22

Operation

6005737_0 – 31.03.2021

4.3.4 

Filter filling indicator

The device has a check indicator in order to remind the 
operator to change the filter filling. In recirculated air mode, 
the check indicator flashes every 350 hours of fan operation. 
The hours counter is restarted by switching off the control 
indicator. 

The control indicator is switched off in configuration mode.

 

D

“4.4 Configuration” (page 22).

Touch 

field

Function

Touch field flashes:
The filter filling must be replaced.

 

D

“6.2.2 Replacing filter filling (with 
recirculating and hybrid mode)” 
(page 25).

4.4 

Configuration

Touch 

field

Function

The device is switched on, the power stages 
are not active.

 

Touch the touch field 1x - for longer than 
10 seconds.

The power level touch field flashes 5x.
The device switches to configuration mode. 

The configuration mode is turned on.
To exit the configuration mode:

 

Touch the touch field 1x.

The settings are now saved.
All operating symbols illuminate for 5 seconds.
The device is in normal mode again.

In the configuration mode, the following functions can be 
activated or deactivated by touching the corresponding 
touch fields.

Touch 

field

Function

 

Touch the touch field 1x.

The hob lighting switches on. 

 

Press the touch field again to start the 
colour cycle. 

After the touch field is released, the 
colour cycle stops and the selected colour 
temperature is saved.

Extraction mode / recirculated air mode 
changeover.

As delivered, the function is turned off. 

 

Touch the touch field 1x.

Touch field illuminates brightly,  
touch field for recirculated air mode 
illuminates dimly:
The changeover function is activated.

 

Touch the touch field 1x.

Touch field illuminates dimly,  
touch field for recirculated air mode is off:
The changeover function is deactivated.

Filter filling indicator.

The function is set such that touch field for 
recirculated air mode flashes every 350 fan 
operating hours.

When the filter filling has been changed:

 

Touch the touch field 1x.

Touch field illuminates brightly:
The hour counter starts anew, the touch field 
for recirculated air mode is switched off.

Automatic run-on.

As delivered, the function is turned off.

 

Touch the touch field 1x.

Touch field illuminates brightly:
Automatic run-on is activated.

Содержание BWH 90 GL

Страница 1: ...EN Wall hood Glassline EN Operating and installation instructions for the models BWH 90 GL 6005737_0 ...

Страница 2: ...uld result in serious injuries or death D CAUTION Notes with the word CAUTION warn of a situation that could result in minor injuries D ATTENTION Notes with the word ATTENTION warn of a situation that could result in damage to property or to the environment Symbol clarification text Handling requirement y Listing D Reference to another point in this document Reference to other documents that shoul...

Страница 3: ...11 3 5 4 Hanging the device in place 12 3 5 5 Connect accessories 14 3 5 6 Fitting the BackFlow port 14 3 5 7 Installing filter with recirculating and hybrid operation 15 3 5 8 Connecting exhaust air ducting with extracted air and hybrid mode 15 3 5 9 Establish electrical power supply 16 3 5 10 Mounting the chimney 16 3 5 11 Inserting lower section and separating unit 17 3 5 12 Check and carry out...

Страница 4: ...o safe use of the device y Users understand the hazards involved with the device y Children may not play with the device 1 3 General safety instructions D WARNING Hazard through a disregard of the operating and installation instructions This manual contains important information for the safe handling of the device Separate reference is made to possible hazards Read through this manual thoroughly F...

Страница 5: ...articles of dirt e g particles or grease and oil out of the air y The dirt particles are separated out and collected on the lower section and at the separating unit BackFlow technology optional y Condensate or droplet formation on the extractor hood e g if steam touches the cold surface is prevented by the ventilation of the hood underside y Part of the vented air quantity is blown from the front ...

Страница 6: ...e room or which is drawn into the room 2 2 3 Hybrid mode In hybrid mode it is possible to select flexibly between recirculated air mode and extracted air mode In extracted air mode the cleaned room air is routed to the outside through the wall box which opens automatically Extracted air mode is recommended in summer or with particularly intensive frying In recirculated air mode the wall box remain...

Страница 7: ... GL E02 Connection voltage 230V 50 Hz Total power 179W Fan power consumption 170W Lighting LED 8 4W 384 lx Colour temperature adjustable 2700 6500 K Width 900 mm Depth 520 mm Height in recirculated air mode with recirculated air filter BUF 150 710 1035 mm Height in recirculated air mode with recirculated air filter permalyt 825 1035 mm Height in extracted air mode 645 895 mm Height in hybrid mode ...

Страница 8: ...lead to hazardous situations e g in the handling of electrical power or gas Make sure that the requirements for the installation location are complied with y Do not install in potentially explosive atmospheres y With simultaneous use of a heating point which uses air from the room as its oxygen supply e g chimneys y A safety device is absolutely essential y The safety device must prevent gases bei...

Страница 9: ...ard due to improper installation When using the exhaust air ducting with other devices or when connecting an active exhaust air channel e g chimney gases or smoke can be drawn into the room Make sure that the requirements for the exhaust air ducting are complied with y The exhaust air ducting is used exclusively by this device y The exhaust air ducting is made of non combustible material in accord...

Страница 10: ... Make sure that the hob and other parts that could be touched have cooled down Protect the hob and other surfaces in the installation area e g with thick cardboard Ensure that the power supply is switched off and remains so Connect the power supply only when instructed to do so in the installation instructions If accessories e g wall box window contact switch are required for the installation Obse...

Страница 11: ... kitchen equipment Protect the cooled hob and other surfaces in the cooking area e g with thick cardboard Fold the lower section down Press the lower section at the side with both hands and draw it approx 10 mm back to unlatch it Move the lower section down in an arc and remove it to the front The separating unit is inserted and is held in the device by side hooks Pull the side hooks inwards on bo...

Страница 12: ...h gas hobs at least 650 mm Observe the specifications for the cooking appliances e g installation above a solid fuel stove Determine the hanging position Ensure that the chimney mount is correctly positioned y The chimney cannot be mounted if it falls below the required measurement 30 mm y Any irregularities e g in the ceiling can be compensated with slotted holes Make sure that the safety distanc...

Страница 13: ...weight If the device falls down serious injuries are possible Two persons are required to hang the device Ensure stable footing when hanging the device Ensure that no other people are in the working area D ATTENTION Danger of property damage through improper handling Hanging the device requires a great deal of physical exertion due to its size and weight If the device falls the device kitchen furn...

Страница 14: ...ction with special accessories of the manufacturer Connection with a PC or other devices is not permitted Wall box y The wall box is closed when the control contacts are open y The wall box is open when the control contacts are closed Window contact switch y The hood s fan is only operational when the window is open Safety device y The hood s fan is only operational when no critical under pressure...

Страница 15: ...the BackFlow port from above Ensure that the hybrid filter is correctly installed 3 5 8 Connecting exhaust air ducting with extracted air and hybrid mode Extracted air mode without BackFlow technology The BackFlow port is not used When connecting a flexible hose it is possible to use a tight fitting pipe as an intermediate piece Establish a chamfer on the inside of the exhaust air ducting Fit the ...

Страница 16: ...r of damage due to improper handling The body of the hood and the chimney could be damaged by movements during the installation Keep a distance between the chimney and the body of the hood Keep objects that could scratch the device far away from it e g tools belt buckles The chimney comprises two chimney ducts that slide inside one another There are two ventilation slots inside the inner chimney d...

Страница 17: ...slot with both hands Press the separating unit up until it latches into place Guide the lower section into the device from below until the guide pins of the lower section are in front of the guide grooves on both sides Pull the guide pins of the lower sections into the guide grooves Pull the lower section downwards until it latches into place Check that the lower section can be moved easily Pivot ...

Страница 18: ...Remove the protective film from the device Check that the mains plug is freely accessible or that an all pole isolating device min 3 mm contact gap is present Check that the mains cable and the electrical connection cable are not kinked crushed or damaged Ensure that air outlets are not closed or covered With recirculated air devices Make sure that the ventilation slots are free Make sure that the...

Страница 19: ...ing unit is used and the lower section closed y In recirculated air mode Do not cover the air outlets e g glasses plates on or in front of the ventilation slots Out flowing air must be able to escape through the ventilation slots without impediment Otherwise backpressure may form If the cooking vapours are no longer able to escape there is a danger of fire y With exhausted air or hybrid operation ...

Страница 20: ...y Power level 2 medium fan power y Power level 3 high fan power If the intensity of the cooking vapours does not subside switch to a higher power level Switch to the POWER level if frying Turn on the run on function when you have finished cooking D 4 3 1 Run on function page 21 Check the fresh air supply at regular intervals Use the device also to reduce other unpleasant smells Such as from y Onio...

Страница 21: ...d power level will flash 4 3 2 Hob lighting The hob lighting is fitted with energy saving LED lighting The lighting can be used at any time and independently of the fan The hob lighting is dimmable The colour temperature is set in configuration mode D 4 4 Configuration page 22 Touch field Function Press the touch field 1x in order to switch the hob lighting on or off Hold touch field down to start...

Страница 22: ...he configuration mode the following functions can be activated or deactivated by touching the corresponding touch fields Touch field Function Touch the touch field 1x The hob lighting switches on Press the touch field again to start the colour cycle After the touch field is released the colour cycle stops and the selected colour temperature is saved Extraction mode recirculated air mode changeover...

Страница 23: ...m the room The dirt particles are separated off and collected in the lower section and separating unit Before every cleaning Turn off the device Make sure that the hob and other parts that could be touched have cooled down D ATTENTION Danger of damage through improper cleaning Sharp edged objects abrasive or unsuitable cleaning agents can damage the device The following cleaning agents are unsuita...

Страница 24: ...t damp cloth or in a dishwasher Dry the lower section with a soft cloth Re attach the lower section D 3 5 11 Inserting lower section and separating unit page 17 Separating unit The separating unit is inserted and is held in the device by side hooks Pull the side hooks inwards on both sides Remove the separating unit Clean the separating unit e g in the dishwasher Clean the surfaces and edges on th...

Страница 25: ...ver open the fan housing 6 2 Maintenance 6 2 1 Changing the lamps The device is fitted with maintenance free LED lighting In the event of a fault Please consult your dealer or customer services 6 2 2 Replacing filter filling with recirculating and hybrid mode Odours are trapped in the filter filling in the recirculating air filter or hybrid filter The odour free cleaned room air is fed back into t...

Страница 26: ... the filter at least 30 mm Remove the filter to the front The replacement of the filter filling is carried out as described in the associated instructions Change the filter filling Clean the filter from the outside e g through extraction with a vacuum cleaner Attach the filter again D 3 5 7 Installing filter with recirculating and hybrid operation page 15 Mount the chimney D 3 5 10 Mounting the ch...

Страница 27: ...g with recirculating and hybrid mode page 25 Poor device performance y The recirculated air filter is clogged Replace the filter filling of the recirculated air filter D 6 2 2 Replacing filter filling with recirculating and hybrid mode page 25 y The hybrid filter is clogged Replace the filter filling of the hybrid filter D 6 2 2 Replacing filter filling with recirculating and hybrid mode page 25 y...

Страница 28: ...sical exertion due to its size and weight If the device falls the device kitchen furnishings and other objects could be damaged Cover the cooled hob Keep the installation area clear Disconnect all poles of the power supply for the device Pull out the mains plug Loosen the inner chimney duct from the chimney mount Lift the chimney away from the device Remove the chimney fastening If present Remove ...

Страница 29: ...ckaging is made from cardboard y The filling material and the insets are made from cardboard or polythene PE y The protective film and bags are made from polythene PE Dispose of the packaging in an environmentally friendly manner separated by materials 8 2 Dispose of the device D ATTENTION Risk of environmental damage due to improper disposal of the device The device is subject to the European Dir...

Страница 30: ...gy efficiency index EEI 53 3 EEI Hood Class A FDE Hood 29 3 FDE Hood Class A LE Hood 45 7 LE Hood Class A GFE Hood 96 3 GFE Hood Class A Flow rate in extracted air mode in m h Stage min to max 310 370 450 Stage Power Intense 560 Flow rate in recirculated air mode in m h Stage min to max 250 300 380 Stage Power Intense 470 Noise power level in extracted air mode in db A Stage min to max 54 60 64 St...

Страница 31: ... 80 9 0 Mon to Thu 08 00 17 30 hrs and Fri 08 00 16 30 hrs Fax 49 0 5971 80 80 9 10 Internet www berbel de email info berbel de Contact the manufacturer s customer support department There are several ways for you to contact our customer service Please select from the following options Tel 49 0 5971 80 80 9 0 Mon to Thu 08 00 17 00 hrs and Fri 08 00 15 00 hrs Fax 49 0 5971 80 80 9 10 email service...

Страница 32: ...6005737_0 31 03 2021 ...

Отзывы: