with state and localcodes Installation of the ice maker requires a cold water supply inlet of 3 8 9 5 mm soft copper tubing with a shut off valve The ice maker requires a continuous water supply with a minimum pressure of 15 psig and a static pressure not to exceed 80 psig To ensure proper ventilation for your ice maker you need keep the front of the unit completely unobstru...

Страница 8: ...Page 8 INSTALLATION CLEARANCE TOP VIEW of ICE MACHINE REAR VIEW of ICE MACHINE ...

Страница 9: ...e production will be less than expected and operation will be noisy ELECTRICAL REQUIREMENTS Before you move your ice maker into its final location Be sure you have the proper electrical connection Refer to the nameplate rating at theleft of theicemachine tomake sure proper voltage properly grounded in accordance with National Electrical Code and local codes and ordinances is required The ice maker...

Страница 10: ...cked on top of another machine a stacking kit will need to be installed Refer to the installation instructions included with the stackingkit WATER SUPPLY The water supply should be ready at the point of installation The water supply pressure should be a minimum of 15 psig with a static pressure not more than 80 psig A wall outlet directly behind the ice maker will make installation easier Tools re...

Страница 11: ...ne 9 Is the ice cube machine plugged in 10 Have you turned on the main water supply and the tap 11 Have you checked for leaks at all water supply connections Control Panel in the front panel of the machine You will find the control panel in the front panel of the machine This control panel offers four pressure sensitive buttons and a LCD display screen 1 ON OFF Button Powers the ice machine 2 BinF...

Страница 12: ... When ice cubes are taken out from the ice storage bin releasing the water curtain the machine will judge the status for three minutes During this period the LCD screen will display the words of Bin Full Release and 3 Min To End Bin Full Release flashes until the words 3 Min To End changes to 0 Min To End At this time the ice maker will start to make ice automatically 7 TO CLEAN THE MACHINE press ...

Страница 13: ...al 20 has been set at the factory for optimum performance You can change it according to the quality of water ICE BRIDGE SIZE ADJUSTMENT GUIDE 1 Press and hold the ADJUST button for at least 3 seconds The unit will enter the Ice Size Adjustment mode and the words Ice Adjust display on the LCD Screen 2 While in the Ice Size Adjustment mode press the Clean button or the Mode button for the desired i...

Страница 14: ...nedinthewatertank Asthewaterflows to the freezing evaporator surface the water freezes and sticks to the ice cube molds During the ice making process fresh water enters the water tank continuously as the water from the tank freezes continuously on theevaporator NORMAL SOUNDS Your new ice cube machine may make sounds that are unfamiliar to you Most of the new sounds are normal Hardsurfaceslikethefl...

Страница 15: ...lly convenient to sanitize the tank after the ice making system has been cleaned and the ice storage bin is empty The ice storage bin should be sanitized occasionally Follow these steps to clean the tank and the bin 1 Disconnect power to the unit 2 Using a knifepoint or similar tool t o remove the plastic covers on the top and bottom front panel 3 Using a Phillips screwdriver remove the screws the...

Страница 16: ... or how effective your filtration maybe Withhardwaterof15to20grains gallon 4to5grains liter youmayneedtoclean thesystem as often as every 3 months 1 Using tools to remove the plastic cover and screws fixed in front panel swing the front panel open 2 Make sure all ice is off evaporator If ice is being made initiate harvest or wait for cycle completion then turn machine off at the power switch 3 Rem...

Страница 17: ...R SERVICE If the unit appears to be malfunctioning read through the OPERATION section of this manual first If the problem persists check the Troubleshooting Guide on the following page The problem may be something verysimplethatcanbesolvedwithoutaservicecall WARNING The ice machine cleaner contains acids DO NOT use or mix with any other solvent based cleaner products Use rubber gloves to protect h...

Страница 18: ...ce from ice storage bin Normal condensation on the door or some water together with ice Take care when you take out ice Water supply connection leaks Tighten fitting See Connecting the water line Cubes are partially formed or white at the bottom Not enough water in the water trough Check if the water supply pressure is below 15 psig Check water supply filter may be restricted Check for a water lea...

Отзывы: