Mynute Green E C.S.I.
23
Mynute Green E 25 C.S.I.
Seasonal ambient heating
energy efficiency class
A
Water heating energy efficiency class
A
Parameter
Symbol
Value
Unit
Parameter
Symbol
Value
Unit
Nominal output
Pnominale
20
kW
Seasonal ambient heating
energy efficiency
η
s
94
%
For boilers for ambient heating and combined: Useful heat output
For boilers for ambient heating and combined: efficiency
At nominal heat output and at
high temperature operation (*)
P4
19.6
kW
At nominal heat output and at
high temperature operation (*)
η
4
88.4
%
At 30% of the nominal
heat output and at low
temperature operation (**)
P1
6.6
kW
At 30% of the nominal
heat output and at low
temperature operation (**)
η
1
98,7
%
Auxiliaries electrical consumption
Other parameters
At full load
elmax
28.0
W
Heat loss in standby mode
Pstby
45.0
W
At partial load
elmin
10.1
W
Pilot flame energy consumption
Pign
-
W
In Standby mode
PSB
2.4
W
Annual energy consumption
QHE
60
GJ
Internal sound output level
LWA
49
dB
Nitric oxide emissions
NOx
26
mg/kWh
For combined heating appliances
Declared load profile
XL
Heating water energy efficiency
η
wh
85
%
Daily electrical energy
consumption
Qelec
0.183
kWh
Daily fuel consumption
Qfuel
22.687
kWh
Annual electrical energy
consumption
AEC
40
kWh
Annual fuel consumption
AFC
17
GJ
(*) High temperature operation: 60°C at boiler return line and 80°C at boiler delivery line.
(**) Low temperature operation: For condensing boilers 30°C, for low temperature boilers 37°C, for other heating appliances 50°C return line
temperature.
Mynute Green E 30 C.S.I.
Seasonal ambient heating
energy efficiency class
A
Water heating energy efficiency class
A
Parameter
Symbol
Value
Unit
Parameter
Symbol
Value
Unit
Nominal output
Pnominale
24
kW
Seasonal ambient heating
energy efficiency
η
s
94
%
For boilers for ambient heating and combined: Useful heat output
For boilers for ambient heating and combined: efficiency
At nominal heat output and at
high temperature operation (*)
P4
24.5
kW
At nominal heat output and at
high temperature operation (*)
η
4
88.2
%
At 30% of the nominal
heat output and at low
temperature operation (**)
P1
8.2
kW
At 30% of the nominal
heat output and at low
temperature operation (**)
η
1
98,7
%
Auxiliaries electrical consumption
Other parameters
At full load
elmax
37.0
W
Heat loss in standby mode
Pstby
45.0
W
At partial load
elmin
12.8
W
Pilot flame energy consumption
Pign
-
W
In Standby mode
PSB
2.4
W
Annual energy consumption
QHE
75
GJ
Internal sound output level
LWA
51
dB
Nitric oxide emissions
NOx
24
mg/kWh
For combined heating appliances
Declared load profile
XL
Heating water energy efficiency
η
wh
85
%
Daily electrical energy
consumption
Qelec
0.183
kWh
Daily fuel consumption
Qfuel
22.893
kWh
Annual electrical energy
consumption
AEC
40
kWh
Annual fuel consumption
AFC
17
GJ
(*) High temperature operation: 60°C at boiler return line and 80°C at boiler delivery line.
(**) Low temperature operation: For condensing boilers 30°C, for low temperature boilers 37°C, for other heating appliances 50°C return line
temperature.