. MULTIGAS
TABLE
Parameters
Methane
Liquid gas
(G20)
Butane
Propane
(G30)
(G31)
C.A.I. - R.A.I.
Lower Wobbe index (15°C-1013 mbar)
MJ/m
3
S 45,67
80,58
70,69
Lower heat value
MJ/m
3
S 34,02
116,09
88
MJ/kgs
-
45,65
46,34
Supply nominal pressure (Extra EC countries)
mbar
20
28-30
37
(mm H
2
O) (203,9) (285,5-305,9)
(377,3)
Supply nominal pressure (MT)
mbar
30
(mm H
2
O)
(305,9)
Supply minimum pressure
mbar
13,5
(mm H
2
O) (137,7)
24 kW
C.A.I.
Main burner (12 nozzles)
Ø mm
1,3
0,77
0,77
CH maximum gas capacity
Sm
3
/h 2,82
- -
kg/h
-
2,10
2,07
DHW maximum gas capacity
Sm
3
/h 2,82
- -
kg/h
-
2,10
2,07
CH minimum gas capacity
Sm
3
/h 1,13
- -
kg/h
-
0,84
0,83
DHW minimum gas capacity
Sm
3
/h 0,88
- -
kg/h
-
0,65
0,64
Maximum pressure downstream CH valve
mbar
11,80
28,00
36,00
mm H
2
O 120,33
285,52
367,10
Maximum pressure downstream DHW valve
mbar
11,80
28,00
36,00
mm H
2
O 120,33
285,52
367,10
Minimum pressure downstream CH valve
mbar
2,10
5,00
6,70
mm H
2
O 21,41
50,99
68,32
Minimum pressure downstream DHW valve
mbar
1,30
3,10
4,00
mm H
2
O 13,26
31,61
40,79
28 kW
C.A.I. - R.A.I.
Main burner (14 nozzles)
Ø mm
1,3
0,78
0,78
CH maximum gas capacity
Sm
3
/h 3,37
- -
kg/h
-
2,51
2,48
DHW maximum gas capacity*
Sm
3
/h 3,37
- -
kg/h
-
2,51
2,48
CH minimum gas capacity
Sm
3
/h 1,48
- -
kg/h
-
1,10
1,09
DHW minimum gas capacity*
Sm
3
/h 0,92
- -
kg/h
-
0,69
0,68
Maximum pressure downstream CH valve
mbar
12,70
27,00
35,20
mm H
2
O 129,50
275,32
358,94
Maximum pressure downstream DHW valve*
mbar
12,70
27,00
35,20
mm H
2
O 129,50
275,32
358,94
Minimum pressure downstream CH valve
mbar
2,60
5,50
7,10
mm H
2
O 26,51
56,08
72,40
Minimum pressure downstream DHW valve*
mbar
1,00
2,30
2,90
mm H
2
O 10,20
23,45
29,57
*
DHW values refer to C.A.I. models.