25
Operation
6004067_a – 01.08.2018
EN
Touch
field
Function
If the changeover function is activated:
☞
Touch the touch field 1x.
Touch field illuminates dimly:
The device operates in exhausted air mode.
The wall box is opened.
The cleaned air is discharged outside.
Touch field illuminates brightly:
The device is operating in recirculated air mode.
The wall box is closed.
The cleaned air is discharged into the room.
4.3.3
Check filter filling indicator
The device has a check indicator in order to remind the
operator to change the filter filling. In recirculated air mode,
the check indicator flashes every 350 hours of operation.
The hours counter is started anew by switching off the check
indicator.
The check indicator is switched off in configuration mode.
D
“4.4 Configuration” (page 25).
Touch
field
Function
Touch field flashes:
The filter filling must be replaced.
D
“6.2.2 Replacing filter filing (with recirculating
and hybrid mode)” (page 28).
4.4
Configuration
Touch
field
Function
The device is switched on, the power stages
are not active.
☞
Touch the touch field 1x - for longer than
10 seconds.
The power level touch field flashes 5x.
The device switches to configuration mode.
The configuration mode is turned on.
To exit the configuration mode:
☞
Touch the touch field 1x.
The settings are now saved.
All operating symbols illuminate for 5 seconds.
The device is in normal mode again.
In the configuration mode, the following functions can be
activated or deactivated by touching the corresponding
touch fields.
Touch
field
Function
Effect lighting - no function.
As delivered, the touch field is turned off.
The touch field can be activated in
configuration mode.
☞
Touch the touch field 1x.
Touch field illuminates brightly:
The touch field does not have any function on
this device.
Extraction mode / recirculated air mode
changeover.
As delivered, the function is turned off.
☞
Touch the touch field 1x.
Touch field illuminates brightly,
touch field for recirculated air mode
illuminates dimly:
The changeover function is activated.
☞
Touch the touch field 1x.
Touch field illuminates dimly,
touch field for recirculated air mode is off:
The changeover function is deactivated.
Check filter filling indicator.
The function is set such that touch field
for recirculated air mode flashes every
350 operating hours.
The filter filling has been changed:
☞
Touch the touch field 1x.
Touch field illuminates brightly:
The hour counter starts anew, the touch field
for recirculated air mode is switched off.
Automatic run-on.
As delivered, the function is turned off.
☞
Touch the touch field 1x.
Touch field illuminates brightly:
Automatic run-on is activated.
Содержание Moveline BTH 100 ML