Bentone B30A RME, B40A RME 

 

8.  NOZZLE TABLE

   

Gph

8

9

10

11

kg/h kW Mcal/h kg/h kW Mcal/h kg/h kW Mcal/h kg/h kW Mcal/h

0,40

1,33

16

13

1,41

17

14

1,49

18

15

1,56

18

16

0,50

1,66

20

17

1,76

21

18

1,86

22

19

1,95

23

20

0,60

2,00

24

20

2,12

25

22

2,23

26

23

2,34

28

24

0,65

2,16

26

22

2,29

27

23

2,42

29

25

2,54

30

26

0,75

2,49

29

25

2,65

31

27

2,79

33

28

2,93

35

30

0,85

2,83

33

29

3,00

36

31

3,16

37

32

3,32

39

34

1,00

3,33

39

34

3,53

42

36

3,72

44

38

3,90

46

40

1,10

3,66

43

37

3,88

46

39

4,09

48

42

4,29

51

44

1,20

3,99

47

41

4,24

50

43

4,47

53

46

4,68

55

48

1,25

4,16

49

42

4,40

52

45

4,65

55

47

4,88

58

50

1,35

4,49

53

46

4,76

56

48

5,02

59

51

5,27

62

54

1,50

4,98

59

51

5,29

63

54

5,58

66

57

5,85

69

60

1,65

5,49

65

56

5,82

69

59

6,14

73

63

6,44

76

66

1,75

5,82

69

59

6,18

73

63

6,51

77

66

6,83

81

70

2,00

6,65

79

68

7,06

84

72

7,45

88

76

7,81

93

80

2,25

7,49

89

76

7,94

94

81

8,38

99

85

8,78

104

89

2,50

8,32

99

85

8,82

105

90

9,31

110

95

9,76

116

99

2,75

9,15

108

93

9,71

115

99

10,24

121

104

10,73

127

109

3,00

9,98

118

102

10,59

126

108

11,16

132

114

11,71

139

119

3,50

11,65

138

119

12,35

146

126

13,03

154

133

13,66

162

139

4,00

13,31

158

136

14,12

167

144

14,89

176

152

15,62

185

159

4,50

14,97

177

153

15,88

188

162

16,75

198

171

17,57

208

179

5,00

16,64

197

170

17,65

209

180

18,62

221

190

19,52

231

199

5,50

18,30

217

187

19,42

230

198

20,48

243

209

21,47

255

219

6,00

19,97

237

204

21,18

251

216

22,34

265

228

23,42

278

239

6,50

21,63

256

220

22,94

272

234

24,20

287

247

25,37

301

259

7,00

23,29

276

237

24,71

293

252

26,06

309

266

27,33

324

279

7,50

24,96

296

254

26,47

314

270

27,92

331

285

29,28

347

298

8,00

26,62

316

271

28,24

335

288

29,79

353

304

31,23

370

318

8,50

28,28

335

288

30,00

356

306

31,65

375

323

33,18

393

338

9,00

29,95

355

305

31,77

377

324

33,59

398

342

35,14

417

358

The table applies to oil EO1 with a viscosity of 4,4 mm2/s (cSt) with density 830 kg/m3.

Burner with preheater

Consider that on preheating the oil quantity is reduced by 5-20% depending on

 

- Rise in temperature at the nozzle

 

- Design of nozzle

 

- Capacity (high capacity - small difference)

 

- Expect the output from the burner to reduce by 10–20% when fuelled by FAME (RME) due to the lower energy 

content of the oil.

Pump pressure bar

Содержание B30A RME

Страница 1: ...Providing sustainable energy solutions worldwide 178 080 51 2015 03 11 Installation and maintenance instruction B30A RME B40A RME...

Страница 2: ......

Страница 3: ...3 GENERAL INSTRUCTIONS___________________________________ 7 4 MAINTENANCE OF OIL BURNER B30______________ 10 5 MAINTENANCE OF OIL BURNER B40______________ 11 6 OIL CIRCUIT DIAGRAM_____________________...

Страница 4: ...5 Ignition cable 6 Ignition transformer 7 Photo cell 8 Control box 9 Reset button 10 Cover inspection glass 11 Fan wheel 12 Motor 13 Nozzle assembly adjustment 14 Blast tube 15 Air adjustment 16 Air d...

Страница 5: ...er tube B30 Length of burner tube Measure B L 150 115 L Standard 222 187 L 350 315 Burner tube B40 N Standard 202 172 N 302 272 2 2 Dimensions B40A 175 382 B 372 108 108 220 281 303 195 400 126 114 B...

Страница 6: ...e net calorific value of 11 86 kWh kg for light oil has been used 7 0 9 0 2 5 3 5 1 0 2 0 TECHNICAL DATA 2 3 Output range and nozzles recommended B30 B40 2 4 Recommended nozzle Because of different bo...

Страница 7: ...E RME are and must be equipped with parts designed for this fuel This applies in particular to oil related parts such as the pump solenoid valve oil filter and hoses It is very important when carrying...

Страница 8: ...il quantity Raise the flue gas temperature by removing turbulators if any in the boiler Pump adjustment See separate description Maintenance The boiler burner should be examined regularly for any sign...

Страница 9: ...n the locking screw B and adjust the nozzle assembly to the desired position Lock the screw B again Air adjustment 0 10 Loosen the stop screw B and turn the knob along the scale to the desired positio...

Страница 10: ...doing any service switch off power at the main switch and cut off the oil supply A Service of burner head Open the cover plate and remove the connection hose by undoing screw A 1 Loosen or swing out t...

Страница 11: ...doing any service switch off power at the main switch and cut off the oil supply 1 Loosen or swing out the burner from the boiler 2 Loosen 2 fixing screws and withdraw the blast tube Service of burner...

Страница 12: ...12 Bentone B30A RME B40A RME 6 OIL CIRCUIT DIAGRAM 1 2 3 1 Nozzle 2 Safety valve 3 Oil pump...

Страница 13: ...ansformer Y1 Solenoid valve X1 Plug in contact burner X2 Plug in contact boiler Mains connection and fuses in accordance with local regulations 7 ELECTRIC EQUIPMENT 7 1 OIL BURNER CONTROL LOA21 LOA24...

Страница 14: ...attempt to re start 3 4 Operating position If the burner operation is interrupted by means of the main switch or the thermostat a new start takes place when the conditions in accordance with point 1 a...

Страница 15: ...09 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14 89 176 152 15 62 185 159 4 50 14 97 177...

Страница 16: ...3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 97 201 173 17 62 209 180 18 23 216 186 4 50 18 35 217 18...

Страница 17: ...efective oil burner control or flame monitor No oil supply Too great a pressure drop at brake plate Too strong draught prevents flame forming No spark Check and replace fuse as necessary Investigate c...

Страница 18: ...x normes et aux documents normatifs suivants et satisfont aux crit res applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suivantes 2004 108 EC...

Страница 19: ...the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...

Страница 20: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...

Отзывы: