6
Fig. 8
Fig. 6
Fig. 9
A
!
!
!
!
!
!
!
!
After making hydraulic connection, fill the heating system
in.
This operation is to be performed
when the system is cold, as
follows:
- unscrew the automatic air
discharge valve cap (A) by two
or three turns
- open the filling cock, external to
the system until water gauge
pressure reaches approx. 1 bar
(fig.8).
When the plant is full, close the
filling cock.
The boiler is equipped with an
effective air separator, therefore no
manual operation is required.
The burner only starts when the
air discharge phase is completed.
Heating system emptying
Empty the system as follows:
- turn the boiler off
- connect a small rubber pipe to
boiler exhaustion valve (B)
- untighten the valve
- empty the lowest parts of the
system.
6.
FUME EXHAUSTION AND
COMBUSTION AIR SUCTION (R.A.I.)
Fig. 7
5.
HEATING SYSTEM FILLING AND
EMPTYING
Air bleeding valve
Water gauge
ATTENTION
The safety valve exhaustion
is to be connected to a proper
collection system.
The manufacturer is not
responsible for any flooding
possibly provoked by the
activation of the safety valve
This boiler is equipped with a system controlling proper
exhaustion of fume thermostat-combustion products (fig.
9); in case of abnormality, this
system immediately stops
appliance operation.
Proper fume exhaustion control
device must always operate.
Safety devices are only to be
replaced by Technical Service
exclusively using original
components.
After repair, perform an ignition
test and check proper operation
of fume exhaustion thermostat.
Exhaustion duct and flue union
must comply with national and
local Standards and/or
regulations.
Using rigid ducts is compulsory,
junctions between elements
must be tight and all
components must be resistant to
temperature, condensates and
mechanical stresses.
Non-insulated exhaustion ducts
can be dangerous.
Combustion air and room
ventilation opening must comply
with technical standards.
Do not obstruct or reduce
dimensions of installation room
ventilation openings.
Filling cock
Fume
thermostat
Fig. 10
Top view
Measures
in mm
B
Содержание Kompakt R.A.I. Series
Страница 67: ...67 1 A 3 4 B 3 4 C 3 4 1 2 Kompakt R A I 1 Kompakt 4 Kompakt R S I 2 3 R A I B11 BS 14 R S I C 14 A B C...
Страница 68: ...68 4 5 4 Kompakt 230 50 85 R A I 125 R S I EN 60335 1 L N CEI EN 3 1 5 2 L N 3...
Страница 69: ...69 8 6 9 A 1 8 B 6 R A I 7 5 9 A B 10...
Страница 70: ...70 13 11 12 7 R S I C 60 100 80 A 0 85 1 0 5 0 85 L 45 90 1 1 4 25 A 14...
Страница 72: ...72 8 Kompakt G20 GPL G30 G31 17 18...
Страница 75: ...75 19 20 C OFF RESET OFF RESET 9 10 OFF RESET 5 6 21 20 2 1...
Страница 91: ...91 R A I R S I...
Страница 93: ...93 A B C D...
Страница 97: ...97...
Страница 98: ...98 cod 10022769 Ed 2 27 03...