12
EXCLUSIVE GREEN E C.S.I. - R.S.I.
* DHW values refer to C.S.I. models. For R.S.I. models: DHW values refer only if a water tank is connected.
** Average value among various sanitary running conditions.
*** Tested with Ø60-100 concentric - lenght 0,85m - water temperature 80-60°C.
(+) The installation of this product is allowed only in the destination Countries contained in the data plate, regardless of the present translation lan-
guage.
Flow rates (G31)
CH
DHW
CH
DHW
CH
DHW
CH
DHW
CH
DHW
Air capacity
Nm
3
/h 24,819 31,024 31,024 37,228 37,228 42,937 24,819 31,024 37,228 42,937
Fumes capacity
Nm
3
/h 26,370 32,963 32,963 39,555 39,555 45,620 26,370 32,963 39,555 45,620
Mass flow (max-min)
g/s
9,297-
1,859
11,621-
1,859
11,621-
2,092
13,946-
2,092
13,946-
2,324
16,084-
2,324
9,297-
1,859
11,621-
1,859
13,946-
2,324
16,084-
2,324
Fan performance
Fan residual head without pipes
Pa
80
125
160
80
160
Fume exhaustion and air suction
concentric pipe
Diameter
mm
60 - 100
60 - 100
60 - 100
60 - 100
60 - 100
Max lenght
m
7,80
7,80
7,85
7,80
7,85
Loss for a 90°/45° bend
m
1,6/1,3
1,6/1,3
1,6/1,3
1,6/1,3
1,6/1,3
Hole in the wall
mm
105
105
105
105
105
Fume exhaustion and air suction
concentric pipe
Diameter
mm
80 - 125
80 - 125
80 - 125
80 - 125
80 - 125
Max lenght
m
20
20
14,85
20
14,85
Loss for a 90°/45° bend
m
1,5/1
1,5/1
1,5/1
1,5/1
1,5/1
Hole in the wall
mm
130
130
130
130
130
Fume exhaustion and air suction
separated pipe
Diameter
mm
80
80
80
80
80
Max lenght
m
50 + 50
50 + 50
38 + 38
50 + 50
38 + 38
Loss for a 90°/45° bend
m
1,5/1
1,5/1
1,5/1
1,5/1
1,5/1
Forced open installation (B23P-B53P)
Diameter
mm
80
80
80
80
80
Max lenght
m
80
80
60
80
60
Loss for a 90°/45° bend
m
1,5/1
1,5/1
1,5/1
1,5/1
1,5/1
Nox
class 6
class 6
class 6
class 6
class 6
Emission values at maximum and minimum of
gas***
G20
G31
G20
G31
G20
G31
G20
G31
G20
G31
Maximum
CO s.a. lower than
p.p.m.
150
190
150
180
150
160
150
190
150
160
CO2
%
9,0
10,0
9,0
10,0
9,0
10,0
9,0
10,0
9,0
10,0
NOx s.a. lower than
p.p.m.
30
30
30
28
20
25
30
30
20
25
T fumes
°C
67
67
69
69
70
71
67
67
70
71
Minimum
CO s.a. lower than
p.p.m.
10
20
5
5
5
15
10
20
5
15
CO2
%
9,0
10,0
9,0
10,0
9,0
10,0
9,0
10,0
9,0
10,0
NOx s.a. lower than
p.p.m.
25
35
30
40
15
30
25
35
15
30
T fumes
°C
57
55
59
59
60
57
57
55
60
57
Содержание Exclusive Green E 25 C.S.I.
Страница 51: ...51 ESPAÑOL Posición abierta 1 3 4 5 2 6 A 7 9 D 11 10 8 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C ...
Страница 109: ...109 MAGYAR Nyitott állás 1 3 4 5 2 6 A 7 9 D 11 10 8 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C ...
Страница 138: ...138 EXCLUSIVE GREEN E C S I R S I Poziţie deschis 1 3 4 5 2 6 A 7 9 D 11 10 8 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C ...
Страница 167: ...167 SLOVENŠČINA Odprt položaj 1 3 4 5 2 6 A 7 9 D 11 10 8 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C ...
Страница 221: ...221 EXCLUSIVE GREEN E C S I R S I C S I E F E F G R S I 1 8 1 9 C S I 1 6 1 7 A E B D F D F C R S I C A A ...
Страница 225: ...225 EXCLUSIVE GREEN E C S I R S I ...
Страница 226: ......
Страница 227: ......