Warning
!
When servicing or replacing components that affect combustion, analyses and soot tests must be carried
out on the installation.
5. Burner servicing
5.1 Warning
Service must be carried out after 3,000 operating hours, or at least once per
year.
Only authorized personnel may perform service.
Before any type of service work is begun, switch of the power at the main
switch and shut off the oil.
Exercise caution as parts which are exposed when the burner is taken apart
can be hotter than 60°C. The installation engineer must be especially careful
to ensure that no electrical wiring or oil lines are pinched or damaged during
installation or service.
5.1.1 Service position
5.1.1.1 Service position 1
1.
Switch off the power at the main switch and disconnect the Eurostecker
from the burner.
2.
Undo the screw which fastens the burner front piece to the fan housing,
but only so much as to allow the fan housing to be removed from the
burner front piece.
3.
Remove the fan housing from the burner front piece and pull it
backwards until the combustion assembly is free of the burner front
piece.
4.
Suspend the fan housing by the fan housing attachment point (for
joining the front piece to the fan housing) on the screw (for joining the
front piece to the fan housing) as illustrated to the left. If necessary,
tighten the screw somewhat to ensure that the burner is suspended
safely.något för att få brännaren att hänga säkrare.
5.1.1.2 Service position 2
1.
Switch off the power at the main switch and disconnect the Eurostecker
from the burner.
2.
Undo the screw which fastens the burner front piece to the fan housing,
but only so much as to allow the fan housing to be removed from the
burner front piece.
3.
Remove the fan housing from the burner front piece and pull it
backwards until the combustion assembly is free of the burner front
piece.
4.
Turn the screw into the front piece until there is a gap of approx. 5 mm
between the metal and the screw head.
5.
Suspend the fan housing by the fan housing service attachment on
the screw used for joining the front piece to the fan housing, with the
motor upwards, as shown in the illustration to the left.