background image

2 | INSTALLATION

12

2.4

Storage

If the product is stored in a room before installation check:

- there aren't continously operating ignition sources (open flames,

gas appliances, electric heaters,..) within a radius of 2.5 m.

- there is adequate ventilation

The product must be stored of according to the regulations in force.

2.5

Handling and removal of the packing

Before unpacking, personal protective clothing should be worn and
used transport means and tools suitable for the size and weight of
the unit.

Check refrigerant leak inside the packaging with a leak detector
suitable for the refrigerant used in the system.If a gas leak is
detected, probably the refrigerant circuit is damaged and the
product can't be installed; finally call Technical Service 

Product handling can also be done manually by grasping the handles
provided on the packaging.

1

Handles

2

Strapping bands

3

Document envelope and material supplied as kit

Follow the below instructions for packing removal and product handling:

- transport the equipment in the installation place
- cut strapping bands
- lift and remove the cardboard pack

The unit is supplied with the connections cover fixed to the unit with
adhesive tape to avoid damage during transport and handling
operations.
Before handling operations it is necessary to fix the connections cover to

the unit:

1

Adhesive tape

2

Connections cover

3

Fixing screw

4

Handles

- remove the adhesive tape
- unscrew the connections cover fixing screw from the unit
- position the connections cover

- Reassemble the fixing screws.
- handle the unit by grasping the handles provided.
- remove the document envelope

In manual operation it is compulsory to respect always the maximum
weight per person provided for by the national laws and standards.

Handle with care

The equipment must always be handled vertically

Do not tilt the equipment over 15°

The unit’s weight is concentrated on the compressors side
(connection covering side).

The packing material must not be disposed of in the surrounding
environment and must be kept out of children reach, as it can be
dangerous. It must be disposed of according to the regulations in
force.

2.6

Place of installation

The  location  of 

BREVA  EX 

devices  must  be  determined  by  the 

system's designer or by another competent person, and must take into

account the technical requirements, as well as any current local
regulations that require specific permits to be obtained. (e.g.: zoning,
architectural, environmental protection, etc.).
It is therefore recommended to obtain all the necessary permits before
installing the device.

is designed for outdoor installation. 

Avoid:

- positioning the unit in air shafts and/or basement window wells
- any obstacles or barriers that will cause the expelled air to

recirculate

- locations with aggressive or explosive atmospheres or with

inflammable fluids

- confined locations in which the device's sound levels might be

compounded by reverberations or resonances

- proximity to bedrooms and rooms for resting
- positioning in corners where dust, leaves, or any other materials

typically accumulate, which could compromise the device
efficiency by obstructing the airflow

- situations in which the air expelled from the device might enter the

habitation through doors or windows, thus creating an
inconvenience for the people inside

- situations in which the air expelled from the device will encounter

resistance from opposing winds

- direct exposure to sunlight and proximity to heat sources

Avoid placing the unit less than 1 metre away from radio and video
systems.

If the unit is installed in a windy location, fit an anti-wind grille to
protect the fan and check the correct functioning of the unit.

Decide where to place the unit considering the length of cooling lines
and the maximum difference of height allowed between the devices.

2.7

Recommended distances

The distances for the device installation and maintenance are shown in
the figure. The indicated spaces are necessary in order to prevent the
airflow from being blocked, as well as to allow normal cleaning and
maintenance operations to be carried out.

Содержание 20171581

Страница 1: ...Installer manual BREVA EX EN...

Страница 2: ...Thank you again and keep up the good work BERETTA S p A COMPLIANCE BREVA EX heat pumps are compliant with the following European Directives Low Voltage Directive 2014 35 EU Electromagnetic Compatibil...

Страница 3: ...3 Ordinary maintenance 3 4 Segnalazione di funzionamento e allarmi 4 DISPOSAL The following symbols are used on the product The R32 refrigerant gas is slightly inflammable and odourless Avoid proximi...

Страница 4: ...rigerant gas operate carefully so as to avoid damaging the gas circuit and the fin bank Do not place any inflammable object spray cans within a 1 metre radius from the air expulsion According to EU Re...

Страница 5: ...ti freeze sensor which transmits the temperature value as detected by the heat exchanger to the electronic board that is triggered when the heat exchanger is clogged by frost formations outdoor air te...

Страница 6: ...ling 10 Liquid line connection 16 Electric panel cover 5 Heat exchanger 11 Muffler 6 Electric fan 12 Filter MODEL 12000 1 1 Upper panel 6 Electric fan 13 Filter 2 Fan protection grille 8 Rotary compre...

Страница 7: ...16 Terminal board for electric connections 5 Handle for handling 11 Liquid line connection 17 Electric panel cover 6 Heat exchanger 12 Muffler MODEL 24000 1 1 Upper panel 6 Electric fan 11 Filter 2 Fa...

Страница 8: ...apacity at rated air flow kW 2 90 3 70 5 20 8 10 Absorbed power at rated air flow kW 0 78 0 99 1 40 2 18 COP kW kW 3 71 3 71 3 71 3 71 Capacity at maximum air flow kW 3 80 4 60 6 00 10 00 Absorbed pow...

Страница 9: ...um current consumption A 1 40 1 80 2 30 3 20 Electrical characteristics Power supply V Ph Hz 230 1 50 230 1 50 230 1 50 230 1 50 Compressor Compressor Tipo Rotary Rotary Rotativo Doppio Rotativo Doppi...

Страница 10: ...the air inside the rooms During the wintertime the heat pump extracts the thermal energy from the outdoor air and delivers it to the room air thereby heating it During the summertime the cycle is rev...

Страница 11: ...ion s book for the installer and for the Technical Service in English Warranty Spare parts labels energy label etichetta gas refrigerante contact sheet It is also supplied as kit Condensate discharge...

Страница 12: ...cking material must not be disposed of in the surrounding environment and must be kept out of children reach as it can be dangerous It must be disposed of according to the regulations in force 2 6 Pla...

Страница 13: ...osition so as to prevent the air flow from being blocked or install a roofing to protect it Adequate anti freeze systems should be used for installations in extremely cold areas where there is a possi...

Страница 14: ...turer shall bear no responsibility for any damages caused by incorrect system installation 2 10 Refrigerating connection The dimensions and positions of cooling connections are shown hereunder MODELLO...

Страница 15: ...lare connections Cooling lines must be as straight as possible and any necessary bends must have a radius grater than 40 mm Use clean hoses Make sure the inside is free of dust residues water Avoid th...

Страница 16: ...insulating material on the joints Pipe insulation Connection pipes must be thermally insulated to prevent dispersions of heat or formation of condensate 1 Gas pipe 2 Condensation discharge 3 Liquid p...

Страница 17: ...rating circuit as they can cause explosions reach a pressure equal to 0 3 Mpa wait 3 minutes check that the pressure has not dropped reach a pressure equal to 1 5 Mpa wait 3 minutes check that the pre...

Страница 18: ...pipes If the pressure has not risen again A Opening B Closing 1 Service connection blanking plug 2 On off valve shaft 3 Refrigerating pipe attachment 4 On off valve cover plug 5 Hex wrench remove the...

Страница 19: ...2 INSTALLATION 19 2 11 Wiring diagram MODEL 9000 1 MODELLO 12000 1 18000 1...

Страница 20: ...red with a separate electric circuit 1 Electric connection input position the system s main switch in the OFF position Wait 10 minutes before touching the device electric components To access the term...

Страница 21: ...For the sizing of the electrical power cables and safety devices use the following table Model 9000 1 12000 1 18000 1 24000 1 Electrical characteristics Protection factor IP X4 X4 X4 X4 Protection aga...

Страница 22: ...ds contact opening of at least 3 mm with adequate breaking power and differential protection installed near the equipment connect the device to a properly functioning earthing system make sure that th...

Страница 23: ...ted controls have problems turn the device off and call the Technical Service immediately Do not touch the device pipes to prevent potential burns Take anti static precautions in case of weather condi...

Страница 24: ...ck with a tester that the voltage between the power supply connectors of the main electronic board is lower than 10 Vdc Yearly operations The annual maintenance plan includes the following checks powe...

Страница 25: ...blinking After the LED switches off Wait 10 minutes before touching the device electric components Check with a tester that the voltage between the power supply connectors of the main electronic boar...

Страница 26: ...temperature sensor failure The alarm activates 4 minutes after the unit start After 3 consecutive interventions in 30 minutes the unit resets after problem resolution 14 Compressor suction overtemper...

Страница 27: ...shall be disposed of separately so as to recover and recycle them Refrigerant and oil must be recovered and not dispersed into the environment At the end of its service life the device shall be dispo...

Страница 28: ...1 277111 Fax 39 0341 277263 info berettaboilers com www berettaclima it As the manufacturer is constantly improving its products the aesthetic or dimensional features the technical data the equipment...

Отзывы: