9
Bentone
2.5 Recommended nozzle and pressure
Nozzle:
45° Solid/semisolid
60° Solid/semisolid
80° Solid/semisolid
Pump pressure
10 bar (8-25 bar)
depending on pump model
2.6 Burner installation
2.6.1 Hole patten
Make sure the hole pattern on the boiler is designed for burner flange.
Combustion
device
d
1
d
2
d
3
B 30
ø 110
M10
ø 160-200
Because of the various boiler types with varying furnace geometries and
furnace loads, it is impossible to commit to a certain scattering angle or a
specific distribution pattern.
It should be noted that the scattering angle and distribution pattern changes
with pump pressure.
d
1
d
2
d
3
!
*NB It is important that
the spark does not strike
against the brake plate or
nozzle
a
b
c
d
B30
3.5-4.0
7,0-9,0
2.0-3.0
5.0-6.0
2.4 Setting of brake plate and air flow
b
d
a
c
Содержание B 30 A2.2H
Страница 2: ...2 Bentone...
Страница 14: ...14 Bentone 4 Installation 4 1 Handling and lifting instruktion The lifting aid are available as spare parts...
Страница 38: ......
Страница 39: ......
Страница 40: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...