1 | GENERAL INFORMATION
8
1.7
Technical specifications
Performance combined with BREVA IN
Model
9000-1
12000-1
18000-1
24000-1
Indoor unit
1 x 9000
1 x 12000
1 x 18000
1 x 24000
Cooling performance (1)
Capacity at rated air flow
kW
2,60
3,60
5,00
7,00
Absorbed power at rated air flow
kW
0,80
1,11
1,46
2,16
EER
kW/kW
3,23
3,23
3,41
3,23
Capacity at maximum air flow
kW
3,40
4,00
5,80
8,50
Absorbed power at maximum air flow
kW
1,40
1,50
2
2,90
Capacity at minimum air flow
kW
0,80
1
1,30
2,20
Absorbed power at minimum air flow
kW
0,30
0,30
0,40
0,70
Cooling energy data (2)
SEER
kW/kW
6,20
6,40
6,10
7,10
Energy class
A++
A++
A++
A++
Annual energy cons.
kWh/annum
147
197
287
350
Heating performance (3)
Capacity at rated air flow
kW
2,90
3,70
5,20
8,10
Absorbed power at rated air flow
kW
0,78
0,99
1,40
2,18
COP
kW/kW
3,71
3,71
3,71
3,71
Capacity at maximum air flow
kW
3,80
4,60
6,00
10,00
Absorbed power at maximum air flow
kW
1,40
1,50
2,50
2,90
Capacity at minimum air flow
kW
1
1,10
1,40
2,40
Absorbed power at minimum air flow
kW
0,30
0,40
0,52
0,70
Energy data for Average climatic profile (4)
Pdesign at -10 °C
kW
2,40
3,20
4,60
5,60
SCOP
kW/kW
4,10
4,10
4
4
Energy class
A+
A+
A+
A+
Annual energy cons.
kWh/annum
819
1092
1610
1963
Energy data for Warm climatic profile (4)
Pdesign at +2 °C
kW
2,00
2,80
4,60
5,60
SCOP
kW/kW
5,10
5,10
5,10
5,10
Energy class
A+++
A+++
A+++
A+++
Annual energy cons.
kWh/annum
549
769
1263
1537
(1) Outdoor air: 35 °C D.B., Indoor air: 27 °C D.B. / 19 ° W.B.
(2) In compliance with 626/2011 regulation
(3) Outdoor air: 7 °C D.B. / 6 °C W.B., Indoor air: 20 °C D.B.
(4) In compliance with EU 206/2012 regulation