background image

17

 

Bentone B30A RME, B40A RME 

 

9.  FAULT LOCATION

9.1 

Burner will not start

Symptom

Motor starts 

Burner pre-ventilates

Flame formed

Burner trips

Motor starts 

Burner pre-ventilates

No flame formed

Burner trips

Causes

Unstable flame 

Excess air

Low oil pressure 

Incorrect combustion apparatus settings 

Flame monitor does not register light 

Defective flame monitor 

Defective oil burner control 

No oil 

False light 

No spark 

Remedies

Adjust the damper  

Check the oil pressure 

Check the nozzle in relation to the 

combustion apparatus dimensions and the 

ignition electrode position

Check the flame monitor is clean and can 

register light

Check with using new photocell 

Check using new oil burner control (Note: 

replacement of photocell recommended if oil 

burner control replaced)

Check the oil supply to the burner and that 

there are no air bubbles in the pump

Check function of solenoid 

Check flame monitor does not register 

ambient light 

Check high voltage wiring and ignition 

electrodes

Burner does not start

Burner pre-ventilates

Burner stops

Fuse blown 

Boiler thermostat has not reset 

Overheating protection has deployed

Defective preheater 

Defective oil burner control or  

flame monitor

No oil supply

Too great a pressure drop at brake plate 

Too strong draught prevents flame forming 

No spark 

Check and replace fuse as necessary. 

Investigate cause of fault 

Adjust thermostat 

Reset the overheating protection. 

Investigate the cause of its deploying.

Remedy fault

Check by replacing with new 

Check that tank, oil lines, solenoid valves, 

pump and nozzle are in good condition

Adjust the burner

Correct the boiler draught

Check the ignition transformer. Check the 

ignition electrode settings and ceramics

Burner pulsates at start with  

hot flue gases

Burner pulsates at start 

Too strong a draught

Too great a pressure drop at brake plate

Nozzle partially blocked

Oil pressure too low

Flue blocked or damaged

Fan wheel slipping on shaft

Pump coupling loose or worn

Preheater clogged

Delayed ignition

Too strong a draught

Too great a pressure drop at brake plate

Correct the boiler draught

Adjust the burner

Replace nozzle

Check and adjust

Check and correct

Check and tighten

Replace

Check ignition electrode adjustment 

(refer to technical data)

Check ignition electrodes  

not damaged

Check high voltage wiring

Check position of nozzle  

assembly adjustment

Correct the boiler draught

Adjust the burner

9.2 

Burner will not start after normal use

9.3 

Delayed ignition, burner starts; pulsation

Содержание B30A RME

Страница 1: ...Providing sustainable energy solutions worldwide 178 080 51 2015 03 11 Installation and maintenance instruction B30A RME B40A RME...

Страница 2: ......

Страница 3: ...3 GENERAL INSTRUCTIONS___________________________________ 7 4 MAINTENANCE OF OIL BURNER B30______________ 10 5 MAINTENANCE OF OIL BURNER B40______________ 11 6 OIL CIRCUIT DIAGRAM_____________________...

Страница 4: ...5 Ignition cable 6 Ignition transformer 7 Photo cell 8 Control box 9 Reset button 10 Cover inspection glass 11 Fan wheel 12 Motor 13 Nozzle assembly adjustment 14 Blast tube 15 Air adjustment 16 Air d...

Страница 5: ...er tube B30 Length of burner tube Measure B L 150 115 L Standard 222 187 L 350 315 Burner tube B40 N Standard 202 172 N 302 272 2 2 Dimensions B40A 175 382 B 372 108 108 220 281 303 195 400 126 114 B...

Страница 6: ...e net calorific value of 11 86 kWh kg for light oil has been used 7 0 9 0 2 5 3 5 1 0 2 0 TECHNICAL DATA 2 3 Output range and nozzles recommended B30 B40 2 4 Recommended nozzle Because of different bo...

Страница 7: ...E RME are and must be equipped with parts designed for this fuel This applies in particular to oil related parts such as the pump solenoid valve oil filter and hoses It is very important when carrying...

Страница 8: ...il quantity Raise the flue gas temperature by removing turbulators if any in the boiler Pump adjustment See separate description Maintenance The boiler burner should be examined regularly for any sign...

Страница 9: ...n the locking screw B and adjust the nozzle assembly to the desired position Lock the screw B again Air adjustment 0 10 Loosen the stop screw B and turn the knob along the scale to the desired positio...

Страница 10: ...doing any service switch off power at the main switch and cut off the oil supply A Service of burner head Open the cover plate and remove the connection hose by undoing screw A 1 Loosen or swing out t...

Страница 11: ...doing any service switch off power at the main switch and cut off the oil supply 1 Loosen or swing out the burner from the boiler 2 Loosen 2 fixing screws and withdraw the blast tube Service of burner...

Страница 12: ...12 Bentone B30A RME B40A RME 6 OIL CIRCUIT DIAGRAM 1 2 3 1 Nozzle 2 Safety valve 3 Oil pump...

Страница 13: ...ansformer Y1 Solenoid valve X1 Plug in contact burner X2 Plug in contact boiler Mains connection and fuses in accordance with local regulations 7 ELECTRIC EQUIPMENT 7 1 OIL BURNER CONTROL LOA21 LOA24...

Страница 14: ...attempt to re start 3 4 Operating position If the burner operation is interrupted by means of the main switch or the thermostat a new start takes place when the conditions in accordance with point 1 a...

Страница 15: ...09 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14 89 176 152 15 62 185 159 4 50 14 97 177...

Страница 16: ...3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 97 201 173 17 62 209 180 18 23 216 186 4 50 18 35 217 18...

Страница 17: ...efective oil burner control or flame monitor No oil supply Too great a pressure drop at brake plate Too strong draught prevents flame forming No spark Check and replace fuse as necessary Investigate c...

Страница 18: ...x normes et aux documents normatifs suivants et satisfont aux crit res applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suivantes 2004 108 EC...

Страница 19: ...the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...

Страница 20: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...

Отзывы: