Mynute Green E C.S.I. - R.S.I.
140
Mynute Green E C.S.I. - R.S.I.
141
[EN] - Multi-row wiring diagram
“L-N” POLARISATION IS RECOMMENDED
Bianco = White
Blu = Blue
Giallo = Yellow
Grigio = Grey
Marrone = Brown
Nero = Black
Rosa = Pink
Rosso = Red
Verde = Green
Viola = Violet
Arancione = Orange
A
Gas valve
B
3.15 AF fuse
C
External probe
D
Room thermostat (voltage free contact
input)
G
S.BOLL - Water tank probe
H
T.BOLL/POS - Water tank thermostat/
domestic water time programmer
AKL05 GAR
●
Control card with built-in digital
display
P1
●
Potentiometer to select off – summer –
winter – reset / heating temperature
P2
●
Potentiometer to select domestic hot
water set point, enable/disable pre-heating
function (C.S.I.)
P3
●
Thermoregulation curves pre-selection
P4
●
Not used
JP1
●
Enable front knobs for calibration only of
maximum heating (MAX_CD_ADJ)
JP2
●
Heating timer reset
JP3
●
Enable front knobs for calibration in
service (MAX, MIN, MAX_CH, RLA)
JP4
●
Not used
JP5
●
Heating only operation with provision for
external storage tank with thermostat (JP8
inserted) or probe (JP8 not inserted)
JP6
●
Enable night-time compensation function
and pump in continuous mode
JP7
●
Enable standard / low temperature
systems management
JP8
●
Management of external storage tank
with thermostat enabled (jumper inserted)/
Management of external storage tank with
probe enabled (jumper not inserted)
CN1-CN15
●
Connection fittings (CN7 zone
valve kit)
S.W.
●
Chimney sweep, interruption of the
venting cycle and calibration when enabled
E.R.
●
Flame detection electrode
F1
●
3.15A T fuse
F
●
3.15A F external fuse
M2
●
Terminal board for external connections:
low temperature thermostat/general alarm
M3
●
Terminal board for external connections:
230 V
M4
●
Terminal board for external connections:
water tank probe/ water tank thermostat or
POS
M6
●
Terminal board for external connections:
Open therm / external probe / room
thermostat
P
●
Pump
PWM
●
PWM signal
OPE
●
Gas valve operator
V Hv
●
Fan power supply 230 V
V Lv
●
Fan control signal
3V
●
3-way servomotor valve
E.A.
●
Ignition electrode
TSC2
●
Ignition transformer
P.A.
●
Water pressure switch
P.AR.
●
Air pressure switch
T.L.A.
●
Water limit thermostat
S.F.
●
Flue gas probe
S.M.
●
Delivery temperature probe on primary
circuit
S.R.
●
Return temperature probe on primary
circuit
T.B.T.-A.G.
●
Low temperature thermostat -
General alarm
20 R.S.I.
marone
CN3
blu
V Hv
1
2
7
1
CN9
P.A.
2
3
1
bianco bianco
viola
viola
rosso rosso
M4
-t°
3V
2
N
1
San.
3
Risc.
nero (san.)
marrone (risc.)
blu
3
1
CN4
CN8
CN7
1
12
CN11
1
4
CN10
1
7
CN9
CN6
CN5
CN12
1
CN4
1
3
CN3
1
2
CN2
1
6
AKL05 GAR
CN1
1
FA1
FA2
JP1
JP2
JP3
JP4
JP5
JP6
JP7
JP8
CN15
P3
P2
P1
CN13
CN14
SW1
P4
E.R.
arancione
M6
nero
nero
nero
arancione
arancione
rosa
rosa
-t°
OT+
3.15A T
F1
blu marrone
giallo/verde
N
F
CN1
3
1 2
E.A.
TSC2
rosso (+)
blu (HS)
rosa (PWM)
grigio (-)
CN10
V Lv
1
4
1
12
CN11
bianco bianco
S.M.
-t°
rosso rosso
-t°
S.F.
grigio
grigio
nero
blu
blu
bianco
-t°
3
1
P.AR. T.L.A.
giallo
giallo
S.R.
T.B.T / A.G.
rosso
M2
6
1
marrone
blu
2
1
3
5
4
1 2
4
3
OPE
OPE
rosa
blu
P
blu
marrone
marrone
N
L
F
230 V
M3
marrone
blu
marrone (+)
blu (-)
1
2
PWM
CN12
CN2
G
H
B
C
D
A