background image

11

 

Bentone 

Pump pressure bar

   

Gph

17

19

21

23

25

kg/h kW Mcal/h kg/h kW Mcal/h kg/h kW Mcal/h kg/h kW Mcal/h kg/h kW Mcal/h

1,00

4.85

57

49

5,13

61

52

5,40

64

55

5,65

67

58

5,89

70

60

1,10

534

63

54

5,64

67

57

5,93

70

60

6,21

74

63

6,47

77

66

1,20

5,82

69

59

6,16

73

63

6,47

77

66

6,77

80

69

7,06

84

72

1,25

6,07

72

62

6,41

76

65

6,74

80

69

7,05

84

72

7,35

87

75

1,35

6,55

78

67

6,93

82

71

7,28

86

74

7,62

90

78

7,94

94

81

1,50

7,27

86

74

7,69

91

78

8,08

96

82

8,46

100

86

8,82

105

90

1,65

8,01

95

82

8,47

100

86

8,90

105

91

9,31

110

95

9,71

115

99

1,75

8,49

101

87

8,98

106

92

9,44

112

96

9,88

117

101

10,30

122

105

2,00

9,71

115

99

10,26

122

105

10,79

128

110

11,29

134

115

11,77

140

120

2,25

10,92

130

111

11,55

137

118

12,14

144

124

12,70

151

129

13,25

157

135

2,50

12,13

144

124

12,83

152

131

13,49

160

138

14,12

167

144

14,72

175

150

2,75 13,35

158

136

14,11

167

144

14,84

176

151

15,53

184

158

16,19

192

165

3,00 14,56

173

148

15,39

182

157

16,18

192

165

16,93

201

173

17,65

209

180

3,50 16,99

201

173

17,96

213

183

18,89

224

193

19,77

234

202

20,61

244

210

4,00

19,42

230

198

20,53

243

209

21,59

256

220

22,59

268

230

23,56

279

240

4,50

21,84

259

223

23,09

274

235

24,28

288

248

25,41

301

259

26,49

314

270

5,00 24,27

288

247

25,65

304

262

26,98

320

275

28,24

335

288

29,44

349

300

5,50 26,70

317

272

28,22

335

288

29,68

352

303

31,06

368

317

32,38

384

330

6,00 29,13

345

292

30,79

365

314

32,38

384

330

33,89

402

346

35,33

419

360

6,50

31,55

374

322

33,35

395

340

35,07

416

358

36,70

435

374

38,26

454

390

7,00

33,98

403

347

35,92

426

366

37,77

448

385

39,53

469

403

41,21

489

420

7,50 36,41

432

371

38,49

456

392

40,47

480

413

42,35

504

434

44,16

524

450

8,00 38,80

460

396

41,05

487

419

43,17

512

440

45,18

536

461

47,10

559

480

8,50 41,26

489

421

43,62

517

445

45,87

544

468

48,00

569

489

50,05

594

510

9,00

43,69

518

446

46,18

548

471

48,57

576

495

50,83

603

518

52,99

628

540

9,50 46,11

547

470

48,75

578

497

51,26

608

523

53,65

636

547

55,93

663

570

10,00

47,11

559

480

51,32

609

523

53,96

640

550

56,47

670

576

58,88

698

600

11,00

53,40

633

545

56,45

669

576

59,36

704

605

62,12

737

633

64,77

768

660

12,00

58,25

691

594

61,58

730

628

64,76

768

660

67,77

804

691

70,66

838

721

14,00 67,96

806

693

71,84

852

733

75,55

896

770

79,09

938

806

82,43

978

841

16,00 77,67

921

792

82,11

974

837

86,34 1024

880

90,36 1072

921

94,20 1117

961

The table applies to oil with a viscosity of 4.4 mm 

2

/s at a density of 830 kg/m 

3.

.

Содержание B 30 A2.2H

Страница 1: ...Providing sustainable energy solutions worldwide 178 112 52 1 2019 08 19 Installation and maintenance instruction B 30 A2 2H...

Страница 2: ...2 Bentone...

Страница 3: ...r setting ___________________________ 17 5 Burner installation___________________________________ 18 5 1 Examples of basic setting B 30_____________________ 18 5 2 Setting values for nozzle assembly B...

Страница 4: ...elative humidity no condensation Temperature 20 to 60 C Check that the burner is compatible with the boiler s output range The label information on the rating plate refers to the burner s minimum and...

Страница 5: ...tch this must be equipped with a hatch opening switch connected to the burner s safety system When in operation the burner s noise level can exceed 85 dBA Use hearing protection The burner must not be...

Страница 6: ...h Change cleaning Brake plate 1 Year Change cleaning 3000h Change cleaning Motor 1 year 3000 hrs Cuppling chaft 1 year control change 3000h control change Fan wheel 1 Year Change when dirty unbalance...

Страница 7: ...303 188 415 200 108 160 190 35 1 4 J H I B C A D E F G 2 Technical data B 30A 2 2H The burner is intended for Light oil B10 heating oil biofuel blend as defined in DIN V51603 6 and is used for Water h...

Страница 8: ...nd B 30 180W 1 3A 230V 50Hz 5 F 230V 2 5A 50Hz 84 dBA 0 5 dBA 2 3 Working field B 30A2 4 5 15 0 kg h 55 175 kW 2 3 1 Electric Specification Burner correspond to IP 20 1 0 1 2 3 4 5 50 60 70 80 90 100...

Страница 9: ...e d1 d2 d3 B 30 110 M10 160 200 Because of the various boiler types with varying furnace geometries and furnace loads it is impossible to commit to a certain scattering angle or a specific distributio...

Страница 10: ...33 324 279 7 50 26 47 314 270 29 28 347 298 8 00 28 24 335 288 31 23 370 318 8 50 30 00 356 306 33 18 393 338 9 00 31 77 377 324 35 14 417 358 13 kg h kW Mcal h 3 61 43 37 4 24 50 43 4 67 55 48 5 09 6...

Страница 11: ...9 268 230 23 56 279 240 4 50 21 84 259 223 23 09 274 235 24 28 288 248 25 41 301 259 26 49 314 270 5 00 24 27 288 247 25 65 304 262 26 98 320 275 28 24 335 288 29 44 349 300 5 50 26 70 317 272 28 22 3...

Страница 12: ...t button 8 Electric panel 9 Cover inspection glass 10 Switch I II 11 Switch I 0 12 Fan wheel 13 Motor 14 Nozzle assembly adjustment 15 Blast tube 16 Photo cell 17 Adjustment device 18 Indication air d...

Страница 13: ...ntenance 3 1 1 Installation and maintenance instructions The maintenance instructions supplied with the burner must be kept at an easily accessible location in the boiler room 3 1 2 Instructions The u...

Страница 14: ...14 Bentone 4 Installation 4 1 Handling and lifting instruktion The lifting aid are available as spare parts...

Страница 15: ...aning filters are recommended for oils of a higher viscosity or oils that contain significant impurities Oil affected parts shall be selected in materials that are capable of withstanding the medium s...

Страница 16: ...on all burner pipes This allows any drops of oil to run out 8 Insulate between the burner and boiler door to reduce radiated heat 9 Install the burner body on the flange 10 Lock the burner body using...

Страница 17: ...w Load I 2 Loosen the screw A turn the damper to the desired position and retighten the screw A Step 2 3 Set the control switch S2 to High Load II 4 Use a hex key to screw the socket B in to decrease...

Страница 18: ...o the installation in question and the fuel used at the time Basic settings The setting value for 150 kW according to default settings tables Refer to 6 2 for the correct settings procedure Nozzle ass...

Страница 19: ...0 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 Prior to commissioning the basic settings of the burner can be set in accordance with the diagram See under Basic settings Note that it is simply a matter...

Страница 20: ...lectrodes see technical data 8 If necessary replace the ignition electrodes 9 Fit the burner body and the burner flange together and secure with the nut G 10 Open the boiler spectacle flange to access...

Страница 21: ...air dampers Removal and installation 1 Switch off the mains power 2 Note the position of the air damper and loosen the actuator locking screw H 3 Loosen the screws L securing the air damper 4 Set the...

Страница 22: ...test run and check combustion 2 6 3 1 Replacing the drive shaft Removal and installation 1 Make sure the power to the burner is switched off 2 Detach the electrical panel 3 Disconnect the motor s ele...

Страница 23: ...It is important that the pump shaft splines align correctly in the pump coupling 6 Connect hoses connection pipes and electrical cables 7 Turn on the mains power 8 Bleed the pump start the burner and...

Страница 24: ...bration level are 5 0 mm s Check all bolts and nuts for correct torque Check fan wheel for damage and contamination Change when dirty unbalanced Check motor bearings If worn change motor bearings Use...

Страница 25: ...ty range 2 12 mm2 s Pressure range 8 15 bar Rated voltage of coil 220 240V 50 60 Hz Oil temperature max 60 C Components 1 Suction line G 1 4 2 Return plug 3 Nozzle outlet G 1 8 Stage 2 and stage 1 4 P...

Страница 26: ...e operation by pass plug removed and return plugged the oil which does not go through the nozzle lines is returned directly to the gear inlet and the suction line flow is equal to the sum of the 2 noz...

Страница 27: ...150 16 56 141 150 11 41 105 150 31 81 150 150 26 69 148 150 19 66 150 150 13 48 122 150 36 94 150 150 31 81 150 150 22 75 150 150 16 55 139 150 42 108 150 150 35 92 150 150 d mm 35 45 55 65 75 95 60 7...

Страница 28: ...lculated values where the pipe dimensions and oil velocity have been matched so that tur bulences will not occur Such tur bulences will result in increased pressure losses and in acoustic noise in the...

Страница 29: ...es may be hot When servicing oil bearing components check for oil leakage when the burner is commissioned after servicing 7 1 3 Check oil line seals Once the burner has been installed and commissioned...

Страница 30: ...the gasket seal pump Removal and installation 1 Disconnect hoses oil pipes and electrical cables 2 Loosen the pump screw J 3 Loosen the gasket seal s locking rings 4 Remove the old gasket seal 2 5 In...

Страница 31: ...same wiring as the existing component or the specified alternative arrangement 5 Turn on the mains power 6 Check the function of the new component 7 Start the burner Check combustion Note When servici...

Страница 32: ...32 Bentone 165 105 25 9 Oil burner control 9 1 Wiring diagram LOA 21 LOA24 LOA44 A DC Bl Svart LMO QRB 11 12 Blue Blau Bleue Black Schwarz Noir A1...

Страница 33: ...e this time limit the control cuts out If for some reasons the flame disappears after this time limit the burner will make an attempt to re start 4 Full load thermostat ON 1 The ignition spark goes ou...

Страница 34: ...ent light Check high voltage wiring and ignition electrodes Check preheater function Symptom Burner does not start Burner pre ventilates Burner stops Causes Fuse blown Boiler thermostat has not reset...

Страница 35: ...ht Adjust the burner Check preheater function Adjust the preheater s set operating temperature Ensure that the new oil s physical parame ters are within the limits for which the burner is designed If...

Страница 36: ...Address Test performed by Postal address Company name Tel no Boiler Type Make Power kW Bentone Burner Type Model Serial no Fuel Step 1 Step 2 Step 3 Draught in fireplace Fan Press mbar Filter smoke nu...

Страница 37: ...perature If the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main swi...

Страница 38: ......

Страница 39: ......

Страница 40: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...

Отзывы: