48
Installation
6003884_0 – 22.08.2017
On the opposite side there is a DIP switch on a circuit board.
The setting of the DIP switch must match with the width of
the ceiling lift hood.
1
ON DIP
2 3 4
Width 95
1
ON DIP
2 3 4
Width 115
1
ON DIP
2 3 4
Width 135
☞
Make sure that the DIP switch is correctly set for the hood
width.
In order to access the DIP switch:
☞
Fold the faceplate down.
☞
Unscrew the trim panel on the side of the fan box.
☞
Use a size 2.5 Allen key to unscrew the screws in the side
part.
☞
Push the side part upwards.
☞
Pull the side part off to the side.
Checking the connection:
☞
Ensure that the extractor hood is switched off.
☞
Plug the mains plug into the socket.
If the device is not connected correctly, five beeps will sound.
☞
Correct the connection of the wires to terminals 1 and 2.
If the device is connected correctly, three will beeps sound.
☞
Make sure that the device can be disconnected on all
poles from the electricity supply after installation.
☞
Ensure that the extractor hood is reinstalled properly
(e.g. by attaching the side part and fitting the cover).
3.2.5
Check and carry out commissioning
D
ATTENTION!
Risk of disruptions due to moisture in the device!
If the device is moved from a cold environment into a hot one,
condensation may form inside.
☞
Wait about 2-3 hours before bringing the device into
service.
☞
Ensure that air outlets on the ceiling lift hood are not
closed or covered.
☞
Ensure that the extractor hood is configured correctly.
☞
Check that the ceiling lift hood is functioning correctly.
D
Содержание permalyt BUR BDL 115
Страница 52: ...6003884_0 22 08 2017 ...